Axos 5 - Compact 5kV EFT, Surge, Dips/Drops

Axos 5 - Compact 5kV EFT, Surge, Dips/Drops

Axos 8 - Compact 7kV Surge, Telecom, Ring Wave, 5kV EFT, Dips/Drops

Axos 8 - Compact 7kV Surge, Telecom, Ring Wave, 5kV EFT, Dips/Drops

PSURGE 30.2 Modular 30 kV / 30 kA Surge Test System

PSURGE 30.2 Modular 30 kV / 30 kA Surge Test System

FP-COMB 63 / 125 / 200 A - 690 V AC Coupling / Decoupling Networks

FP-COMB 63 / 125 / 200 A - 690 V AC Coupling / Decoupling Networks

FP-COMB 32, Combined Automatic 3-Phase Coupling / Decoupling Network

FP-COMB 32, Combined Automatic 3-Phase Coupling / Decoupling Network

CDN 5416 / 7416 / 10416 / 12416, 3-Phase, 16 Amp, Surge and EFT/burst, Coupling Decoupling Network

CDN 5416 / 7416 / 10416 / 12416, 3-Phase, 16 Amp, Surge and EFT/burst, Coupling Decoupling Network

CDN 10216 & 12216, 2-line, 16 Amp, Surge and EFT/burst, Coupling Decoupling Network

CDN 10216 & 12216, 2-line, 16 Amp, Surge and EFT/burst, Coupling Decoupling Network

CDN 5432 / 7432 / 10432 / 12432, 3-Phase, 32 Amp, Surge and EFT/burst, Coupling Decoupling Network

CDN 5432 / 7432 / 10432 / 12432, 3-Phase, 32 Amp, Surge and EFT/burst, Coupling Decoupling Network

CDN 5463 / 7463 / 10463 / 12463, 3-Phase, 63 Amp, Surge and EFT/burst, Coupling Decoupling Network

CDN 5463 / 7463 / 10463 / 12463, 3-Phase, 63 Amp, Surge and EFT/burst, Coupling Decoupling Network

CDN 54125 / 74125 / 104125 / 124125, 3-Phase, 125 Amp, Surge and EFT/burst, Coupling Decoupling Netw

CDN 54125 / 74125 / 104125 / 124125, 3-Phase, 125 Amp, Surge and EFT/burst, Coupling Decoupling Netw

CDN 54200 / 74200 / 104200 / 124200, 3-Phase, 200 Amp, Surge and EFT/burst, Coupling Decoupling Net.

CDN 54200 / 74200 / 104200 / 124200, 3-Phase, 200 Amp, Surge and EFT/burst, Coupling Decoupling Net.

CDN 504-sym / CDN 508-sym, Signal 4/8-Line,  Surge and EFT/burst, Coupling Decoupling Network

CDN 504-sym / CDN 508-sym, Signal 4/8-Line, Surge and EFT/burst, Coupling Decoupling Network

Products

Axos 5 - Compact 5kV EFT, Surge, Dips/Drops

Axos 5 - Compact

  • Multi Tester with 16AMP CDN
  • EFT/Burst 5kV IEC 61000-4-4
  • Surge, Combination Wave 5kV IEC 61000-4-5
  • Surge Magnetic field IEC 61000-4-9 (MSURGE-A loop antenna required)
  • AC Dips/Drops IEC 61000-4-11 (DIP 116 dips transformer required)
  • DC Dips/Drops IEC 61000-4-29 (2x DC supplies required)

Axos 8 - Compact 7kV Surge, Telecom, Ring Wave, 5kV EFT, Dips/Drops

Axos 8 - Compact

  • Multi Tester with 16AMP CDN
  • EFT/Burst 5kV IEC 61000-4-4
  • Surge, Combination Wave 7kV IEC 61000-4-5
  • Surge Magnetic field IEC 61000-4-9 (MSURGE-A loop antenna required)
  • Ring Wave, 7kV IEC 61000-4-12 & ANSI
  • Telicomm Wave, 7kV IEC 61000-4-5 & ITU
  • AC Dips/Drops IEC 61000-4-11 (DIP 116 dips transformer required)
  • DC Dips/Drops IEC 61000-4-29 (2x DC supplies required)

PSURGE 30.2 Modular 30 kV / 30 kA Surge Test System

PSURGE 30.2 

  • Surge System
  • Up to 30 kV impulse voltage
  • Up to 30 kA impulse current

FP-COMB 63 / 125 / 200 A - 690 V AC Coupling / Decoupling Networks

Automated transient testing for single- and three-phase AC power lines.

