EMScanner: 150 kHz- 8 GHz, 3.5mm Resolution,  EMC desktop scanner

EMScanner: 150 kHz- 8 GHz, 3.5mm Resolution, EMC desktop scanner

EMScannerR: 150 kHz- 8 GHz, 0.06mm resolution, EMC desktop scanner

EMScannerR: 150 kHz- 8 GHz, 0.06mm resolution, EMC desktop scanner

EMProbe: 9kHz- 18 GHz, 0.2mm resolution, EMC robotic scanner

EMProbe: 9kHz- 18 GHz, 0.2mm resolution, EMC robotic scanner

EMScannerR+: 150 kHz- 6 GHz, w/ Real-Time Spectrum Analyzer, EMC desktop scanner

EMScannerR+: 150 kHz- 6 GHz, w/ Real-Time Spectrum Analyzer, EMC desktop scanner

EMScanner+: 150 kHz- 6 GHz, w/ Real-Time Spectrum Analyzer, EMC desktop scanner

EMScanner+: 150 kHz- 6 GHz, w/ Real-Time Spectrum Analyzer, EMC desktop scanner

EMProbe-DBM-E6 — 6-Axis Robotic Near-Field EMI Diagnostics on the Bench

EMProbe-DBM-E6 — 6-Axis Robotic Near-Field EMI Diagnostics on the Bench

EMProbe CR5 - Custom Large-Reach Robotic EMI Scanning System

EMProbe CR5 - Custom Large-Reach Robotic EMI Scanning System

Langer ICS 105 | Compact IC workbench scanner

Langer ICS 105 | Compact IC workbench scanner

Langer FLS 106 IC | Large-area scanner with probe rotation

Langer FLS 106 IC | Large-area scanner with probe rotation

Langer FLS 106 PCB | Large-area three-axis PCB scanner

Langer FLS 106 PCB | Large-area three-axis PCB scanner

Langer Scanner and Scanner Probe Comparison Guide

Langer Scanner and Scanner Probe Comparison Guide

Langer LFS Scanner Probes | 100 kHz to 50 MHz

Langer LFS Scanner Probes | 100 kHz to 50 MHz

Products

EMScanner: 150 kHz- 8 GHz, 3.5mm Resolution, EMC desktop scanner

150 kHz to 8 GHz | External spectrum analyzer | 1,218-probe array

EMScanner helps engineers locate and compare PCB emission sources across a 316 x 218 mm scan area. A fixed array of 1,218 magnetic-field probes gives fast coverage, with 7.5 mm physical spacing and a manufacturer-stated 3.75 mm effective resolution. Use it with a compatible external spectrum analyzer and a PC running EMViewer.

EMScannerR: 150 kHz- 8 GHz, 0.06mm resolution, EMC desktop scanner

150 kHz to 8 GHz | External spectrum analyzer | Down to 0.06 mm

EMScannerR helps engineers locate and compare PCB emission sources across a 316 x 218 mm scan area. Its eight selectable resolution levels run from 7.5 mm down to 0.06 mm for detailed investigation of dense boards. Use it with a compatible external spectrum analyzer and a PC running EMViewer.

EMProbe: 9kHz- 18 GHz, 0.2mm resolution, EMC robotic scanner

Component-side scanning | Adjustable probe height | External analyzer

EMProbe automates a handheld near-field probe over the component side of a PCB or around a non-flat assembly. Program scan height and position in EMViewer, then acquire RF measurements with a compatible external spectrum analyzer. The compact arm is suited to repeatable bench investigations, with larger arm or extension configurations available for application-specific work.

EMScannerR+: 150 kHz- 6 GHz, w/ Real-Time Spectrum Analyzer, EMC desktop scanner

150 kHz to 6 GHz | Internal spectrum analyzer | Down to 0.06 mm

EMScannerR+ helps engineers locate and compare PCB emission sources across a 316 x 218 mm scan area. Its eight selectable resolution levels run from 7.5 mm down to 0.06 mm for detailed investigation of dense boards. The internal spectrum analyzer simplifies the measurement setup; a user PC runs EMViewer.

EMScanner+: 150 kHz- 6 GHz, w/ Real-Time Spectrum Analyzer, EMC desktop scanner

150 kHz to 6 GHz | Internal spectrum analyzer | 1,218-probe array

EMScanner+ helps engineers locate and compare PCB emission sources across a 316 x 218 mm scan area. A fixed array of 1,218 magnetic-field probes gives fast coverage, with 7.5 mm physical spacing and a manufacturer-stated 3.75 mm effective resolution. The internal spectrum analyzer simplifies the measurement setup; a user PC runs EMViewer.

EMProbe-DBM-E6 — 6-Axis Robotic Near-Field EMI Diagnostics on the Bench

6 axes | 450 mm radius | 0.01 mm positioning repeatability

EMProbe DBM E6 combines a six-axis robotic arm, near-field probes and EMViewer for repeatable component-side EMI investigations. The dedicated E6 datasheet specifies a 450 mm scan radius, scan spacing down to 0.1 mm and 0.01 mm positioning repeatability. Select the probe and compatible external analyzer to match the emissions and geometry being investigated.

EMProbe CR5 - Custom Large-Reach Robotic EMI Scanning System

Custom configuration | 6-axis robot | 900 mm working-radius example

EMProbe CR5 is a custom near-field scanning solution for larger DUTs and applications that need more reach than a compact bench arm. It combines a six-axis collaborative robot, application-specific probe mounting and EMViewer scan control with a compatible external spectrum analyzer. Each system is configured around the DUT geometry, probe selection, workspace and measurement objectives. Request a quotation for your application.

Langer ICS 105 | Compact IC workbench scanner

50 x 50 x 50 mm; +/-180 deg | 10 um linear; 1 deg rotation | USB | 110/230 V | 23 kg; 350 x 400 x 420 mm

ICS 105 provides X/Y/Z travel and motorized probe rotation for automated near-field measurements above ICs and small assemblies. Its compact footprint and 10 um minimum linear step suit focused IC investigations. Add the appropriate ICR microprobe or passive scanner probe for the field and spatial scale being measured.

Langer FLS 106 IC | Large-area scanner with probe rotation

400 x 600 x 120 mm; +/-180 deg | 20 um linear; 1 deg rotation | USB | 110/230 V | 75 kg; 1030 x 775 x 900 mm

FLS 106 IC combines a 400 x 600 x 120 mm work area with motorized alpha rotation. It suits larger assemblies and fixtures while retaining angular positioning for IC near-field work. The platform can be configured for surface scans and localized ESD/EFT investigations with the required probes, field sources and generators.

Langer FLS 106 PCB | Large-area three-axis PCB scanner

400 x 600 x 120 mm; no alpha axis | 20 um linear | USB | 110/230 V | 75 kg; 1030 x 775 x 900 mm

FLS 106 PCB provides automated X/Y/Z positioning over a 400 x 600 x 120 mm area for repeatable PCB near-field maps. A digital microscope camera supports optical positioning. The published collision-protection function stops downward probe movement when contact is detected; it does not replace careful setup or all protective measures.

Langer Scanner and Scanner Probe Comparison Guide

3 scanner platforms | Full and Basic packages | 12 passive scanner probes

Compare travel, axes, minimum step, speed, footprint, field type, probe geometry and frequency range before configuring an EMC scanning system.

Langer LFS Scanner Probes | 100 kHz to 50 MHz

100 kHz to 50 MHz | 1 probe models | Passive | SMA connection

LFS-B 3 is a passive H-field scanner probe for low-frequency magnetic-field investigations. Its orthogonal coil and perpendicular approach help reach PCB structures between taller components.


Loading...