The capacitive Coupling-/Decoupling Network CDN 10216 & 12216 is used in combination with the Surge generators PG 7-250, PG 10-504 or PG 12-804 and allows superimposition of surge test pulses to the single-phase power supply voltage of the device under test. The test set-up is suitable for immunity testing of electronic systems and devices according to IEC 61000-4-4, IEC 61000-4-5 and IEEE 587.
PARTNER:
MARKETS:
TEST STANDARDS:
CDN 10216 / 12216
Main |
240 V / 16 A (option for 480V) |
Surge |
1.2/50 µs: 10 / 12kV |
|
8/20 µs: 5.0 / 6.0kA |
Burst |
5.0 kV, 5/50 ns |
According to |
IEC 61000-4-4 |
IEC 61000-4-5 |
IEEE 587 |
The capacitive Coupling-/Decoupling Network CDN 10216 / 12216 is used in combination with the Surge generators PG 7-250, PG 10-504 or PG 12-804 and allows superimposition of surge test pulses to the single-phase power supply voltage of the device under test.
The test set-up is suitable for immunity testing of electronic systems and devices according to IEC 61000-4-4, IEC 61000-4-5 and IEEE 587.
The CDN contains the coupling impedances 18 µF and 9 µF + 10 W for the surge generator and the decoupling impedances for the power supply lines.
Additional coupling mode: „coupling to both lines“ with 10 W and two capacitors 9 µF is provided.
Coupling mode can be selected from the front panel of the generator. Remote control commands are transmitted from the generator to the Coupling-/Decoupling Network by use of a control cable.
The coupling impedance and the coupling path selected are indicated on the front panel of the coupling-/decoupling network.
Technical specification: |
CDN 10216 |
CDN 10216 |
Nominal voltage |
240 V, 50/60 Hz |
|
Nominal current AC/DC |
16 A» / 10 A= |
|
Series inductors to the mains power supply |
100 µH |
|
max. test voltage Surge, 1.2/50 µs: |
10 kV |
12 kV |
max. test voltage Burst, 5/50 ns: |
5.0 kV |
|
Coupling impedance for the surge generator |
18 µF 9 µF + 10 W |
|
Coupling impedance for the burst generator |
33 nF |
|
|
|
|
Coupling mode, selectable, for the surge generator |
line to line via 18 µF or line to ground 9 µF + 10 W both lines to ground via 2*9 µF+10 W |
|
Coupling mode, selectable, for the burst generator |
line to ground via 33 nF |
|
|
|
|
Impuls Synchronisation |
Mains, Extern |
|
Burst Input |
Fischer |
|
Surge Input |
4 mm Bush |
|
|
|
|
Mains power |
90V - 264V , 50/60 Hz |
|
Dimensions: desk top case W * H * D |
450*180*500 mm3 |
|
Weight |
25 kg |
|
|
|
|
Option: |
||
Nominal voltage Coupling |
480 V, 50/60 Hz ANSI |