Axos 5 - Compact 5kV EFT, Surge, Dips/Drops

Axos 5 - Compact 5kV EFT, Surge, Dips/Drops

Axos 8 - Compact 7kV Surge, Telecom, Ring Wave, 5kV EFT, Dips/Drops

Axos 8 - Compact 7kV Surge, Telecom, Ring Wave, 5kV EFT, Dips/Drops

PEFT 8010 EFT/Burst Test System up to 7.3 kV

PEFT 8010 EFT/Burst Test System up to 7.3 kV

PSURGE 30.2 Modular 30 kV / 30 kA Surge Test System

PSURGE 30.2 Modular 30 kV / 30 kA Surge Test System

FP-COMB 63/690-1, Combined Automatic 3-Phase Coupling / Decoupling Network

FP-COMB 63/690-1, Combined Automatic 3-Phase Coupling / Decoupling Network

FP-COMB 32, Combined Automatic 3-Phase Coupling / Decoupling Network

FP-COMB 32, Combined Automatic 3-Phase Coupling / Decoupling Network

ESD Test Table Kit

ESD Test Table Kit

EFT 2012 EFT/Burst Capacitive Coupling Clamp

EFT 2012 EFT/Burst Capacitive Coupling Clamp

CDN 5416 / 7416 / 10416 / 12416, 3-Phase, 16 Amp, Surge and EFT/burst, Coupling Decoupling Network

CDN 5416 / 7416 / 10416 / 12416, 3-Phase, 16 Amp, Surge and EFT/burst, Coupling Decoupling Network

CDN 5432 / 7432 / 10432 / 12432, 3-Phase, 32 Amp, Surge and EFT/burst, Coupling Decoupling Network

CDN 5432 / 7432 / 10432 / 12432, 3-Phase, 32 Amp, Surge and EFT/burst, Coupling Decoupling Network

CDN 5463 / 7463 / 10463 / 12463, 3-Phase, 63 Amp, Surge and EFT/burst, Coupling Decoupling Network

CDN 5463 / 7463 / 10463 / 12463, 3-Phase, 63 Amp, Surge and EFT/burst, Coupling Decoupling Network

CDN 54125 / 74125 / 104125 / 124125, 3-Phase, 125 Amp, Surge and EFT/burst, Coupling Decoupling Netw

CDN 54125 / 74125 / 104125 / 124125, 3-Phase, 125 Amp, Surge and EFT/burst, Coupling Decoupling Netw

Products

Axos 5 - Compact 5kV EFT, Surge, Dips/Drops

Axos 5 - Compact

  • Multi Tester with 16AMP CDN
  • EFT/Burst 5kV IEC 61000-4-4
  • Surge, Combination Wave 5kV IEC 61000-4-5
  • Surge Magnetic field IEC 61000-4-9 (MSURGE-A loop antenna required)
  • AC Dips/Drops IEC 61000-4-11 (DIP 116 dips transformer required)
  • DC Dips/Drops IEC 61000-4-29 (2x DC supplies required)

Axos 8 - Compact 7kV Surge, Telecom, Ring Wave, 5kV EFT, Dips/Drops

Axos 8 - Compact

  • Multi Tester with 16AMP CDN
  • EFT/Burst 5kV IEC 61000-4-4
  • Surge, Combination Wave 7kV IEC 61000-4-5
  • Surge Magnetic field IEC 61000-4-9 (MSURGE-A loop antenna required)
  • Ring Wave, 7kV IEC 61000-4-12 & ANSI
  • Telicomm Wave, 7kV IEC 61000-4-5 & ITU
  • AC Dips/Drops IEC 61000-4-11 (DIP 116 dips transformer required)
  • DC Dips/Drops IEC 61000-4-29 (2x DC supplies required)

PEFT 8010 EFT/Burst Test System up to 7.3 kV

PEFT 8010 

  • EFT/Burst
  • Up to 7.3kV (6.6kV at CDN)
  • CDN: 264V-AC 16-440Hz, 125V-DC
  • CDN: 16A-AC @ 50-60Hz, 10A-AC @ 400Hz, 16A-DC

PSURGE 30.2 Modular 30 kV / 30 kA Surge Test System

PSURGE 30.2 

  • Surge System
  • Up to 30 kV impulse voltage
  • Up to 30 kA impulse current

FP-COMB 63/690-1, Combined Automatic 3-Phase Coupling / Decoupling Network

FP-COMB 63/690-1

  • Voltage 690V AC & DC
  • Current 63 AMPs
  • Automatic Switching Surge, EFT, Ringwave
  • IEC & ANSI Coupling

FP-COMB 32, Combined Automatic 3-Phase Coupling / Decoupling Network

FP-COMB 32

  • Voltage 480V AC & DC
  • Current 32 AMPs
  • Automatic Switching Surge, EFT, Ringwave
  • IEC & ANSI Coupling

ESD Test Table Kit

The ESD Test Table Kit is a simple inexpensive solution for your ESD testing. Complies to the requirements of IEC 61000-4-2 and can be used for additional standards. Comes with a Horizontal Coupling Plane (HCP), resistive cable to tie HCP to floor ground plane, bleeder wire for discharging ungrounded battery powered EUTs, 0.05mm insulator and an alternative low impedance ground for using the table for additional setups such as IEC 61000-4-6 requirements.

EFT 2012 EFT/Burst Capacitive Coupling Clamp

The Capacitive Coupling Clamp, EFTC 2012, provides the ability to couple Burst / EFT pulses to data lines. It can also be used for coupling to main lines where no CDN is available, for example, high current lines >200 A.

CDN 5416 / 7416 / 10416 / 12416, 3-Phase, 16 Amp, Surge and EFT/burst, Coupling Decoupling Network

The capacitive Coupling-/Decoupling Networks CDN 5416/7416/10416/12416 are used in combination with the Multi-CE5 or the Surge generators PG 7-250, PG 10-504, PG 12-804 and allow superimposition of surge and burst test pulses to the 3-phase mains voltage of the device under test.

CDN 5432 / 7432 / 10432 / 12432, 3-Phase, 32 Amp, Surge and EFT/burst, Coupling Decoupling Network

The capacitive Coupling-/Decoupling Networks CDN 5432/7432/10432/12432 are used in combination with the Multi-CE5 / Multi-CE7 or the Surge generators PG 7-250, PG 10-504, PG 12-804 and allow superimposition of surge and burst test pulses to the 3-phase mains voltage of the device under test.

CDN 5463 / 7463 / 10463 / 12463, 3-Phase, 63 Amp, Surge and EFT/burst, Coupling Decoupling Network

The capacitive Coupling-/Decoupling Networks CDN 5463/7463/10463/12463 are used in combination with the Multi-CE5 / Multi-CE7 or the Surge generators PG 7-250, PG 10-504, PG 12-804 and allow superimposition of surge and burst test pulses to the 3-phase mains voltage of the device under test.

CDN 54125 / 74125 / 104125 / 124125, 3-Phase, 125 Amp, Surge and EFT/burst, Coupling Decoupling Netw

The capacitive Coupling-/Decoupling Networks CDN 54125 / 74125 / 104125 / 124125 are used in combination with the Multi-CE5 / Multi-CE7 or the Surge generators PG 7-250, PG 10-504, PG 12-804 and allow superimposition of surge and burst test pulses to the 3-phase mains voltage of the device under test.