FP-COMB 63 / 125 / 200 A - 690 V AC + 1500 V DC Test Networks

One configured network for 690 V AC applications and high-voltage DC testing.

Specify the Haefely FP-COMB /1500-1 with its AC option for both AC and DC test programs. The combined configuration supports 1500 V DC and AC operation up to 1000 Vrms, including commonly specified 690 V AC systems. Choose 63, 125 or 200 A; retain the DC capability while adding the AC coupling and synchronization functions.

63 / 125 / 200 A | 7 kV surge and ring wave | 5 kV EFT/burst

PARTNER:

Select Options/Sizes:

FP-COMB 63 / 125 / 200 A - 690 V AC Data Sheet V2026.06

FP-COMB 63 / 125 / 200 A - 1500 V DC and AC Option Data Sheet V2026.06

SPECIFICATIONS

HAEFELY · AUTOMATIC TRANSIENT CDNs

FP-COMB 63 / 125 / 200 A - 1500 V DC Coupling / Decoupling Networks

High-voltage DC transient testing with a path to AC capability.

1500 V DC

DC rating depends on load inductance

63 / 125 / 200 A

Three current ratings for each configuration.

7 kV / 5 kV

7 kV surge and ring-wave input; 5 kV EFT/burst input.

Haefely FP-COMB 1500-1 coupling decoupling network cabinet
Representative FP-COMB 1500-1 cabinet. Configuration and installed options vary; AXOS is separate.

Automated surge, ring-wave and EFT/burst testing

The Haefely FP-COMB /1500-1 family couples surge combination wave, ring wave and EFT/burst disturbances onto DC power circuits up to 1500 V. Select a 63, 125 or 200 A network to match the EUT. Add the AC option when your test program also needs single- or three-phase AC coverage.

Three transient tests

Surge combination wave: 1.2/50 µs voltage and 8/20 µs current. Ring wave: 100 kHz. EFT/burst: IEC/EN 61000-4-4.

Automatic test routing

AXOS selects coupling paths and source impedance for the chosen IEC or ANSI test mode. AC configurations also synchronize the phase angle.

Decoupling and indication

Application-specific decoupling inductors reduce residual voltage while addressing voltage drop at rated current. LEDs show active coupling path, power, CDN activity and overtemperature.

Compare all AC, DC and AC+DC versions

Compare four FP-COMB families covering all ten configurations
Product familyCurrent optionsAC voltageDC voltage¹Configuration
FP-COMB 32 32 A 480 V AC 480 V DC AC + DC included
FP-COMB /690-1 63 / 125 / 200 A 690 V AC 63 A: 110 V DC
125 / 200 A: 200 V DC
AC included; limited DC
FP-COMB /1500-1 — DC 63 / 125 / 200 A Requires AC option 1500 V DC Upgradeable to AC + DC
FP-COMB /1500-1 — AC + DC 63 / 125 / 200 A Up to 1000 Vrms
Includes 690 V AC
1500 V DC Matching AC option fitted

All versions: 7 kV surge and ring-wave input; 5 kV EFT/burst input. Available tests depend on the AXOS generator and installed modules. AC-equipped versions support single- and three-phase applications.

¹ For /690-1 and /1500-1 networks, DC voltage capability depends on load inductance. /690-1 AC current capability depends on voltage and frequency. AC+DC is a /1500-1 network with its matching AC option. The 63, 125 and 200 A entries are separate model choices, not selectable current upgrades. Detailed model specifications and weights appear below and on the linked family pages.

