HV - Impulse generator PG 4-641 creates standard voltage and current pulses with a waveform 10 / 160 µs. The output voltage is adjustable up to 3600 V, the maximum short circuit current amplitude is 480 A peak. Positive or negative polarity of output voltage can be selected. A built-in voltage divider 1000:1 allows monitoring of the impulse output waveform during testing. The short circuit current wave can be monitored by the use of the built-in shunt.
PARTNER:
MARKETS:
CATEGORIES:
TEST STANDARDS:
High-Voltage Pulse Generator
| |
PG 4-641
| |
HV - Impulse generator PG 4-641 creates standard voltage and current pulses with waveform 10 / 160 µs. Output voltage is adjustable up to 3600 V, the maximum short circuit current amplitude is 480 A peak. Positive or negative polarity of output voltage can be selected. A built-in voltage divider 1000:1 allows monitoring of the impulse output waveform during testing. The short circuit current wave can be monitored by the use of the built-in shunt.
The generator features a microprocessor-controlled user interface and display for ease of use. The microprocessor allows the user to execute either standard test routines or a ´user-defined´ test sequence. The test parameters, which are shown on the built-in display, are easily adjusted by means of the rotary encoder.
The generator excels by its compact design, simple handling and precise reproducibility of test impulses.
| |
Technical specification: |
PG 4-641 |
Mainframe: |
|
| Microprocessor controlled LCD module | 8*40 characters |
| Parallel printer interface for on-line documentation | 25-way ´D´ connector |
| Optical-interface for remote control of the generator | built-in |
| External Trigger input | 10 V at 1 kW |
| External Trigger output | 10 V at 1 kW |
| Diagnostic input for monitoring of the test device | four channels, 5 V - Level |
| Connector for external safety interlock loop | 24 V = |
| and external red and green warning lamps acc. to VDE 0104 | 230 V, 60 W |
| Mains power | 230 V, 50/60 Hz |
| Dimensions: 19" desktop case W * H * D | 450*410*520 mm3 Weight |
| Generator section: | |
| Peak value of impulse output voltage, adjustable, | 0 - 3600 V, ± 10% |
| Waveform of impulse output voltage: Front time | 10 µs, + 0 / -5 µs |
| Duration | 160 µs, +160 / -0 µs |
| Peak value of impulse short circuit output current | 480 A, ± 10% |
| Waveform of short circuit current: Front time | 10 µs, + 0 / -5 µs |
| Duration | 160 µs, ± 32 µs |
| Max. stored energy | 600 W sec |
| Energy storage capacitor CS | 80 µF |
| Output polarity, selectable | pos./neg. |
| Charging time | 20 sec |
| Trigger: a) manual | push button |
| b) external Trigger input | 10 V / 1 kW |
| c) internal, automatic | test procedure |
| Impulse voltage divider, built-in | ratio 1000:1 ± 2% |
| Impulse current shunt, built-in | 5 mW ± 2% |
| |
|
|