2 MHz to 6 GHz | Scanner-mounted H-field mapping with a horizontal coil (300 μm)
Use this horizontal-coil microprobe to map magnetic fields around IC packages and fine PCB structures. The integrated preamplifier is supplied through the BT 706 bias tee. Use a compatible positioning system and the probe correction data for repeatable comparisons.
MARKETS:
CATEGORIES:
TEST STANDARDS:
Select Options/Sizes:
Use this horizontal-coil microprobe to map magnetic fields around IC packages and fine PCB structures. The integrated preamplifier is supplied through the BT 706 bias tee. Use a compatible positioning system and the probe correction data for repeatable comparisons.
| Parameter | Specification |
|---|---|
| Frequency coverage | 2 MHz to 6 GHz |
| Spatial resolution | 300 μm |
| Coil inner diameter | 500 μm |
See the Langer ICR microprobe selection guide for coil orientation, frequency coverage and spatial resolution across the family.
Langer demonstrates probe tip shapes, correction curves and time-domain measurements. The tutorial covers general probe technique.
Watch the Langer near-field probe tutorial on YouTube
| Photo | Kit | Probes included | Frequency coverage | Choose it for |
|---|---|---|---|---|
![]() |
Y.I.C. NFP Kit | 5 | 10 MHz to 14 GHz | Handheld EMI mapping with five E-field and H-field probes, camera tracking and EMViewer. Uses a compatible external spectrum analyzer. |
![]() |
LF1 set (this set) | 4 | 100 kHz to 50 MHz | Lower-frequency magnetic fields near power circuits |
![]() |
RF Basic set | 6 | 30 MHz to 3 GHz | General PCB survey and fine electric and magnetic troubleshooting |
![]() |
RF1 set | 4 | 30 MHz to 3 GHz | Close-range electric and magnetic troubleshooting |
![]() |
RF2 set | 4 | 30 MHz to 3 GHz | Magnetic survey and source tracing with four heads |
![]() |
RF3 mini set | 2 | 30 MHz to 3 GHz | Sub-millimeter magnetic source localization |
![]() |
RF4-E set | 2 | 30 MHz to 3 GHz | Electric-field coupling and switching-node investigations |
![]() |
XF1 set | 5 | 30 MHz to 6 GHz | Electric and magnetic PCB diagnostics through 6 GHz |
![]() |
SX1 set | 3 | 1 GHz to 10 GHz | Electric and magnetic diagnostics from 1 to 10 GHz |
![]() |
SX-R 20-1 set | 1 | 1 GHz to 20 GHz | Single magnetic probe for measurements through 20 GHz |
![]() |
HR1 set | 2 | Up to 40 GHz | Combined electric and magnetic coverage through 40 GHz |
![]() |
HR-E 40-1 set | 1 | Up to 40 GHz | Single electric-field probe for measurements up to 40 GHz (0.2 mm) |
![]() |
HR-R 8-1 set | 1 | Up to 40 GHz | Single magnetic-field probe for measurements up to 40 GHz |
![]() |
MFA 01 set | 3 | 1 MHz to 6 GHz | Handheld active magnetic microprobes (200 μm) |
![]() |
MFA 02 set | 2 | 1 MHz to 1 GHz | Handheld active magnetic microprobes (200 μm) |