CDG 7000 Conducted Immunity, 10 kHz - 400MHz

CDG 7000 Conducted Immunity, 10 kHz - 400MHz

CDG 7000-E Conducted Immunity Generator, (4)9 kHz - 1 GHz , No internal Amplifier

CDG 7000-E Conducted Immunity Generator, (4)9 kHz - 1 GHz , No internal Amplifier

CDG 7000-75-10 Magnetic & Conducted Immunity, 10 kHz - 250MHz

CDG 7000-75-10 Magnetic & Conducted Immunity, 10 kHz - 250MHz

MAG 1000, 120A/m CW, 1100Am Short Duration, Power Frequency Magnetic Field

MAG 1000, 120A/m CW, 1100Am Short Duration, Power Frequency Magnetic Field

EMCL- NW 10 / MN-1 EM Clamp Matching Network

EMCL- NW 10 / MN-1 EM Clamp Matching Network

CDN ABCL-20 Decoupling Clamp

CDN ABCL-20 Decoupling Clamp

CDN BCI-P1 Bulk Current Injection Probe 1 MHz – 400 MHz

CDN BCI-P1 Bulk Current Injection Probe 1 MHz – 400 MHz

CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz

CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz

CDG CMP-45 Current Monitoring Probe, Foldable, with Calibration Set

CDG CMP-45 Current Monitoring Probe, Foldable, with Calibration Set

CDG CMP-46 Current Monitoring Probe, with Calibration Set

CDG CMP-46 Current Monitoring Probe, with Calibration Set

Products

CDG 7000 Conducted Immunity, 10 kHz - 400MHz

The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields - including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price.

CDG 7000-E Conducted Immunity Generator, (4)9 kHz - 1 GHz , No internal Amplifier

The CDG 7000-E is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields - including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. Use an external Amplifier you already have or one that matches your application. 

  • The compact device comprises an RF signal generator, a 3-channel RF voltmeter, and a directional coupler.
  • Frequency range of the generator/power meter (4 kHz): 9 kHz – 1200 MHz
  • The frequency range of the directional coupler: 10 kHz – 1000 MHz, 200 W 
  • Depending on ext. amplifier:  IEC/EN 61000-4-6, IEC 60601-1-2 Ed. 4.1,  IEC 61000-4-39, MIL 461 CS 114, ISO 11452-4, ...

CDG 7000-75-10 Magnetic & Conducted Immunity, 10 kHz - 250MHz

The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields - including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. IEC 60601-1-2 calling out IEC 61000-4-39 magnetic immunity for close proximity testing requirements can also now be met with the 10 kHz unit. 

MAG 1000, 120A/m CW, 1100Am Short Duration, Power Frequency Magnetic Field

MAG 1000

  • 1-120A/m Contiunus testing
  • 100-1100A/m Short Duration 1-3sec
  • Test either 50Hz & 60Hz Selectable
  • 1m square Loop

EMCL- NW 10 / MN-1 EM Clamp Matching Network

EMCL- NW 10 / MN-1 Matching Network • For use with the EMCL-20 in the frequency range 10 kHz – 150 kHz • For use with the CDN BCI-P1 in the frequency range 10 kHz – 150 kHz

CDN ABCL-20 Decoupling Clamp

CDN ABCL-20 Decoupling Clamp for immunity according to IEC / EN 61000-4-6 Ed. 4.0 100 kHz – 1000 MHz Features: For additional decoupling at immunity testing according to IEC / EN 61000-4-6 Suitable for cables up to 20mm diameter

CDN BCI-P1 Bulk Current Injection Probe 1 MHz – 400 MHz

BCI-P1 Bulk Current Injection Probe 10 kHz – 400 MHz - Meets specifications of ISO 11452-4:2005 and IEC 61000-4-6 - Frequency range from 1 MHz up to 400 MHz - Designed for automotive BCI testing - Low insertion loss (1MHz - 400MHz) to test bellow 1MHz (IEC/DO/MIL) see CDN BCI-P1_MT-1

CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz

CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz - Meets specifications of ISO 11452-4:2005, MIL-STD-461, DO-160 and IEC 61000-4-6 - Frequency range from 4 kHz up to 400 MHz - Designed for BCI testing 

CDG CMP-45 Current Monitoring Probe, Foldable, with Calibration Set

CDG CMP-45 Current monitoring probe • Cable diameters up to 45 mm • Frequency range 10 kHz to 400 MHz • Foldable, easy positioning on the conductor / cable • For BCI testing acc. to ISO 11452-4 and others • Insertion impedance < 2,5 ?

CDG CMP-46 Current Monitoring Probe, with Calibration Set

CDG CMP-46 Current monitoring probe • Cable diameters up to 45 mm • Frequency range 10 kHz to 400 MHz • For BCI testing acc. to ISO 11452-4 and others • Insertion impedance < 2,5 ?