The high-voltage impulse generator PG 20-4000 generates standard impulse voltages with waveform 10/700 µs. The output voltage is adjustable between 1 kV and 20 kV. The polarity of the output voltage is selectable, positive or negative.
PARTNER:
MARKETS:
TEST STANDARDS:
PG 20 - 4000
High voltage pulse generator
|
According to |
CCITT-K17/K20/K22 |
ITU-T/K44 |
VDE 0847 |
The high-voltage impulse generator PG 20-4000 generates standard impulse voltages with waveform 10/700 µs. The output voltage is adjustable between 1 kV and 20 kV. The polarity of the output voltage is selectable, positive or negative.
It is designed for dielectric testing of components and systems acc. to CCITT K17/K20/K22, ITU-T/K44, IEC 61000-4-5, EN 61000-4-5, VDE 0847. One high-voltage output with a series resistor of 25 W for direct testing of surge protection devices is available. The short circuit current with the waveform 5/310 µs can be adjusted up to 500 A by selection of charging voltage.
PG 20-4000 features a microprocessor-controlled user interface and a 5” touch screen unit for ease of use. The microprocessor allows the user to execute either standard test routines or a “user-defined” test sequence. A standard USB port provides the ability to print a summary of the test parameters to a USB stick.
The software program HILO-REMOTE allows full remote control of the test generator via Ethernet light guide as well as documentation and evaluation of test results, accordingly to the IEC 17025. To record definite impulses, it is equipped with an Impulse Recording Function (IRF) Moreover, all generator functions may be computer-controlled via the isolated optical interface.
TECHNICAL SPECIFICATIONS |
PG 20-4000 |
|
|
Mainframe: |
|
Microprocessor controlled touch panel |
7”, 800X480, 24 bit |
Optical Ethernet Interface for remote control of the generator |
optional |
Interface for saving reports |
USB |
External Trigger input |
switch |
External Trigger output |
10 V at 1 kW |
Connector for external safety interlock loop |
24 V = |
External red and green warning lamps |
230 V, 60W |
Mains power |
230 V, 50/60 Hz |
Dimensions of desktop case W * H * D |
555*604*800 mm3 |
Weight |
110 kg |
|
|
High-voltage pulse generator |
|
Impulse output voltage, adjustable |
1-20 kV ± 5% |
Polarity of pulse output, selectable |
pos/ neg / alt |
Max. energy stored |
4000 J |
Charging time, max. |
< 50 sec |
max. repetition rate |
1/60 sec |
|
|
Pulse forming network |
10/700µs |
|
|
Peak output voltage, adjustable by preset of charging voltage |
1 - 20 kV ±5% |
Waveform of open-loop output voltage: front time/tail time |
10 / 700 µs ± 30%/20% |
Peak output current, adjustable by preset of charging voltage |
25 - 500 A ±10% |
Waveform of short circuit output current: front time/tail time |
5/320 µs ± 20% |
|
|
Option : |
|
Software HILO-REMOTE, for remote control |
|
With Impulse Recording Function (IRF) |
|
( XP, WIN7, WIN8, WIN10 ) incl. 5m long light guide and PC Ethernet interface |
|
Option : |
|
Description of Remote control commands |
|
Incl. Ethernet PC-interface and 5m long light-guide |
|
Option : |
|
Different test cabinets |
|
Option: |
|
Impulse voltage divider integrated |
ratio = 1000:1 ± 5% |
Monitor output for pulse output current, built-in |
20 mW, 1.0 MHz |
|