Technical specifications

FP-COMB 1500 V DC family specifications
Specification63 A125 A200 A
Model FP-COMB 63/1500-1 FP-COMB 125/1500-1 FP-COMB 200/1500-1
Nominal DC current 63 A 125 A 200 A
DC voltage¹ Up to 1500 V Up to 1500 V Up to 1500 V
AC voltage AC operation requires configuration confirmation / AC option; see note below AC operation requires configuration confirmation / AC option; see note below AC operation requires configuration confirmation / AC option; see note below
Nominal AC current 63 A with AC option 125 A with AC option 200 A with AC option
AC frequencies 50 / 60 Hz and 16.7 Hz with AC option 50 / 60 Hz and 16.7 Hz with AC option 50 / 60 Hz and 16.7 Hz with AC option
CDN inputs 5 × 10 mm sockets plus 2 × 10 mm DC sockets 5 × 10 mm sockets plus 2 × 10 mm DC sockets 5 × 10 mm sockets plus 2 × 10 mm DC sockets
CDN outputs 5 × 10 mm sockets, front panel 5 × 10 mm sockets, front panel 5 × 10 mm sockets, front panel
Input and output cable cross-section 16 mm² 50 mm² 50 mm²
EFT/burst input range / maximum 0.2-5 kV / 5 kV 0.2-5 kV / 5 kV 0.2-5 kV / 5 kV
Surge combination-wave input range / maximum 0.2-7 kV / 7 kV 0.2-7 kV / 7 kV 0.2-7 kV / 7 kV
Ring-wave input range / maximum 0.2-7 kV / 7 kV 0.2-7 kV / 7 kV 0.2-7 kV / 7 kV
Coupling / decoupling path selection Automatic; IEC + ANSI coupling modes Automatic; IEC + ANSI coupling modes Automatic; IEC + ANSI coupling modes
Synchronization input 10-1000 Vrms; AC option for AC operation 10-1000 Vrms; AC option for AC operation 10-1000 Vrms; AC option for AC operation
Phase angle and synchronization output 0°-359° in 1° steps; synchronization on coupling path; rear BNC output (AC option) 0°-359° in 1° steps; synchronization on coupling path; rear BNC output (AC option) 0°-359° in 1° steps; synchronization on coupling path; rear BNC output (AC option)
AXOS control interface 37-pin Sub-D extension connector / interface cable to AXOS 37-pin Sub-D extension connector / interface cable to AXOS 37-pin Sub-D extension connector / interface cable to AXOS
LED indications Coupling path, power on, CDN active, overtemperature Coupling path, power on, CDN active, overtemperature Coupling path, power on, CDN active, overtemperature
Dimensions, W × D × H 552 × 800 × 1605 mm 552 × 800 × 1605 mm 552 × 800 × 1605 mm
Overall dimensions, W × D × H 552 × 852 × 1754 mm; includes rack rollers, crane hook and power plug 552 × 852 × 1754 mm; includes rack rollers, crane hook and power plug 552 × 852 × 1754 mm; includes rack rollers, crane hook and power plug
Weight without AXOS 260-290 kg 275-305 kg 275-305 kg

¹ DC voltage depends on load inductance. Weight depends on selected options. The datasheet feature list identifies 1000 Vrms at DC−/DC+, while its AC technical ratings and phase synchronization are conditional on the AC option. Specify the intended connection and installed options when ordering.

Standards and generator compatibility

  • IEC/EN 61000-4-4, Edition 3: EFT/burst
  • IEC/EN 61000-4-5, Edition 3: surge combination wave
  • IEC/EN 61000-4-12, Edition 3: ring wave
  • ANSI/IEEE C62.41 and ANSI C62.45 applications

The networks are controlled by AXOS 5 or AXOS 8. The /1500-1 datasheet states compliance with AXOS 8. Use an appropriately equipped AXOS 8 for 7 kV surge/ring-wave testing; compatibility with AXOS 5 does not add missing waveforms or raise its generator output rating.

Included components

  • One FP-COMB network in the selected 63, 125 or 200 A rating
  • Five 3 m AC mains cables with 10 mm plugs and open ends, as listed in the DC datasheet.
  • One 5 m ground cable
  • Five 3 m EUT mains cables with 10 mm plugs and open ends
  • 10 A AC mains cable
  • Calibration certificate
  • Surge cable to AXOS
  • EFT/burst cable to AXOS
  • Surge calibration adapter
  • EFT/burst calibration adapter
  • User manual
AXOS generator/controller and EUT power source are separate system equipment. The CDN couples and decouples the applied disturbances; it does not replace the generator or EUT supply.

Configuration and upgrade options

The AC+DC configuration uses the /1500-1 DC network plus its matching AC option. The AC option adds three-phase AC operation for common 690 V applications, with AC capability up to 1000 Vrms. Confirm the required upgrade arrangement and installation with Haefely for an existing unit. A multiple-current-level switch supports lower-current testing; the datasheet does not list its switch positions or describe a current-rating upgrade.

  • AC option for the matching 63, 125 or 200 A DC network
  • Optional integrated EUT main-power switch: DC-only version (described as 2-phase in the datasheet) or AC/DC version (described as 4-phase)
  • External emergency-off / Safe Box
  • Accredited calibration with certificate (optional; standard calibration certificate is included)

Related test equipment

Haefely AXOS 5 compact immunity test system

AXOS 5 compact immunity test system

AXOS control with up to 5 kV surge and EFT/burst capability, depending on installed modules. Select AXOS 8 when 7 kV surge or ring-wave testing is required.

Haefely AXOS 8 expandable immunity test system

AXOS 8 expandable immunity test system

Configure the surge, ring-wave and EFT modules needed for the FP-COMB application. View generator specifications and available modules.

Documentation

Download the 1500 V DC / AC-option datasheet (V2026.06)
OTHER PRODUCTS IN THE SAME CATEGORY: