Langer H2 set | EFT/Burst Electric and Magnetic Field Source Set

6 field sources: 3 H + 3 E | Up to 4.4 kV source supply | External EFT/burst generator required

H2 adapts an external EFT/burst generator for localized PCB immunity analysis. Three magnetic and three electric field sources provide different tip geometries for probing components, traces and IC pins. The set includes a high-voltage connection cable, case and manual. Confirm the generator-side SHV or Fischer connector when ordering.

TEST STANDARDS:

Select Options/Sizes:

H2 set - Datasheet

SPECIFICATIONS

H2 set - EFT/Burst Electric and Magnetic Field Source Set

H2 adapts an external EFT/burst generator for localized PCB immunity analysis. Three magnetic and three electric field sources provide different tip geometries for probing components, traces and IC pins. The set includes a high-voltage connection cable, case and manual. Confirm the generator-side SHV or Fischer connector when ordering.

H2 set, Field Sources

Features and application benefits

FeatureEngineering benefit / use
Six sources BS 02-h, BS 04DB-h and BS 05DB-h provide H-field coupling; ES 00-h, ES 02-h and ES 05D-h provide E-field coupling.
External pulse supply The sources connect through high-voltage-resistant SMB connections to a compatible EFT/burst generator. The set is not a standalone generator.
Connector selection Specify the generator-side connector at ordering. Use a purpose-built high-voltage cable; an ordinary RF SMB cable is not a substitute.

Technical specifications

ParameterSpecification
Field source count 6 (3 H / 3 E)
Pulse source External EFT/burst generator required
Source interface High-voltage-resistant SMB
Generator-side cable choice SHV or Fischer S103A023; confirm before ordering
Maximum field-source supply voltage 4.4 kV

Included components

PhotoQty.ItemFunction / key specifications
BS 02-h, Magnetic Field Source 1x BS 02-h Magnetic Field Source
Probe head dimensions: > 5 cm
Weight: 18 g
BS 04DB-h, Magnetic Field Source 1x BS 04DB-h Magnetic Field Source
Probe head dimensions: 1 mm - 3 mm
BS 05DB-h, Magnetic Field Source 1x BS 05DB-h Magnetic Field Source
Probe head dimensions: 1 mm - 3 mm
ES 00-h, E-Field Source 1x ES 00-h E-Field Source
ES 02-h, E-Field Source 1x ES 02-h E-Field Source
ES 05D-h, E-Field Source 1x ES 05D-h E-Field Source
HV SHV-SMB 1 m, High-Voltage Cable, SHV SMB 1 selected cable High-voltage connection cable Choose HV SHV-SMB 1 m (SHV) or HV FI-SMB 1 m (Fischer). Both may be ordered; see the pictured alternatives below.
  1x H case System Case
  1x H3 m H3 Set User Manual

Included component specifications

ComponentParameterSpecification
BS 02-h Probe head dimensions > 5 cm
BS 02-h Weight 18 g
BS 04DB-h Probe head dimensions 1 mm - 3 mm
BS 05DB-h Probe head dimensions 1 mm - 3 mm
HV SHV-SMB 1 m Max. Burst-voltage 4,4 kV
HV SHV-SMB 1 m Sizes (L x W x H) 1,20 m

Application and kit views

ImageWhat it shows
Application with magnetic field source BS 04DB-h Application with magnetic field source BS 04DB-h
Application with E-field source ES 05D-h Application with E-field source ES 05D-h
Scope of delivery H2 set Scope of delivery H2 set

System requirements and ordering notes

External EFT/burst generator; source limit 4.4 kV. The pulse generator and DUT are not included. Match the cable to the generator and observe the lowest voltage rating of every connected component.

Recommended products and accessories

PhotoProductSpecifications / purposeOrdering
HV SHV-SMB 1 m, High-Voltage Cable, SHV SMB HV SHV-SMB 1 m 1 m purpose-built high-voltage cable; SHV generator-side connector to high-voltage-resistant SMB. Select the connector to match the generator. Choose as the set cable, or add alongside the other cable
HV FI-SMB 1 m, High-Voltage Cable, Fischer-SMB HV FI-SMB 1 m 1 m purpose-built high-voltage cable; Fischer S103A023 generator-side connector to high-voltage-resistant SMB. Select the connector to match the generator. Choose as the set cable, or add alongside the other cable

Choose HV SHV-SMB 1 m or HV FI-SMB 1 m as the connection cable. You may order both when you need SHV and Fischer connections. Both cables are not automatically included; confirm the selected configuration and price in the quotation.

