Axos 5 - Compact
Axos 8 - Compact
PEFT 8010
The Haefely FP-COMB /690-1 family combines surge, ring-wave and EFT/burst coupling and decoupling in one AXOS-controlled network. Choose 63, 125 or 200 A for AC-powered equipment up to 690 V. Limited DC operation is also specified: 110 V DC for the 63 A model and 200 V DC for the 125 A and 200 A models.
63 / 125 / 200 A | 7 kV surge and ring wave | 5 kV EFT/burst
FP-COMB 32
Approx. 0-1500 V pulses | 2 ns rise / 10 ns tail | 4 H-field + 5 E-field sources | 10 Mbps optical sensor
E1 combines the SGZ 21 burst generator with magnetic and electric field sources for finding PCB weaknesses associated with EFT/burst and ESD. Apply a localized disturbance, observe the failure, then compare the result after a grounding, shielding or circuit change. The compact bench system includes an S21 optical sensor, an MS 02 magnetic probe, accessories, power supply, case and manual.
Up to 2.2 kV adjustable | 1.5 ns rise | Adjustable 1.5 kHz repetition | Both polarities | 50 Mbps optical sensor
The E2 Set uses the TS 23 pulse generator to investigate PCB and device susceptibility during development or after an immunity test failure. Magnetic, electric and resistive coupling tools help separate the entry path from the sensitive circuit. Adjustable amplitude, polarity and pulse modes let engineers reproduce a failure and evaluate a design change at the workbench. The kit includes a ground plate, differential injectors, S25 optical sensor and coupling accessories.
The ESD Test Table Kit is a simple inexpensive solution for your ESD testing. Complies to the requirements of IEC 61000-4-2 and can be used for additional standards. Comes with a Horizontal Coupling Plane (HCP), resistive cable to tie HCP to floor ground plane, bleeder wire for discharging ungrounded battery powered EUTs, 0.05mm insulator and an alternative low impedance ground for using the table for additional setups such as IEC 61000-4-6 requirements.
The capacitive Coupling-/Decoupling Networks CDN 5416/7416/10416/12416 are used in combination with the Multi-CE5 or the Surge generators PG 7-250, PG 10-504, PG 12-804 and allow superimposition of surge and burst test pulses to the 3-phase mains voltage of the device under test.
The capacitive Coupling-/Decoupling Network CDN 10216 & 12216 is used in combination with the Surge generators PG 7-250, PG 10-504 or PG 12-804 and allows superimposition of surge test pulses to the single-phase power supply voltage of the device under test. The test set-up is suitable for immunity testing of electronic systems and devices according to IEC 61000-4-4, IEC 61000-4-5 and IEEE 587.
The capacitive Coupling-/Decoupling Networks CDN 5432/7432/10432/12432 are used in combination with the Multi-CE5 / Multi-CE7 or the Surge generators PG 7-250, PG 10-504, PG 12-804 and allow superimposition of surge and burst test pulses to the 3-phase mains voltage of the device under test.
The capacitive Coupling-/Decoupling Networks CDN 5463/7463/10463/12463 are used in combination with the Multi-CE5 / Multi-CE7 or the Surge generators PG 7-250, PG 10-504, PG 12-804 and allow superimposition of surge and burst test pulses to the 3-phase mains voltage of the device under test.