CDN S-type - Screened cables

The Coupling- / Decoupling Networks are used to inject common-mode disturbances to Equipment under Test (EuT). Further, the CDNs provide sufficient decoupling between Auxiliary Equipment (AE) and disturbance signal. The requirements for CDN and their application are described in the standard IEC 61000-4-6 (Immunity to conducted disturbances, induced by radio-frequency fields). CDNs have a common mode impedance of 150 Ohm and are available for a multitude of cable types and connectors.

CDN Overview

SPECIFICATIONS

 

CDN S Type - Screened (Shielded) Coupling Decoupling Network

 

Coupling Decoupling Network (CDN) built to the requirements of IEC 61000-4-6. CDNs have a common mode impedance of 150 Ohm. S Type are for testing: 

    • Coax Cables
    • Screened or shielded lines
    • Each CDN incl. 2 Shorting adapters

  

Model Frequency Range No. Lines Voltage Current Connector
CDN S1 BNC 0.01 - 230 MHz 1 100 VAC / 150 VDC 0.25 Amp BNC 50 Ω
CDN S1 BNC 75 0.01 - 230 MHz 1 100 VAC / 150 VDC 0.25 Amp BNC 75 Ω
CDN S2 XLR3-1 0.01 - 230 MHz 2 100 VAC / 150 VDC 0.25 Amp XLR3-1 GND:PIN1
CDN S2 XLR3-3 0.01 - 230 MHz 2 100 VAC / 150 VDC 0.25 Amp XLR3-1 GND:PIN3
CDN S4 4xBNC 0.01 - 230 MHz 4 100 VAC / 150 VDC 0.25 Amp 4- BNC 50 Ω
CDN S4 XLR4 0.01 - 230 MHz 4 100 VAC / 150 VDC 0.25 Amp XLR4 female
CDN S4 DIN5-1 0.01 - 230 MHz 4 100 VAC / 150 VDC 0.25 Amp DIN5 GND:PIN1
CDN S8 RJ45 0.01 - 230 MHz 8 100 VAC / 150 VDC 0.25 Amp RJ45
CDN S9 SUBD 0.01 - 230 MHz 9 100 VAC / 150 VDC 0.25 Amp Sub-D9 pin
CDN S9 USB3.0 0.01 - 230 MHz 9 100 VAC / 150 VDC 0.25 Amp  USB 3.0
CDN S15 VGA 0.01 - 230 MHz 15 100 VAC / 150 VDC 0.25 Amp Sub-D15 HD (VGA)
CDN S19 HDMI 0.01 - 230 MHz 19 100 VAC / 150 VDC 0.25 Amp HDMI
CDN S24 USB-C 0.01 - 230 MHz 24 100 VAC / 150 VDC 0.25 (5) Amp USB-C
CDN S25 SUBD 0.01 - 230 MHz 25 100 VAC / 150 VDC 0.25 Amp Sub-D25 pin

 

 

 

 

 