The Haefely FP-COMB /690-1 family combines surge, ring-wave and EFT/burst coupling and decoupling in one AXOS-controlled network. Choose 63, 125 or 200 A for AC-powered equipment up to 690 V. Limited DC operation is also specified: 110 V DC for the 63 A model and 200 V DC for the 125 A and 200 A models.

63 / 125 / 200 A | 7 kV surge and ring wave | 5 kV EFT/burst

FP-COMB 32, Combined Automatic 3-Phase Coupling / Decoupling Network

FP-COMB 32

  • Voltage 480V AC & DC
  • Current 32 AMPs
  • Automatic Switching Surge, EFT, Ringwave
  • IEC & ANSI Coupling

CDN 5416 / 7416 / 10416 / 12416, 3-Phase, 16 Amp, Surge and EFT/burst, Coupling Decoupling Network

The capacitive Coupling-/Decoupling Networks CDN 5416/7416/10416/12416 are used in combination with the Multi-CE5 or the Surge generators PG 7-250, PG 10-504, PG 12-804 and allow superimposition of surge and burst test pulses to the 3-phase mains voltage of the device under test.

CDN 10216 & 12216, 2-line, 16 Amp, Surge and EFT/burst, Coupling Decoupling Network

The capacitive Coupling-/Decoupling Network CDN 10216 & 12216 is used in combination with the Surge generators PG 7-250, PG 10-504 or PG 12-804 and allows superimposition of surge test pulses to the single-phase power supply voltage of the device under test. The test set-up is suitable for immunity testing of electronic systems and devices according to IEC 61000-4-4, IEC 61000-4-5 and IEEE 587.

CDN 5432 / 7432 / 10432 / 12432, 3-Phase, 32 Amp, Surge and EFT/burst, Coupling Decoupling Network

The capacitive Coupling-/Decoupling Networks CDN 5432/7432/10432/12432 are used in combination with the Multi-CE5 / Multi-CE7 or the Surge generators PG 7-250, PG 10-504, PG 12-804 and allow superimposition of surge and burst test pulses to the 3-phase mains voltage of the device under test.

CDN 5463 / 7463 / 10463 / 12463, 3-Phase, 63 Amp, Surge and EFT/burst, Coupling Decoupling Network

The capacitive Coupling-/Decoupling Networks CDN 5463/7463/10463/12463 are used in combination with the Multi-CE5 / Multi-CE7 or the Surge generators PG 7-250, PG 10-504, PG 12-804 and allow superimposition of surge and burst test pulses to the 3-phase mains voltage of the device under test.

CDN 54125 / 74125 / 104125 / 124125, 3-Phase, 125 Amp, Surge and EFT/burst, Coupling Decoupling Netw

The capacitive Coupling-/Decoupling Networks CDN 54125 / 74125 / 104125 / 124125 are used in combination with the Multi-CE5 / Multi-CE7 or the Surge generators PG 7-250, PG 10-504, PG 12-804 and allow superimposition of surge and burst test pulses to the 3-phase mains voltage of the device under test.

CDN 54200 / 74200 / 104200 / 124200, 3-Phase, 200 Amp, Surge and EFT/burst, Coupling Decoupling Net.

The capacitive Coupling-/Decoupling Networks CDN 54200/ 74200/ 104200/ 12420 are used in combination with the Multi-CE5 / Multi-CE7 or the Surge generators PG 7-250, PG 10-504, PG 12-804 and allow superimposition of surge and burst test pulses to the 3-phase mains voltage of the device under test.

CDN 504-sym / CDN 508-sym, Signal 4/8-Line, Surge and EFT/burst, Coupling Decoupling Network

Designed for applying the impulse output voltage of the Combination Wave Generator to interconnection lines of the equipment under test, acc. to IEC 61000-4-5, Fig10.


Loading...