The HV - Impulse generators IPG 2025 and IPG 2436 create standard impulse voltages with waveform 1.2 / 50 µs acc. to IEC 60060. They are designed for testing impulse dielectric strength of components, insulations, air- and surface flash-over gaps according to the standards. The peak value of the test voltage is continuously adjustable from 2 - 20 kV or 2 - 24 kV. Positive or negative polarity of output voltage can be selected. A built-in voltage divider 1000:1 allows monitoring of the impulse output waveform during testing.
IPG 2025/ IPG 2436
HV - IMPULSE GENERATOR
2.5 kV - 20 kV - IPG 2025
2.5 kV - 24 kV - IPG 2436
According to |
|
IEC 60664 |
Testing impulse dielectric strength of components, insulations, air- and surface flash-over gaps |
VDE 0110 |
|
VDE 0411 |
|
VDE 0420 |
|
IEC 60335 : 2010 |
Insulation test of inductors and coils |
The HV - Impulse generators IPG 2025 and IPG 2436 create standard impulse voltages with waveform 1.2 / 50 µs acc. to IEC 60060. They are designed for testing impulse dielectric strength of components, insulations, air- and surface flash-over gaps according to the standards.
The peak value of the test voltage is continuously adjustable from 2 - 20 kV or 2 - 24 kV. Positive or negative polarity of output voltage can be selected. A built-in voltage divider 1000:1 allows monitoring of the impulse output waveform during testing.
The generators possess two high-voltage outputs with different source impedance. The HV output terminals are located beyond a dielectric cover with safety interlock. The transparent test cabinet prevents accidental contact with live parts of the test object and allows observation of the test object during testing.
The generator output possesses a current monitor detecting breakdown or flashover of the test object. The threshold of the current monitor is adjustable.
The generator excels by its compact design, simple handling and precise reproducibility of test impulses. It features a microprocessor-controlled user interface and a 7” touch screen unit for ease of use. The microprocessor allows the user to execute either standard test routines or a “user-defined” test sequence. A standard USB port provides the ability to print a summary of the test parameters to a USB stick.
Moreover all generator functions may be computer-controlled via the isolated optical interface. The software program IPG-REMOTE allows full remote control of the test generator via Ethernet light guide as well as documentation and evaluation of test results, according to the IEC 17025. To record definite impulses, it is equipped with an Impulse Recording Function (IRF).
Options |
IPG 2025 IPG 2436 |
|
|
PROTECTIVE COVER ON THE EQUIPMENT TOP |
|
With safety interlock switch connected to the safety interlock loop, red and green warning lamps installed, acc. to VDE 0104, built-in. |
See figure |
Type PA 503, Dimensions: W * H * D |
400 * 140 * 300 mm³ |
Type PA 505, Dimensions: W * H * D |
400 * 250 * 400 mm³ |
|
|
Software IPG-REMOTE, for remote control Or description of remote control commands |
|
With Impulse Recording Function (IRF) |
|
( XP, WIN7, WIN10 ) incl. 5m long light guide and PC Ethernet interface |
|
|
|
Version without a protective cover, current shunt Rm = 1W, |
|
BNC for measuring on the back |
TECHNICAL SPECIFICATIONS |
IPG 2025 |
IPG 2436 |
|
|
|
Mainframe |
|
|
Microprocessor controlled touch panel |
7”, capacitive |
|
Optical Ethernet Interface for remote control of the generator |
Optional |
|
Interface for saving reports |
USB |
|
External Trigger input/ output |
Switch/ 10V |
|
Connector for external safety interlock loop |
24 V= |
|
External red and green warning lamps |
24 V=, 40 mA |
|
Mains power |
90V – 264V / 50/60 Hz |
|
Dimensions of desktop case W * H * D |
450*180*500 mm3 |
|
Weight |
18kg |
|
|
|
|
HV-Generator section |
|
|
Peak value of impulse output voltage, adjustable, ± 5 % |
2.5 - 20 kV |
2.5 - 24 kV |
Waveform of impulse output voltage, acc. to VD 0433, IEC 60060 |
1.2/50 µs ± 30 % / 20 % |
|
Max. stored energy |
25 Joule |
36 Joule |
Energy storage capacitor Cs |
0.125 µF |
|
Resistor in series to the output HV1 Rs1 |
500W |
|
Resistor in series to the output HV2 Rs2 |
Standard 200W (opt. 40 or 50W) |
|
Output polarity, selectable |
pos / neg / alt |
|
|
|
|
Trigger : |
|
|
a) manual |
Push-button |
|
b) external Trigger input |
Switch |
|
c) internal, automatic, adjustable via test procedure |
1 - 1000 Impulse |
|
Repetition time, selectable |
5 - 1000 s |
|
|
|
|
CURRENT SENSE |
built-in |
|
Threshold value, selectable |
1 - 1250 µAs |
1 - 1500 µAs |
Impulse voltage divider, built-in |
1000:1 ± 2 % |
|
Mains synchronous triggering, phase shifting, digitally selectable |
0 - 359°, step 1° |
|
HV output, HV-OUT |
HV Plug |
|
|
|
|
Accessories: power cable, turn-key, instruction manual |
|