PG 14 - 1960, High Voltage Pulse Generator, 10/700µs, 0.5/700µs, 14kV

The high-voltage impulse generator PG 14-1960 generates standard impulse voltages with waveforms 10/700 µs. The output waveform can be switched to 0.5/700µs wave. Output voltage is adjustable between 0.2 kV and 14 kV. The polarity of the output voltage is selectable. Positive, negative or alternating polarity of the output voltage can be preselected.

PARTNER:

TEST STANDARDS:

Data Sheet

SPECIFICATIONS

PG 14 - 1960

  

 

 

High voltage pulse generator

   

 

  • Switching surge:
  • 10 / 700 µs & 0.5 / 700 µs
  • 0.2 - 14 kV

 

 

 

According to

CCITT-K17/K20/K22

ITU-T/K44

VDE 0847

 

 

The high-voltage impulse generator PG 14-1960 generates standard impulse voltages with waveforms 10/700 µs. The output waveform can be switched to 0.5/700µs wave. The output voltage is adjustable between 0.2 kV and 14 kV. The polarity of the output voltage is selectable. Positive, negative or alternating polarity of the output voltage can be preselected.

 

It is designed for dielectric testing of components and systems acc. to CCITT-K17/K20/K22, ITU-T/K44, IEC 61000-4-5, EN 61000-4-5, VDE 0847. Two high-voltage outputs with a series resistor of 25 W for direct testing of A - B wires are available.

 

A built-in voltage divider 1000:1 allows monitoring of the impulse output waveform during testing.

 

PG 14-1960 features a microprocessor-controlled user interface and a 5” touch screen unit for ease of use. The microprocessor allows the user to execute either standard test routines or a “user-defined” test sequence. A standard USB port provides the ability to print a summary of the test parameters to a USB stick.

 

 

The software program HILO-REMOTE allows full remote control of the test generator via Ethernet light guide as well as documentation and evaluation of test results, accordingly to  the IEC 17025. To record definite impulses, it is equipped with an Impulse Recording  Function (IRF) Moreover all generator functions may be computer-controlled via the isolated optical interface.

 

 

 

TECHNICAL SPECIFICATIONS

PG 14-1960

 

 

Mainframe:

 

Microprocessor controlled touch panel

5”, 800X480, 24 bit

Optical Ethernet Interface for remote control of the generator

optional

Interface for saving reports

USB

External Trigger input

switch

External Trigger output

10 V at 1 kW

Connector for external safety interlock loop

24 V =

External red and green warning lamps

230 V, 60W

Mains power

230 V, 50/60 Hz

Dimensions of desk top case W * H * D

555*604*600 mm3

Weight

96 kg

 

 

High-voltage pulse generator

 

Impulse output voltage, adjustable

0.2-14.0 kV ± 5%

Polarity of output voltage/current, selectable

pos/neg/alt

Charging time

< 25 sec

 

 

Pulse forming networks:

selectable

 

 

a)Impulse voltage 10/700µs acc. To CCITT K17/K20

PFN 10/700

Energy storage capacitor

20 µF / 14.6 kV

Discharging resistor/ Series resistor

50 W/ 15 W

Load capacitor

0.2 µF

Wave form: front time/tail time

10 / 700 µs ±20%

 

 

b)Impulse voltage 0.5/700µs acc. to CNET

PFN 0.5/700

Load capacitance

0.007 µF

Wave form: front time/tail time

0.5 / 700 µs ± 30/20%

 

 

Direct pulse voltage output on the rear panel

coaxial

current limiting resistors

25 W / 25 W

for connection of external coupling devices Monitor output for pulse output voltage

ratio = 1000 : 1 ± 5%

 

 

Option :

 

Software HILO-REMOTE, for remote control

 

With Impulse Recording Function (IRF)

 

( XP, WIN7, WIN8, WIN10 ) incl. 5m long light guide and PC Ethernet interface

 

Option :

 

Description of Remote control commands

 

Incl. Ethernet PC-interface and 5m long light-guide

 

Option :

 

Different test cabinets

 

 

 

 

 