30 MHz to 3 GHz | 7 probe models | Passive | SMA connection
RFS combines passive H-field and E-field scanner geometries for general PCB EMC development from 30 MHz to 3 GHz. Start with a larger-area probe to locate the source, then select a smaller head or electrode for the detailed scan.
MARKETS:
CATEGORIES:
TEST STANDARDS:
Select Options/Sizes:
RFS combines passive H-field and E-field scanner geometries for general PCB EMC development from 30 MHz to 3 GHz. Start with a larger-area probe to locate the source, then select a smaller head or electrode for the detailed scan.
All published scalar specifications are consolidated below. Click each small response, correction-curve or geometry image to open the full-size image in a new tab. Missing numeric resolution or length values are not inferred from model names or photographs.
The RFS set includes RFS-B 3-2, RFS-E 03 and RFS-R 50, one SMA-SMA 1 m measuring cable and a case described as holding four RFS probes. The package contains three probes, not four.
| Included item | Quantity |
|---|---|
| RFS-B 3-2, Scanner Probe 30 MHz up to 3 GHz | 1x |
| RFS-E 03, Scanner Probe 30 MHz up to 3 GHz | 1x |
| RFS-R 50, Scanner Probe 30 MHz up to 3 GHz | 1x |
| SMA-SMA 1 m, SMA-SMA Measuring Cable | 1x |
| RFS case, System Case for 4 RFS-probes | 1x |
Frequency-response plots show the model-specific response. H-field, E-field and current correction curves are separate quantities: use the appropriate curve, units, distance and setup when converting receiver voltage to a field or current estimate. A probe is directional; keep the sensing orientation and probe-to-DUT spacing consistent between scans. The source tables use both "SMA male plug" and "SMA male jack" wording; verify the mating cable rather than silently treating the terms as different probe genders.
| Product | Document |
|---|---|
| RFS-R 50 | RFS-R 50 - Datasheet |
| RFS-R 3-2 | RFS-R 3-2 - Datasheet |
| RFS-R 0.3-3 | RFS-R 0.3-3 - Datasheet |
| RFS-B 3-2 | RFS-B 3-2 - Datasheet |
| RFS-B 0.3-3 | RFS-B 0.3-3 - Datasheet |
| RFS-E 03 | RFS-E 03 - Datasheet |
| RFS-E 10 | RFS-E 10 - Datasheet |
| Family | Models | Coverage | Field types | Choose for |
|---|---|---|---|---|
LFS |
1 | 100 kHz-50 MHz | H | Low-frequency switching-current and magnetic-field mapping. |
RFS |
7 | 30 MHz-3 GHz | H and E | General PCB investigations with large-area and fine-resolution geometries. |
XFS |
4 | 30 MHz-6 GHz | H and E | PCB near-field mapping when coverage above 3 GHz is needed. |
The passive scanner probes below have model-specific SMA connections and no power supply in their published specification. ICR near-field microprobes are a separate precision-probe class; use the existing ICR near-field microprobe range when micrometer-scale sensing is needed.