Designed for applying the impulse output voltage of the Combination Wave Generator to interconnection lines of the equipment under test, acc. to IEC 61000-4-5, Fig10.
PARTNER:
MARKETS:
TEST STANDARDS:
CDN 504/ 508 symmetrical
|
|
|
|
According to |
|
IEC 61000-4-5 |
|
Designed for applying the impulse output voltage of the Combination Wave Generator to interconnection lines of the equipment under test, acc. to IEC 61000-4-5, Fig10.
The coupling/decoupling network CDN 504 /508 essentially consists of a current compensated decoupling inductor, L1 – L4/L8, and a set of coupling impedances to be inserted in the coupling path.
Technical specification: |
CDN 504 |
CDN 508 |
||
Rated voltage |
80 V= |
|||
Rated current |
1A |
|||
Max. test voltage |
5.0 kV,1.2/50µs,10/700 µs |
|||
Max. test current |
2,5 kA, 8/20µs |
|||
Coupling Impedance, selectable: |
R1 – R4 |
25W |
R1 – R8 |
|
Rcpl1 - Rcpl4 |
135W |
295W |
Rcpl1 - Rcpl8 |
|
V1 – V4 |
over-voltage prot. 90V |
V1 – V8 |
||
Decoupling inductors, current compensated |
L1 – L4 |
20 mH, pair |
L1 – L8 |
|
Dimensions: 19"-cabinet W * H * D |
450*180*360mm³ |
|||
Weight |
|
9.5 kg |
|
Accessories |
CDN 508 |
|
|