CDG 7000-75-10 Magnetic & Conducted Immunity, 10 kHz - 250MHz

CDG 7000-75-10 Magnetic & Conducted Immunity, 10 kHz - 250MHz

MGA 1033; Magnetic Immunity DC-250 kHz, 800 Watts

MGA 1033; Magnetic Immunity DC-250 kHz, 800 Watts

PFS-CE-16: Dips/Drops/Variations

PFS-CE-16: Dips/Drops/Variations

VPS 250, Automatic Variack 0-250V 16Amps

VPS 250, Automatic Variack 0-250V 16Amps

HI 200, 1m x 1m Magnetic Immunity Coil for use with HILO/TEST

HI 200, 1m x 1m Magnetic Immunity Coil for use with HILO/TEST

Products

CDG 7000-75-10 Magnetic & Conducted Immunity, 10 kHz - 250MHz

The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields - including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. IEC 60601-1-2 calling out IEC 61000-4-39 magnetic immunity for close proximity testing requirements can also now be met with the 10 kHz unit. 

MGA 1033; Magnetic Immunity DC-250 kHz, 800 Watts

The compact magnetic field generator and analyzer MGA 1030 allows susceptibility tests against magnetic fields from DC to 250 kHz according to the standard EN 55103-2 and their measurement according to EN 55103-1. In addition, EMC tests are possible according to various standards such as automotive, avionic and MIL-STD.; Generation of magnetic fields from DC to 250 kHz; Field strength up to 1000 A/m; EN 55103-1/2, MIL-STD 461, Automotive etc.; Accessories: Loop sensors, Helmholtz coils etc.;

PFS-CE-16: Dips/Drops/Variations

The Power Fail Simulator PFS-CE-16 is a compact EMC test unit designed for testing electromagnetic immunity against interruption and variation of the power supply voltage acc. to IEC 61000-4-11. Demonstrating such immunity is generally a requirement of the European EMC directive, a necessary step leading to the final attachment of the CE mark.

VPS 250, Automatic Variack 0-250V 16Amps

Motor-driven variable transformer, controlled by Multi-CE5 or Multi-CE7, used for power supply variation acc. to IEC 61000-4-11 and setting current for IEC 61000-4-8 Magnetic fields

HI 200, 1m x 1m Magnetic Immunity Coil for use with HILO/TEST

Power frequency magnetic fields acc. to IEC 61000-4-8 Test levels continuous 3 / 10 / 30 / 100 / 300 A/m. Test level 1000 A/m short, with a special transformer. Pulsed magnetic fields acc. to IEC 61000-4-9 Test levels 100 / 300 / 1000 A/m


Loading...