50 x 50 x 50 mm; +/-180 deg | 10 um linear; 1 deg rotation | USB | 110/230 V | 23 kg; 350 x 400 x 420 mm
ICS 105 provides X/Y/Z travel and motorized probe rotation for automated near-field measurements above ICs and small assemblies. Its compact footprint and 10 um minimum linear step suit focused IC investigations. Add the appropriate ICR microprobe or passive scanner probe for the field and spatial scale being measured.
MARKETS:
CATEGORIES:
TEST STANDARDS:
Select Options/Sizes:
ICS 105 provides X/Y/Z travel and motorized probe rotation for automated near-field measurements above ICs and small assemblies. Its compact footprint and 10 um minimum linear step suit focused IC investigations. Add the appropriate ICR microprobe or passive scanner probe for the field and spatial scale being measured.
| Benefit | Engineering value |
|---|---|
| Application fit | Choose for a small IC scan area, finer minimum positioning increment and a compact bench footprint. |
| Reproducible positioning | Automate repeatable probe paths and document field patterns across a plane or volume. Positioning precision and field resolution remain separate specifications. |
| Probe choice | Use an E-field or H-field geometry appropriate to the suspected noise path. Microprobes resolve a smaller region than general PCB survey probes. |
| Two software packages | Full sets include ChipScan-Scanner. Basic sets omit it and target users integrating their own automation. Confirm SDK/API delivery and license requirements. |
| Parameter | Published specification |
|---|---|
| Supply voltage | 110 / 230 V |
| Interface | USB |
| Max. traverse range | (50 x 50 x 50) mm; alpha-Rotation +/-180 deg |
| Min. step size | (10 x 10 x 10) um; alpha-Rotation 1 deg |
| Positioning speed | (10 x 10 x 5) mm/s; alpha-Rotation 90 deg/s |
| Weight | 23 kg |
| Sizes (L x W x H) | (350 x 400 x 420) mm |
Axes: X, Y, Z and alpha rotation.
A Basic set omits ChipScan-Scanner software, but its published accessory list must also be checked. In particular, ICS 105 Basic lists GND mount instead of GND 25; the FLS 106 IC Basic list omits GND 25. Unlisted items are not assumed included. Probes and RF measurement instruments are selected separately.
ChipScan-Scanner supports planar and volumetric field acquisition, visualization, processing and analysis, and image/data export. The full set includes the USB software license. Basic sets do not include ChipScan-Scanner. The separate Langer SDK supports custom positioning-control software on Windows and Linux; this does not mean the ChipScan-Scanner desktop application runs on Linux.
| Computer requirement | Published value |
|---|---|
| Operating system | Windows 11/10 64-bit (latest service packs) |
| Monitor resolution | (1280 x 1024) px |
| HD space | 1 GB |
| Processor | Intel Core i7 2.7 GHz |
| Memory | 8 GB |
| Graphics card | AMD Radeon 7950 |
| Graphics memory | 3 GB |
Download spectrum analyzer compatibility and interface guide (PDF). Model, interface, driver-test status, listed firmware and limitations are kept in this separate document. Confirm the software version, firmware and connection before ordering.
| View | Description |
|---|---|
![]() |
3D scan |
![]() |
Surface scan |
LFS, RFS and XFS passive scanner probes are available as configuration choices; verify the required holder, clearance and orientation. ICR microprobes and injection probes belong to separate product families and need their corresponding setup.
| Family | Models | Coverage | Field types | Choose for |
|---|---|---|---|---|
LFS |
1 | 100 kHz-50 MHz | H | Low-frequency switching-current and magnetic-field mapping. |
RFS |
7 | 30 MHz-3 GHz | H and E | General PCB investigations with large-area and fine-resolution geometries. |
XFS |
4 | 30 MHz-6 GHz | H and E | PCB near-field mapping when coverage above 3 GHz is needed. |
The passive scanner probes below have model-specific SMA connections and no power supply in their published specification. ICR near-field microprobes are a separate precision-probe class; use the existing ICR near-field microprobe range when micrometer-scale sensing is needed.
| Product | Document |
|---|---|
| ICS 105 set | ICS 105 set - Datasheet |
| ICS 105 basic set | ICS 105 basic set - Datasheet |
| CS-Scanner | CS-Scanner - Datasheet |
| SH 01 | SH 01 - Datasheet |
| UH DUT | UH DUT - Datasheet |
| GND 25 | GND 25 - Datasheet |
Open the complete scanner and scanner-probe comparison guide
| Scanner | Best fit / benefit | Travel and axes | Minimum step | Positioning speed | Weight / footprint |
|---|---|---|---|---|---|
ICS 105 |
Compact IC workbench scanner Choose for a small IC scan area, finer minimum positioning increment and a compact bench footprint. |
50 x 50 x 50 mm; +/-180 deg | 10 um linear; 1 deg rotation | 10 / 10 / 5 mm/s; 90 deg/s | 23 kg; 350 x 400 x 420 mm |
FLS 106 IC |
Large-area scanner with probe rotation Choose when the DUT or fixture needs a larger area and IC-style angular probe scans are important. |
400 x 600 x 120 mm; +/-180 deg | 20 um linear; 1 deg rotation | 20 / 25 / 10 mm/s; 90 deg/s | 75 kg; 1030 x 775 x 900 mm |
FLS 106 PCB |
Large-area three-axis PCB scanner Choose for repeatable X/Y/Z scans over assemblies without the IC model's motorized alpha rotation. |
400 x 600 x 120 mm; no alpha axis | 20 um linear | 20 / 25 / 10 mm/s | 75 kg; 1030 x 775 x 900 mm |
Travel, step size and speed are listed in X/Y/Z order. Minimum positioning step is not probe spatial resolution, repeatability or positioning accuracy. Achievable field-map detail depends on probe size, spacing, orientation and the complete measurement chain. Scanner frequency coverage is determined by the selected probe and RF instrument, not the motion platform.