HCS 3-30 CAPACITOR DISCHARGE TEST SETUP 2 x 15kA

The surge current testing device HCS 3-30 is used for surge current testing of capacitor windings. The capacitor to be tested is on an adjustable voltage, 0,005 - 3000 V, charged and then discharged via a triggerable switch.

PARTNER:

TEST STANDARDS:

Data Sheet

SPECIFICATIONS

HCS 3-30 

 

CAPACITOR DISCHARGE TEST SETUP

 

 

·         Loading voltage 3kV

·         Current amplitude 2 x 15 kA

·         Optical impulse trigger

 The surge current test setup is used for HCS3-30 surge current testing of capacitor windings. The tested capacitor is an adjustable voltage, 0.05 - 3000 V charged and then discharged through a triggerable switch.

 

  

 

The capacitor discharge test setup essentially consists of an electronically controlled high- voltage charger (additional device), a high voltage triggerable switch trigger pulse amplifier and a current measuring device.

 

Technical specification

HCS 3-30

 

max. allowable charging voltage

3.0 kV ± 2%

Polarity of the charging voltage

positive

Loading resistor:      15 * 10W-65W

build-in

 

Max. current amplitude, for one switch

max. 15 kA

Max. current amplitude, for both switches in parallel

max. 30 kA

 

Max. charging transfer over the switch

2.0 As

Impulse current resistor for detecting the discharge current

2 * 1 mW, 10 kA

 

Impulse output:

High current connectors,

at the rear site

Attention! The high current outputs are not touch-proof isolated!

The device may be operated only in the installed condition, where the high current outputs are touch-proof covered and protected against touch!

 

Impulse trigger:        0/10V, optical converter, light guide input

build in

Ignition booster:       appr. 6 * 2.5A/0.5A, 100µs

build in

High current switch:2 * 3 Thyristors

build in

 

Power supply

230 V / 50-60 Hz

Dimension:   19"-case

553*470*600 mm3

Wight

35kg

 

The control of HCS 3 and the HV loading device is not included in this test set up.

 

 