FP-COMB 32, Combined Automatic 3-Phase Coupling / Decoupling Network

FP-COMB 32

  • Voltage 480V AC & DC
  • Current 32 AMPs
  • Automatic Switching Surge, EFT, Ringwave
  • IEC & ANSI Coupling

FP-COMB-32 CDN Data Sheet

SPECIFICATIONS

FP-COMB 32, Combined Automatic 3-Phase Coupling / Decoupling Network

The FP-COMB 32 coupling/decoupling network – for Surge Combination Wave, Ring Wave, and EFT/Burst – is fully compliant with the standard requirements of IEC/EN 61000-4-4, IEC/EN 61000-4-5 and IEC/EN 61000-4-12.

The FP-COMB 32 is controlled by the AXOS5/AXOS8 expandable immunity test system(s). The CDN automatically changes the coupling paths, phase angles, and source impedance based on test parameters set by the user via the AXOS controller – depending on the standard and coupling mode.

The FP-COMB 32 was designed to reduce residual voltage levels by integrating the proper decoupling inductors for each type of CDN application to meet the requirements (with regard to voltage drop at the rated current). Apart from covering the EN/IEC 61000-4-5 standard, the FP-COMB 63/690-1 also covers tests to meet surge requirements outlined in ANSI/IEEE C62.41.

 

Features

  • Surge Combination Wave, 1.2/50 μs - 8/20 μs.
  • Ring Wave, 100 kHz.
  • Electrical Fast Transient (EFT) / Burst.
  • 7 kV impulse voltage for Surge Combination Wave and Ring Wave.
  • 5 kV impulse voltage for EFT/Burst.
  • Line voltage 480 V AC (phase-to-phase) / DC.
  • 32 A EUT current for each phase.
  • Phase angle synchronization for each path.
  1. All in One – Combined CDN for Surge Combination Wave, Ring Wave, and EFT / Burst.
  2. Easy to use – LEDs indicate active mode and coupling path.
  3. Automated – Automatic selection of surge impedance.
  4. Remote controlled – Fully remote controlled by the AXOS5 / AXOS8.

Application

  • Single & three phase power line systems
  • IEC/EN 61000-4-4 Edition 3
  • IEC/EN 61000-4-5 Edition 3
  • IEC/EN 61000-4-12 Edition 3
  • ANSI C62.41 & C62.45
  • Many IEC & EN product standards

 

 

 

FP-COMB 63/690-1 SPECIFICATIONS
COUPLING  
CDN Inputs Banana socket front panel 5 connectors
CDN Outputs Banana socket front panel 5 connectors
Waveforms EFT / Burst - IEC / EN 61000-4-4 Ed.3
Surge Combination Wave - IEC / EN 61000-4-5 Ed.3
Ring Wave - IEC / EN 61000-4-12 Ed.3
Maximum EFT / Burst Input Voltage 5 kV
Maximum Surge Combination Wave Input Voltage 7 kV
Maximum RIngg Wave Input Voltage 7 kV
Coupling Path Selection Automatic IEC + ANSI
Synchronization 10 V to 690 V input voltage
0° to 359°, step 1°
Sync. On coupling path, output BNC rear panel
DECOUPLING  
Voltage AC Up to 480 V
50/60 Hz, 16,7Hz, DC
Nominal Current 32 A
EFT / Burst Input Voltage Range 0.2 kV – 5 kV
Surge Combination Wave Input Voltage Range 0.2 kV – 7 kV
Ring Wave Input Voltage Range 0.2 kV – 7 kV
Coupling Path Selection Automatic
Synchronization 10 V to 690 V input voltage
0° to 359°, step 1°
INTERFACE  
Extension Connector
(37 pol. Sub-D connector)
Interface cable to AXOS
LEDs Indication of coupling path Power ON LED
CDN active LED, overtempt
DIMENSIONS AND WEIGHT  
Dimensions  
Weight  

1 Depending on the voltage and frequency.

Included accessories 

  • FP-COMB 32
  • AC mains cable country-specific
  • EUT mains cable 32A
  • EUT mains adaptor 32A
  • Calibration certificate
  • Surge cable to AXOS
  • EFT/Burst cable to AXOS
  • User manual

 

Please visit our Rental Partners Transient Specialist and Advanced Test Equipment Corp.

 


 
OTHER PRODUCTS IN THE SAME CATEGORY:
Loading...