The surge current testing device HCS 3-30 is used for surge current testing of capacitor windings. The capacitor to be tested is on an adjustable voltage, 0,005 - 3000 V, charged and then discharged via a triggerable switch.
CAPACITOR DISCHARGE TEST SETUP
· Loading voltage 3kV · Current amplitude 2 x 15 kA · Optical impulse trigger |
The surge current test setup is used for HCS3-30 surge current testing of capacitor windings. The tested capacitor is an adjustable voltage, 0.05 - 3000 V charged and then discharged through a triggerable switch.
The capacitor discharge test setup essentially consists of an electronically controlled high- voltage charger (additional device), a high voltage triggerable switch trigger pulse amplifier and a current measuring device.
Technical specification |
HCS 3-30 |
|
|
max. allowable charging voltage |
3.0 kV ± 2% |
Polarity of the charging voltage |
positive |
Loading resistor: 15 * 10W-65W |
build-in |
|
|
Max. current amplitude, for one switch |
max. 15 kA |
Max. current amplitude, for both switches in parallel |
max. 30 kA |
|
|
Max. charging transfer over the switch |
2.0 As |
Impulse current resistor for detecting the discharge current |
2 * 1 mW, 10 kA |
|
|
Impulse output: |
High current connectors, at the rear site |
Attention! The high current outputs are not touch-proof isolated! The device may be operated only in the installed condition, where the high current outputs are touch-proof covered and protected against touch! |
|
|
|
Impulse trigger: 0/10V, optical converter, light guide input |
build in |
Ignition booster: appr. 6 * 2.5A/0.5A, 100µs |
build in |
High current switch:2 * 3 Thyristors |
build in |
|
|
Power supply |
230 V / 50-60 Hz |
Dimension: 19"-case |
553*470*600 mm3 |
Wight |
35kg |
The control of HCS 3 and the HV loading device is not included in this test set up.
Because it is not possible to build in a pulse current limiters in the device, we cannot assume any lifetime warranty for the thyristors and freewheeling diodes.
|
|