SY 9223-50561-1, Symmetrical Transformer, 50 to 100 Ohms acc. EN 50561-1

  • Symmetrical transformer
  • Transforms an unsymmetrical 50 Ω signal into a symmetrical signal with an impedance of 100 Ω
  • Attenuates the power by 8 dB
  • Acc. to EN 50561-1:2012, chapter 9.2. Figure 4 shows the setup, figure 5 shows the principle diagram

Overview PLC Measurement-System EN 50561-1

Data Sheet

SPECIFICATIONS

 

SY 9223-50561-1, Symmetrical Transformer, 50 to 100 Ohms acc. EN 50561-1 


Description

SY 9223-50561-1 is a symmetrical transformer that provides impedance transformation and a specified insertion loss. It transforms an unsymmetrical 50 Ω signal into a symmetrical signal with an impedance of 100 Ω and attenuates the power by 8 dB. It belongs to a measurement setup according to EN 50561-1, chapter 9.2.

Figure 1 shows the setup.  The 100 Ω to 50 Ω balun belongs to a collection of measurement equipment to analyze power line communication devices. The part which determines the frequency response is a 2:1 SMD broadband transformer. A resistive attenuator has been added to the unsymmetrical side to get the necessary insertion loss demanded by the measurement setup. The SY 9223-50561-1 has a real flat frequency response of typically

 

Frequency range: 1.6 MHz ... 30 MHz
Insertion loss: 8 dB ± 0.2 dB
Symmetrical impedance: 100 Ω
Unsymmetrical impedance: 50 Ω
Max. input power: 200 mW
Proof voltage against housing: >500 VDC
Unsymmetrical connector: BNC jack 50 Ω
Symmetrical terminals: 4 mm safety laboratory jack
Length: 125 mm
Width: 104 mm
Hight: 50 mm
Weight: ca. 270 g

 PDF Overview PLC Measurement-System EN 50561-1

 

 

OTHER PRODUCTS IN THE SAME CATEGORY: