The high-voltage impulse generator PG 6-364 generates standard impulse voltages with waveforms 1.2/50 µs and 10/700 µs. The Output voltage is adjustable between 0.2 kV and 6 kV. The polarity of the output voltage is selectable. Positive, negative or alternating polarity of the output voltage can be preselected. The generator is designed for dielectric testing of components and systems as well as testing of the electromagnetic compatibility of electronic systems and devices acc. to CCITT K17/K20/K22, ITU-T/K44, IEC 61000-4-5, VDE 0847.
PARTNER:
MARKETS:
TEST STANDARDS:
PG 6-364
High voltage pulse generator
Lightning Surge |
1.2 / 50 µs |
|
Switching Surge |
10 / 700 µs |
|
|
0.5 / 700 µs |
(optional) |
|
1.0 / 700 µs |
(optional) |
|
0.5 / 1000 µs |
(optional) |
|
1.0 / 1000 µs |
(optional) |
|
100 / 700 µs |
(optional) |
According to |
CCITT-K17/K20/K22 |
ITU-T/K44 |
IEC 61000-4-5 |
VDE 0847 |
The high-voltage impulse generator PG 6-364 generates standard impulse voltages with waveforms 1.2/50 µs and 10/700 µs. The output voltage is adjustable between 0.2 kV and 6 kV. The polarity of the output voltage is selectable. Positive, negative or alternating polarity of the output voltage can be preselected.
The generator is designed for dielectric testing of components and systems as well as testing of the electromagnetic compatibility of electronic systems and devices acc. to CCITT K17/K20/K22, ITU-T/K44, IEC 61000-4-5, VDE 0847.
The PG 6-364 excels by its compact design, simple handling and precise reproducibility of test impulses. A built-in voltage divider 1000:1 allows monitoring of the impulse output waveform during testing.
The generator excels by its compact design, simple handling and precise reproducibility of test impulses. The generator uses maintenance-free semiconductor switches. It features a microprocessor controlled user interface and a 7” touch screen unit for ease of use. The microprocessor allows the user to execute either standard test routines or a “user-defined” test sequence. A standard USB port provides the ability to print a summary of the test parameters as well as the results to a USB stick.
Moreover, all generator functions may be computer controlled.
The software program PG-REMOTE allows full remote control of the test generator via fiber optic Ethernet interface as well as documentation and evaluation of test results, accordingly to the IEC 17025. To record definite impulses, it is equipped with an Impulse Recording Function (IRF)
External coupling networks designed for testing telecom equipment with up to 8 ports are available.
Options |
PG6-364 |
|
|
PC software for remote control |
PG-REMOTE |
PG Remote software test package, running under Microsoft Windows, for the external control of the device |
|
( XP, WIN7, WIN10 ) includes 5 m long fiber optic cable and Ethernet PC Interface |
|
|
|
External coupling/ decoupling network |
CDN |
4 wire/ 8 wire; 5kV acc. IEC 61000-4-5 |
CDN 504/ CDN 508 |
4 * 100 W |
KN100-4 |
|
|
PROTECTIVE COVER ON THE EQUIPMENT TOP |
PA |
With safety interlock switch, connected to the safety interlock loop, red and green warning lamps installed acc. VDE 0104 |
|
Type PA 503, Dimensions W * H * D |
400 * 140 * 300 mm³ |
Type PA 505, Dimensions W * H * D |
400 * 250 * 400 mm³ |
Version without protective cover |
|
|
|
ADDITIONAL WAVEFORMS, SEE DATASHEET |
PFN xx |
0,5/700 µs |
|
1,0/700 µs |
|
0,5/1000 µs |
|
1,0/1000 µs |
|
100/700 µs |
TECHNICAL SPECIFICATIONS |
PG 6-364 |
|
|
||
Mainframe |
||
Microprocessor controlled touch panel |
7”, capacitive |
|
Optical Ethernet Interface for remote control of the generator |
optional |
|
Interface for saving reports |
USB |
|
External Trigger input / output |
Switch / 10 V |
|
Connector for external safety interlock loop |
24 V = |
|
and external red and green warning lamps acc. to VDE 0104 |
230 V, 60W |
|
Mains power |
230V, 50/60 Hz |
|
Dimensions: desktop case W * H * D |
450 * 330 * 500 mm3 |
|
Weight |
35kg |
|
|
||
High- Voltage Pulse Generator: |
||
Impulse output voltage, adjustable ± 10% |
0.2 – 6.3 kV |
|
Output polarity, selectable |
pos / neg /alt |
|
Charging time |
< 15 sec |
|
Impulse voltage outputs of the rear panel |
coaxial |
|
Resistor in series to the output RS |
0 W / 25 W / 25 W |
|
Impulse voltage divider, built-in |
v= 1000:1 ± 2 %, 50 W |
|
|
||
Trigger: a) manual |
push button |
|
b) external Trigger input |
switch |
|
c) internal |
automatic |
|
|
||
Waveform of impulse output voltage |
Selectable |
|
Surge waveform, acc. CCITT / ITU-T K22, IEC |
1.2/50µs |
10/700µs |
Energy storage capacitor CS |
1.0 µF |
20 µF |
Max. stored energy WE |
20 J |
400 J |
Discharging resistor RE |
76 W |
50 W |
Damping Resistor RD |
13 W |
15 W |
Load capacitance CB |
0.03 µF |
0.2 µF |
|
||
Optional built-in Waveforms |
||
|
||
Impulse voltage 0.5/700 µs acc. to CNET |
PFN 0.5/700 |
|
Discharging resistor |
50 W |
|
Series resistor |
15 W |
|
Load capacitance |
0.007 µF |
|
Waveform front time/tail time |
0.5 / 700 µs |
|
|
||
Impulse voltage 1/700 µs |
PFN 1/700 |
|
Discharging resistor |
50 W |
|
Series resistor |
15 W |
|
Load capacitance |
0.015 µF |
|
Waveform front time/tail time |
1 / 700 µs |
|
|
||
Impulse voltage 0.5/1000 µs acc. to CNET |
PFN 0.5/1000 |
|
Discharging resistor |
75 W |
|
Series resistor |
15 W |
|
Load capacitance |
0.007 µF |
|
Waveform front time/tail time |
0.5 / 1000 µs |
|
|
Impulse voltage 1/1000 µs |
PFN 1/1000 |
Discharging resistor |
75 W |
Series resistor |
15 W |
Load capacitance |
0.015 µF |
Waveform front time/tail time |
1 / 1000 µs |
|
|
Impulse voltage 100/700 µs acc. to CCITT/ITU-T K17 |
PFN 100/700 |
Impulse output voltage, adjustable |
0.2-5.0 kV |
Discharging resistor |
50 W |
Series resistor |
15 W |
Load capacitance |
2.0 µF |
Waveform front time/tail time |
100 / 700 µs |
|
|
Accessories |
|
Mains cable, key, operation instructions |