RW-CE7: 7kV Ringwave, 5µs 100 kHz

High-voltage pulse generator producing Ring Wave 0.5 µs / 100 kHz acc. to IEEE 587. The output peak voltage can be preset continuously from 0.2 - 7 kV. Rise time 0.5µs to the first peak, ringing frequency 100 kHz. A built-in voltage divider allows the monitoring of the output voltage waveform. The generator comprises an electronically regulated high-voltage power supply, an energy storage capacitor, a high-voltage/high-current switch, a pulse forming network and control- and monitoring unit. Moreover, the generator includes a Coupling-/Decoupling Network (CDN) for single-phase power supply lines.

Data Sheet

SPECIFICATIONS

RW CE7

Ring Wave EMC-tester

 

 IEC 61000-4-12, IEC 1008-1

 

 

According to

   

IEC 61000-4-12

Ringwave Generator 7kV

 

The RW-CE7 is a compact EMC test unit designed for testing electromagnetic immunity against pulsed and conducted interference. Demonstrating such immunity is generally a requirement for compliance with the European EMC directive, a necessary step leading to the CE mark.

 

Included is the high-voltage pulse generator producing Ring Wave 0.5 µs / 100 kHz acc. to IEC 61000-4-12. The output peak voltage can be present continuously from 0.25 - 7 kV. Rise time 0.5µs to the first peak, ringing frequency 100 kHz.

 

Additional Coupling-/Decoupling Networks covering three-phase power supply lines, DC supply lines, and signal lines are also available, as well as a Capacitive Coupling Clamp for coupling to shielded interconnection lines.

 

The RW-CE7 excels by its compact design, simple handling and precise reproducibility of test impulses. It features a microprocessor-controlled user interface and a 7” touch screen unit for ease of use. The microprocessor allows the user to execute either standard test routines or a “user-defined” test sequence. A standard USB port provides the ability to print a summary of the test parameters as well as the results to a USB stick.

 

The software program CE-REMOTE allows full remote control of the test generator via Ethernet light guide as well as documentation and evaluation of test results, accordingly to the IEC 17025. To record definite impulses, it is equipped with an Impulse Recording Function (IRF).

 

Moreover all generator functions including the built-in Coupling-/Decoupling Network, maybe computer-controlled via the isolated optical interface.


System configuration

 

The Multi-CE7 and its sub-units are available in different configurations:

 

Variations

Description

Multi-CE7 1

including SURGE and BURST

Multi-CE7 2

including SURGE, BURST, and POWER FAIL SWITCH

EFTG-CE5

Stand-alone BURST generator

CWG-CE7

RW-CE7

Stand-alone SURGE generator

Stand-alone RING WAVE generator

PFS-CE-16

Stand-alone POWER FAIL SIMULATOR

Including a power fail switch and a variable power source

 

 

It is possible to build all devices in a 19” rack cabinet.

 

 

 

 

Options

RW CE7

 

Software CE-REMOTE Test, for remote control

With Impulse Recording Function (IRF)

( XP, WIN7, WIN10 ) incl. 5 m fiber optic cable and PC Ethernet interface

 

 

TECHNICAL SPECIFICATIONS

Multi CE7

 

Mainframe

Microprocessor controlled touch panel

7”, capacitive

Optical Ethernet Interface for remote control of the generator

optional

Interface for saving reports

USB

External trigger input/ output

Switch/ 10 V

Coupling-/decoupling network for power supply lines

L1, N, PE (ISO, optional ANSI)

Nominal voltage, nominal current

250 V, 16 A » / 16 A =

Coupling impedance (depending on the generator)

33 nF / 18 µF / 9µF+10W

Connector for external safety interlock loop

24 V =

External red and green warning lamps

230 V, 60W

Mains power

90V - 264V, 50/60 Hz

Dimensions of desktop case W * H * D

450*330*500 mm3

Weight

25 kg

 


 

 

 

RINGWAVE acc. to IEC 61000-4-12: 2004

Impulse output voltage, adjustable

0.25 - 7.0 kV ± 10 %

Output waveform acc. to IEC 61000-4-12

0.5 µs /100 kHz

Oscillation frequency

100 kHz ± 10%

Voltage rise time to the first peak (open)

0.5 µs ± 30%

Current rise time to the first peak (short)

<= 1 µs

Decaying voltage

0,4 < Ratio of Pk2 to Pk1 < 1,1

0,4 < Ratio of Pk3 to Pk2 < 0,8 0,4 < Ratio of Pk4 to Pk3 < 0,8

Polarity of output voltage

pos / neg, selectable

Maximum stored energy

12 J

Repetition rate, max.

60 transients per minute

 

High-voltage output HV-OUT, impedance selectable:

PFN 1: Series resistor

12 W (10+2 W)

PFN 2: Series resistor

30 W (10+20 W)

Impulse voltage divider integrated

ratio = 1000:1 ± 5%

 

Mains synchronous trig.: Phase shifting, digitally selectable

0 - 360 ° ±5°

 

 

 

OTHER PRODUCTS IN THE SAME CATEGORY: