CDG 7000 Conducted Immunity, 10 kHz - 400MHz

CDG 7000 Conducted Immunity, 10 kHz - 400MHz

CDG 7000-E Conducted Immunity Generator, (4)9 kHz - 1 GHz , No internal Amplifier

CDG 7000-E Conducted Immunity Generator, (4)9 kHz - 1 GHz , No internal Amplifier

CDG 7000-75-10 Magnetic & Conducted Immunity, 10 kHz - 250MHz

CDG 7000-75-10 Magnetic & Conducted Immunity, 10 kHz - 250MHz

Wood Test Table Kit

Wood Test Table Kit

CDN M-type - Mains / Power supply applications

CDN M-type - Mains / Power supply applications

CDN S-type - Screened cables

CDN S-type - Screened cables

CDN AF-type - Unscreened unbalanced lines

CDN AF-type - Unscreened unbalanced lines

CDN T-type - Unscreened balanced lines

CDN T-type - Unscreened balanced lines

CDN ABCL-20 Decoupling Clamp

CDN ABCL-20 Decoupling Clamp

EMCL- NW 10 / MN-1 EM Clamp Matching Network

EMCL- NW 10 / MN-1 EM Clamp Matching Network

CDN BCI-P1 Bulk Current Injection Probe 1 MHz – 400 MHz

CDN BCI-P1 Bulk Current Injection Probe 1 MHz – 400 MHz

CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz

CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz

Products

CDG 7000 Conducted Immunity, 10 kHz - 400MHz

The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields - including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price.

CDG 7000-E Conducted Immunity Generator, (4)9 kHz - 1 GHz , No internal Amplifier

The CDG 7000-E is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields - including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. Use an external Amplifier you already have or one that matches your application. 

  • The compact device comprises an RF signal generator, a 3-channel RF voltmeter, and a directional coupler.
  • Frequency range of the generator/power meter (4 kHz): 9 kHz – 1200 MHz
  • The frequency range of the directional coupler: 10 kHz – 1000 MHz, 200 W 
  • Depending on ext. amplifier:  IEC/EN 61000-4-6, IEC 60601-1-2 Ed. 4.1,  IEC 61000-4-39, MIL 461 CS 114, ISO 11452-4, ...

CDG 7000-75-10 Magnetic & Conducted Immunity, 10 kHz - 250MHz

The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields - including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. IEC 60601-1-2 calling out IEC 61000-4-39 magnetic immunity for close proximity testing requirements can also now be met with the 10 kHz unit. 

Wood Test Table Kit

The Wood Test Table is a simple, inexpensive solution for your EMC testing. The table is built to be ship flattened to reduce shipping costs and easily assembled on site quickly. The picture is shown with a ground plane.

CDN M-type - Mains / Power supply applications

The Coupling- / Decoupling Networks are used to inject common-mode disturbances to Equipment under Test (EuT). Further, the CDNs provide sufficient decoupling between Auxiliary Equipment (AE) and disturbance signal. The requirements for CDN and their application are described in the standard IEC 61000-4-6 (Immunity to conducted disturbances, induced by radio-frequency fields). CDNs have a common mode impedance of 150 Ohm and are available for a multitude of cable types and connectors.

CDN S-type - Screened cables

The Coupling- / Decoupling Networks are used to inject common-mode disturbances to Equipment under Test (EuT). Further, the CDNs provide sufficient decoupling between Auxiliary Equipment (AE) and disturbance signal. The requirements for CDN and their application are described in the standard IEC 61000-4-6 (Immunity to conducted disturbances, induced by radio-frequency fields). CDNs have a common mode impedance of 150 Ohm and are available for a multitude of cable types and connectors.

CDN AF-type - Unscreened unbalanced lines

The Coupling- / Decoupling Networks are used to inject common-mode disturbances to Equipment under Test (EuT). Further, the CDNs provide sufficient decoupling between Auxiliary Equipment (AE) and disturbance signal. The requirements for CDN and their application are described in the standard IEC 61000-4-6 (Immunity to conducted disturbances, induced by radio-frequency fields). CDNs have a common mode impedance of 150 Ohm and are available for a multitude of cable types and connectors.

CDN T-type - Unscreened balanced lines

The Coupling / Decoupling Networks are used to inject common-mode disturbances to Equipment under Test (EuT). Further, the CDNs provide sufficient decoupling between Auxiliary Equipment (AE) and disturbance signal. The requirements for CDN and their application are described in the standard IEC 61000-4-6 (Immunity to conducted disturbances, induced by radio-frequency fields). CDNs have a common mode impedance of 150 Ohm and are available for a multitude of cable types and connectors.

CDN ABCL-20 Decoupling Clamp

CDN ABCL-20 Decoupling Clamp for immunity according to IEC / EN 61000-4-6 Ed. 4.0 100 kHz – 1000 MHz Features: For additional decoupling at immunity testing according to IEC / EN 61000-4-6 Suitable for cables up to 20mm diameter

EMCL- NW 10 / MN-1 EM Clamp Matching Network

EMCL- NW 10 / MN-1 Matching Network • For use with the EMCL-20 in the frequency range 10 kHz – 150 kHz • For use with the CDN BCI-P1 in the frequency range 10 kHz – 150 kHz

CDN BCI-P1 Bulk Current Injection Probe 1 MHz – 400 MHz

BCI-P1 Bulk Current Injection Probe 10 kHz – 400 MHz - Meets specifications of ISO 11452-4:2005 and IEC 61000-4-6 - Frequency range from 1 MHz up to 400 MHz - Designed for automotive BCI testing - Low insertion loss (1MHz - 400MHz) to test bellow 1MHz (IEC/DO/MIL) see CDN BCI-P1_MT-1

CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz

CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz - Meets specifications of ISO 11452-4:2005, MIL-STD-461, DO-160 and IEC 61000-4-6 - Frequency range from 4 kHz up to 400 MHz - Designed for BCI testing 


Loading...