CDN 504-sym / CDN 508-sym, Signal 4/8-Line, Surge and EFT/burst, Coupling Decoupling Network

Designed for applying the impulse output voltage of the Combination Wave Generator to interconnection lines of the equipment under test, acc. to IEC 61000-4-5, Fig10.

Data Sheet

SPECIFICATIONS

CDN 504/ 508 symmetrical

  

 


Coupling-/Decoupling Network 

   

 

 

 

  • Rated voltage 80V=

 

 

  • Surge: 5.0 kV, 1.2/50 μs

 

 

  • Surge: 5.0 kV, 10/700 μs

 

 

  • Coupling Impedance, selectable

 

 

According to

 

IEC 61000-4-5

 

 

 

Designed for applying the impulse output voltage of the Combination Wave Generator to interconnection lines of the equipment under test, acc. to IEC 61000-4-5, Fig10.

 

 

The coupling/decoupling network CDN 504 /508 essentially consists of a current compensated decoupling inductor, L1 – L4/L8, and a set of coupling impedances to be inserted in the coupling path.

 

 

Technical specification:

CDN 504

CDN 508

Rated voltage

80 V=

Rated current

1A

Max. test voltage

5.0 kV,1.2/50µs,10/700 µs

Max. test current

2,5 kA, 8/20µs

Coupling Impedance, selectable:

R1 – R4

25W

R1 – R8

Rcpl1 - Rcpl4

135W

295W

Rcpl1 - Rcpl8

V1 – V4

over-voltage prot. 90V

V1 – V8

Decoupling inductors, current compensated

L1 – L4

20 mH, pair

L1 – L8

Dimensions: 19"-cabinet W * H * D

450*180*360mm³

Weight

 

9.5 kg

 

 

 

 

Accessories

CDN 508

 

1 HV-IN connecting cable with 4 mmÆ connectors, 1 GND-connecting cable, yellow/green, connecting plugs 19 mm, connecting plugs 38 mm.

OTHER PRODUCTS IN THE SAME CATEGORY: