CDG 7000-200 Conducted Immunity, 4 kHz - 400MHz, 200Watts

CDG 7000-200 Conducted Immunity, 4 kHz - 400MHz, 200Watts

CDG 7000 Conducted Immunity, (4)10 kHz - 400MHz

CDG 7000 Conducted Immunity, (4)10 kHz - 400MHz

CDG 7000-E Conducted Immunity Generator, (4)9 kHz - 1 GHz , No internal Amplifier

CDG 7000-E Conducted Immunity Generator, (4)9 kHz - 1 GHz , No internal Amplifier

CDG 7000-75-10 Magnetic Immunity, 10 kHz - 400MHz, IEC 61000-4-39

CDG 7000-75-10 Magnetic Immunity, 10 kHz - 400MHz, IEC 61000-4-39

MAG 1000, 120A/m CW, 1100Am Short Duration, Power Frequency Magnetic Field

MAG 1000, 120A/m CW, 1100Am Short Duration, Power Frequency Magnetic Field

Injection Clamp Kits (ICK) EM and BCI Clamps

Injection Clamp Kits (ICK) EM and BCI Clamps

CDG CDN Coupling / Decoupling Networks

CDG CDN Coupling / Decoupling Networks

CDG EMCL- NW 10 / MN-1 EM Clamp Matching Network

CDG EMCL- NW 10 / MN-1 EM Clamp Matching Network

CDG CDN EMCL-20 / CDG CDN EMCL-35 EM Clamp

CDG CDN EMCL-20 / CDG CDN EMCL-35 EM Clamp

CDG CDN ABCL-20 Decoupling Clamp

CDG CDN ABCL-20 Decoupling Clamp

CDG CDN ABCL-35 Decoupling Clamp

CDG CDN ABCL-35 Decoupling Clamp

CDG CDN BCI-P1 Bulk Current Injection Probe 1 MHz – 400 MHz

CDG CDN BCI-P1 Bulk Current Injection Probe 1 MHz – 400 MHz

Products

CDG 7000-200 Conducted Immunity, 4 kHz - 400MHz, 200Watts

  • Generator frequency range CDG 7000-200 covers 100 kHz – 400 MHz, 
  • CDG 7000-200 supports BCI testing up to 500 mA closed loop with the appropriate accessories
  • Optional CDG 7000-200-4 amplifier extends the CDG 7000-200 system downward to 4 kHz – 1 MHz
  • EUT monitoring, SCPI control of other equipment

CDG 7000 Conducted Immunity, (4)10 kHz - 400MHz

  • Integrated RF signal generator, RF power amplifier, 3-channel RF voltmeter, and directional coupler
  • Generator frequency range from 9 kHz to 1.2 GHz, usable from 4 kHz
  • RF amplifier configurations available from 25 W to 200 W
  • Frequency coverage options from 10 kHz to 400 MHz, depending on model
  • HELIA 7-Basic software included for test control, reporting, and EUT monitoring
  • External amplifier expansion through the second generator output
  • SCPI command set for integration into automated EMC software systems

CDG 7000-E Conducted Immunity Generator, (4)9 kHz - 1 GHz , No internal Amplifier

The CDG 7000-E is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields - including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. Use an external Amplifier you already have or one that matches your application. 

  • The compact device comprises an RF signal generator, a 3-channel RF voltmeter, and a directional coupler.
  • Frequency range of the generator/power meter (4 kHz): 9 kHz – 1200 MHz
  • The frequency range of the directional coupler: 10 kHz – 1000 MHz, 200 W 
  • Depending on ext. amplifier:  IEC/EN 61000-4-6, IEC 60601-1-2 Ed. 4.1,  IEC 61000-4-39, MIL 461 CS 114, ISO 11452-4, ...

CDG 7000-75-10 Magnetic Immunity, 10 kHz - 400MHz, IEC 61000-4-39

The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields - including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. IEC 60601-1-2 calling out IEC 61000-4-39 magnetic immunity for close proximity testing requirements can also now be met with the 10 kHz unit. 

MAG 1000, 120A/m CW, 1100Am Short Duration, Power Frequency Magnetic Field

MAG 1000

  • 1-120A/m Contiunus testing
  • 100-1100A/m Short Duration 1-3sec
  • Test either 50Hz & 60Hz Selectable
  • 1m square Loop

Injection Clamp Kits (ICK) EM and BCI Clamps

Absolute EMC offers an assortment of injection test kits for the use of conducted immunity. The kits can be used with many available conducted immunity systems, including the Schlöder CDG 7000, to make selection and setup easy. All calibration fixtures, injection clamps, attenuators, and termination resistors necessary for meeting the requirements of conducted immunity systems. All all-in-one systems are covered. 

CDG CDN Coupling / Decoupling Networks

The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields - including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price.

CDG EMCL- NW 10 / MN-1 EM Clamp Matching Network

EMCL- NW 10 / MN-1 Matching Network • For use with the EMCL-20 in the frequency range 10 kHz – 150 kHz • For use with the CDN BCI-P1 in the frequency range 10 kHz – 150 kHz

CDG CDN EMCL-20 / CDG CDN EMCL-35 EM Clamp

EM Clamp for immunity tests IEC / EN 61000-4-6 Ed. 4.0 • EM Clamp for immunity testing of cables with up to 20 (35) mm diameter • High coupling factor: less than 15 watts amplifier output power is required to obtain a test level of 10 V • Calibration unit and calibration data are supplied with each unit.

CDG CDN ABCL-20 Decoupling Clamp

CDN ABCL-20 Decoupling Clamp for immunity according to IEC / EN 61000-4-6 Ed. 4.0 100 kHz – 1000 MHz Features: For additional decoupling at immunity testing according to IEC / EN 61000-4-6 Suitable for cables up to 20mm diameter

CDG CDN ABCL-35 Decoupling Clamp

CDN ABCL-35 Decoupling Clamp for immunity according to IEC / EN 61000-4-6 Ed. 4.0 100 kHz – 1000 MHz Features: For additional decoupling at immunity testing according to IEC / EN 61000-4-6 Suitable for cables up to 20mm diameter

CDG CDN BCI-P1 Bulk Current Injection Probe 1 MHz – 400 MHz

BCI-P1 Bulk Current Injection Probe 10 kHz – 400 MHz - Meets specifications of ISO 11452-4:2005 and IEC 61000-4-6 - Frequency range from 1 MHz up to 400 MHz - Designed for automotive BCI testing - Low insertion loss (1MHz - 400MHz) to test bellow 1MHz (IEC/DO/MIL) see CDN BCI-P1_MT-1