CDN 5416 / 7416 / 10416 / 12416, 3-Phase, 16 Amp, Surge and EFT/burst, Coupling Decoupling Network

The capacitive Coupling-/Decoupling Networks CDN 5416/7416/10416/12416 are used in combination with the Multi-CE5 or the Surge generators PG 7-250, PG 10-504, PG 12-804 and allow superimposition of surge and burst test pulses to the 3-phase mains voltage of the device under test.

Data Sheet

SPECIFICATIONS

CDN 5416 / 7416 / 10416 / 12416

  

 


Coupling-/Decoupling Network 

   

 

 

Main

3* 400 V / 16 A  (option for 690V)

Surge

1.2/50 µs: 5.0 / 7.0 / 10 / 12kV

 

8/20 µs: 2.5 / 3.0 / 5.0 / 6.0kA

Burst

5.0 kV, 5/50 ns

 

 

According to

IEC 61000-4-4

IEC 61000-4-5

IEEE 587

 

 

 The capacitive Coupling-/Decoupling Networks CDN 5416/ 7416/ 10416/ 12416 are used in combination with the Multi CE5 or the Surge generators PG 7-250, PG 10-504, PG 12-804 and allow superimposition of surge and burst test pulses to the 3-phase mains voltage of the device under test.

 

The test set-up is suitable for surge immunity testing of electronic systems and devices.

The CDN 5416/ 7416/ 10416/ 12416 contains the coupling impedances 18 µF and 9 µF + 10 W for the surge generator and 33 nF for the burst generator and the decoupling impedances for the 3-phase power supply lines.

 

Coupling mode can be selected from the front panel of the generator. Remote control commands are transmitted from the generator to the Coupling-/Decoupling Network by use of a control cable.

 

 

 

Technical specification:

CDN 5416

CDN 7416

CDN 10416

CDN 12416

Nominal voltage

3 * 400 V, 50/60 Hz

Nominal current AC/DC

16 A» / 10 A=

Series inductors to the

mains power supply

100 µH

max. test voltage Surge, 1.2/50 µs:

5.0 kV

7.0 kV

10 kV

12 kV

max. test voltage Burst, 5/50 ns:

5.0 kV

Coupling impedance for the

surge generator

18 µF

9 µF + 10 W

Coupling impedance for the

burst generator

33 nF

 

 

Coupling mode, selectable, for the surge generator

line to line via 18 µF or

line to ground 9 µF + 10  
(Option for ANSI)

Coupling mode, selectable, for the

burst generator

line to ground via 33 nF

 

 

Impuls Synchronization

Mains, Extern

Burst Input

Fischer

Surge Input

4 mm Bush

 

 

Mains power

90V - 264 V, 50/60 Hz

Dimensions:     desktop case W * H * D

450*180*500 mm3

450*310*500 mm3

Weight

30 kg

58 kg

Option:

Nominal voltage

Coupling

3 * 690 V, 50/60 Hz

 

ANSI

 

 

 