Approx. 1 mT | Coupling-clamp tip | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us delay
P12t combines TTL-synchronized magnetic disturbance generation with a tip that uses the coupling-clamp principle. It is intended for detailed susceptibility analysis while a circuit is in a specific operating condition. Use a DUT signal or external logic as the trigger and compare the failure response as the source position or circuit design changes. The set includes cable, power supply, case and manual.
MARKETS:
CATEGORIES:
TEST STANDARDS:
P12t combines TTL-synchronized magnetic disturbance generation with a tip that uses the coupling-clamp principle. It is intended for detailed susceptibility analysis while a circuit is in a specific operating condition. Use a DUT signal or external logic as the trigger and compare the failure response as the source position or circuit design changes. The set includes cable, power supply, case and manual.
| Feature | Engineering benefit / use |
|---|---|
| Coupling geometry | The P12t tip follows the coupling-clamp principle, distinguishing it from P11t even though their headline electrical values match. |
| Synchronization | Use the 5 V TTL SMB input to synchronize magnetic disturbances with DUT activity or external logic. |
| Timing | The published trigger delay is 3 us and the frequency range is single pulse to 10 kHz. |
| Parameter | Specification |
|---|---|
| External trigger input | SMB, male, jack; 5 V TTL |
| Generated magnetic flux density | ca. 1 mT |
| Pulse parameter / Frequency | single ... 10 kHz |
| Pulse parameter / Trigger-pulse delay | 3 us |
| Pulse parameter / Supply voltage | 6.5 V ... 15 V |
| Component | Parameter | Specification |
|---|---|---|
| P12t | Generator voltage | 400 V |
| P12t | External trigger input | SMB, male, jack; 5 V TTL |
| P12t | Generated magnetic flux density | ca. 1 mT |
| P12t | Pulse parameter / Pulse width | 2 ns ... 8 ns |
| P12t | Pulse parameter / Frequency | single ... 10 kHz |
| P12t | Pulse parameter / Polarity | switchable |
| P12t | Pulse parameter / Trigger-pulse delay | 3 us |
| P12t | Pulse parameter / Supply voltage | 6.5 V - 15 V |
| P12t | Pulse parameter / Current input | 50 mA @ 6.5 V |
| P12t | Pulse parameter / Weight | 20 g |
| P12t | Pulse parameter / Sizes (L x W x H) | (125 x 24 x 20) mm |
| SMB-BNC 1 m | Weight | 25 g |
| SMB-BNC 1 m | Sizes (L x W x H) | 1 m |
6.5-15 V supply; power supply included. A powered DUT and a way to observe its functional response are required. The tools support engineering diagnosis; they do not replace the complete standardized compliance test setup.
| Document | |
|---|---|
| P12t set - Datasheet | View PDF |
| Question | Answer |
|---|---|
| What is this product best suited to? | Choose the clamp-principle tip for a targeted magnetic coupling task. |
| What supporting equipment is needed? | 6.5-15 V supply; power supply included. A powered DUT and a way to observe its functional response are required. The tools support engineering diagnosis; they do not replace the complete standardized compliance test setup. |
| Does this establish compliance with IEC 61000-4-4 or IEC 61000-4-2? | These are development and diagnostic tools. Relating a local disturbance to an EFT/burst or ESD failure helps troubleshooting; formal compliance requires the applicable standardized generator, coupling method, test setup and procedure. |
Compare generation, coupling and detection tools. The kit pictures identify the complete sets. Product links below use the planned Absolute EMC product pages.
| Kit | Product / function | Key distinction | Required pulse source / power |
|---|---|---|---|
![]() |
E1 set Integrated generation and local E/H-field troubleshooting |
Approx. 0-1500 V pulses | 2 ns rise / 10 ns tail | 4 H-field + 5 E-field sources | 10 Mbps optical sensor | SGZ 21 included; 12 V / 200 mA |
![]() |
E2 set Programmable pulse generation and differential injection |
Up to 2.2 kV adjustable | 1.5 ns rise | Adjustable 1.5 kHz repetition | Both polarities | 50 Mbps optical sensor | TS 23 included; 24 V / 1 A DC |
![]() |
S2 set Transient magnetic-field sensing |
Active + passive H-field probes | 3 MSA 02 heads | Optical signal transfer | MSA 02: 1 AAA battery | SGZ 21 receiver documented; confirm E2 receiver arrangement |
![]() |
P1 set Battery-powered E/H-field injection |
3 generators: P11 + P12 + P21 | Approx. 1 mT H-field / 100 kV/m E-field | Single pulse or 5 kHz | 1.5 V AAA | 1.5 V AAA supply; single pulse / 5 kHz |
![]() |
P23 set Fine-tip capacitive pulse injection |
1.2 kV generator voltage | 10 pF coupling | 1.8-10 ns rise | Single pulse or 5 kHz | 1.5 V AAA | 1.5 V AAA supply; single pulse / 5 kHz |
![]() |
P11t set TTL-synchronized magnetic pulse injection |
Approx. 1 mT | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us trigger delay | 6.5-15 V supply | 6.5-15 V supply; power supply included |
![]() |
P12t set TTL-synchronized clamp-style magnetic coupling |
Approx. 1 mT | Coupling-clamp tip | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us delay | 6.5-15 V supply; power supply included |
![]() |
H2 set External-generator E/H-field coupling |
6 field sources: 3 H + 3 E | Up to 4.4 kV source supply | External EFT/burst generator required | External EFT/burst generator; source limit 4.4 kV |
![]() |
H3 set Extended external-generator E/H-field coupling |
9 field sources: 4 H + 5 E | High-voltage SMB connections | SHV or Fischer cable choice | External generator required | External EFT/burst generator; observe each source rating |
![]() |
PT4 set Potential-free pulse injection plus E/H-field coupling |
4.5 kV maximum burst input | 1:1 transformer | 500 V output dielectric strength | H- and E-field sources | External EFT/burst generator; transformer maximum 4.5 kV |
![]() |
H4-IC set Small-area magnetic field coupling |
Up to 200 mT | 2.54 mm2 resolution | 1.8 mm diameter head | 0-66 MHz | 4 kV maximum burst | External EFT/burst generator; 4 kV maximum burst input |
![]() |
H5-IC set Magnetic field coupling with BS 06DU-s |
Up to 150 mT | 5 x 6 mm head | 0-560 MHz | 4 kV maximum burst | 15 g source | External EFT/burst generator; 4 kV maximum burst input |
![]() |
BD 11 Cable-transient detection and event indication |
Adjustable sensitivity | LED + relay + optical outputs | 20 m maximum fiber | 2 AAA batteries | 88 x 85 x 32 mm | Two 1.5 V AAA batteries |