Datasheets

DocumentPDF
H2 set - Datasheet View PDF

Practical questions

QuestionAnswer
What is this product best suited to? Add six local coupling tools to an existing EFT/burst generator.
What supporting equipment is needed? External EFT/burst generator; source limit 4.4 kV. The pulse generator and DUT are not included. Match the cable to the generator and observe the lowest voltage rating of every connected component.
Does this establish compliance with IEC 61000-4-4 or IEC 61000-4-2? These are development and diagnostic tools. Relating a local disturbance to an EFT/burst or ESD failure helps troubleshooting; formal compliance requires the applicable standardized generator, coupling method, test setup and procedure.

PCB immunity selection guide

Compare generation, coupling and detection tools. The kit pictures identify the complete sets. Product links below use the planned Absolute EMC product pages.

KitProduct / functionKey distinctionRequired pulse source / power
E1 set, Immunity Development System E1 set
Integrated generation and local E/H-field troubleshooting
Approx. 0-1500 V pulses | 2 ns rise / 10 ns tail | 4 H-field + 5 E-field sources | 10 Mbps optical sensor SGZ 21 included; 12 V / 200 mA
E2 set, TS 23 Immunity Development System E2 set
Programmable pulse generation and differential injection
Up to 2.2 kV adjustable | 1.5 ns rise | Adjustable 1.5 kHz repetition | Both polarities | 50 Mbps optical sensor TS 23 included; 24 V / 1 A DC
S2 set, Magnetic Field Probes for E1 S2 set
Transient magnetic-field sensing
Active + passive H-field probes | 3 MSA 02 heads | Optical signal transfer | MSA 02: 1 AAA battery SGZ 21 receiver documented; confirm E2 receiver arrangement
P1 set, Mini Burst Field Generators P1 set
Battery-powered E/H-field injection
3 generators: P11 + P12 + P21 | Approx. 1 mT H-field / 100 kV/m E-field | Single pulse or 5 kHz | 1.5 V AAA 1.5 V AAA supply; single pulse / 5 kHz
P23 set, Mini Burst Field Generator (E) P23 set
Fine-tip capacitive pulse injection
1.2 kV generator voltage | 10 pF coupling | 1.8-10 ns rise | Single pulse or 5 kHz | 1.5 V AAA 1.5 V AAA supply; single pulse / 5 kHz
P11t set, Mini Burst Field Generator (B, Trigger) P11t set
TTL-synchronized magnetic pulse injection
Approx. 1 mT | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us trigger delay | 6.5-15 V supply 6.5-15 V supply; power supply included
P12t set, Mini Burst Field Generator (B, Trigger) P12t set
TTL-synchronized clamp-style magnetic coupling
Approx. 1 mT | Coupling-clamp tip | 5 V TTL SMB trigger | Single pulse to 10 kHz | 3 us delay 6.5-15 V supply; power supply included
H2 set, Field Sources H2 set
External-generator E/H-field coupling
6 field sources: 3 H + 3 E | Up to 4.4 kV source supply | External EFT/burst generator required External EFT/burst generator; source limit 4.4 kV
H3 set, Field Sources H3 set
Extended external-generator E/H-field coupling
9 field sources: 4 H + 5 E | High-voltage SMB connections | SHV or Fischer cable choice | External generator required External EFT/burst generator; observe each source rating
PT4 set, EFT Generator Set PT4 set
Potential-free pulse injection plus E/H-field coupling
4.5 kV maximum burst input | 1:1 transformer | 500 V output dielectric strength | H- and E-field sources External EFT/burst generator; transformer maximum 4.5 kV
H4-IC set, EFT/Burst Magnetic Field Source H4-IC set
Small-area magnetic field coupling
Up to 200 mT | 2.54 mm2 resolution | 1.8 mm diameter head | 0-66 MHz | 4 kV maximum burst External EFT/burst generator; 4 kV maximum burst input
H5-IC set, EFT/Burst Magnetic Field Source H5-IC set
Magnetic field coupling with BS 06DU-s
Up to 150 mT | 5 x 6 mm head | 0-560 MHz | 4 kV maximum burst | 15 g source External EFT/burst generator; 4 kV maximum burst input
BD 11, H-Field Burst Detector BD 11
Cable-transient detection and event indication
Adjustable sensitivity | LED + relay + optical outputs | 20 m maximum fiber | 2 AAA batteries | 88 x 85 x 32 mm Two 1.5 V AAA batteries
OTHER PRODUCTS IN THE SAME CATEGORY: