PG 12 - 1440, High Voltage Pulse Generator, 10/700µs, 1.2/50µs, 12kV

The high-voltage impulse generator PG 12-1440 standard impulse voltages with waveforms 1.2/50 µs or 10/700 µs. The output voltage is adjustable between 0.5 kV and 12 kV. The polarity of the output voltage is selectable. Positive, negative or alternating polarity of the output voltage can be preselected.

SPECIFICATIONS

PG 12 - 1440

  

 

 

High voltage pulse generator

   

  • Lightning surge:
  • 1.2 / 50 µs
  • 0.5 - 12 kV
 
  • Switching surge:
  • 10 / 700 µs
  • 0.5 - 12 kV

 

 

 

According to

CCITT-K17/K20/K22

ITU-T/K44

IEC 61000-4-5

VDE 0847

 

 

The high-voltage impulse generator PG 12-1440 standard impulse voltages with waveforms 1.2/50 µs or 10/700 µs. The output voltage is adjustable between 0.5 kV and 12 kV. The polarity of the output voltage is selectable. Positive, negative or alternating polarity of the output voltage can be preselected.

It is designed for dielectric testing of components and systems acc. to CCITT-K17/K20-K22, ITU-T/K44, IEC 61000-4-5, VDE 0847. The pulse forming network is referred to as ground. The high-voltage output is available at a coaxial connector.

A built-in voltage divider 1000:1 allows monitoring of the impulse output waveform during testing.

 

PG 12-1440 features a microprocessor-controlled user interface and a 5” touch screen unit for ease of use. The microprocessor allows the user to execute either standard test routines or a “user-defined ” test sequence. A standard USB port provides the ability to print a summary of the test parameters to a USB stick.

 

External coupling units with 4*25W designed for testing telecom equipment at reduced output voltage are available. They are controlled from the generator via optical-link.

 

The software program HILO-REMOTE allows full remote control of the test generator via Ethernet light guide as well as documentation and evaluation of test results, accordingly to  the IEC 17025. To record definite impulses, it is equipped with an Impulse Recording  Function (IRF) Moreover, all generator functions may be computer-controlled via the isolated optical interface.

 

 

 

TECHNICAL SPECIFICATIONS

PG 12-1440

 

 

Mainframe:

 

Microprocessor controlled touch panel

5”, 800X480, 24 bit

Optical Ethernet Interface for remote control of the generator

optional

Interface for saving reports

USB

External Trigger input

switch

External Trigger output

10 V at 1 kW

Connector for external safety interlock loop

24 V =

External red and green warning lamps

230 V, 60W

Mains power

230 V, 50/60 Hz

Dimensions of desk top case W * H * D

555*604*600 mm3

Weight

65 kg

 

 

High-voltage pulse generator

 

Impulse output voltage, adjustable

0.2-12.0 kV ± 5%

Polarity of output voltage/current, selectable

pos/neg/alt

Charging time

< 25 sec

 

 

Pulse forming networks:

selectable

 

 

a)Impulse voltage 1.2/50µs acc. to CCITT / ITU-T K22

PFN 1.2/50

Energy storage capacitor

1.0 µF / 12 kV

Discharging resistor

76 W

Series resistor

13 W

Load capacitor

33 nF

Wave form: front time/tail time

1.2 / 50 µs ± 30%/±20%

 

 

b)Impulse voltage    10/700µs acc. to    CCITT / ITU-T K17/K20, IEC 1000-4-5

PFN 10/700

Energy storage capacitor

20 µF / 14.6 kV

Discharging resistor / Series resistor

50 W / 15 W

Load capacitance

0.2 µF

Wave form: front time/tail time

10 / 700 µs ± 20%

 

 

Direct pulse voltage output on the rear panel

HV-Out coaxial

Coupling impedance output A and B

2 x 25 W

for connection of external coupling devices Monitor output for pulse output voltage

ratio = 1000 : 1 ± 5%

 

 

Option :

 

Software HILO-REMOTE, for remote control

 

With Impulse Recording Function (IRF)

 

( XP, WIN7, WIN8, WIN10 ) incl. 5m long light guide and PC Ethernet interface

 

Option :

 

Description of Remote control commands

 

Incl. Ethernet PC-interface and 5m long light-guide

 

Option :

 

Different test cabinets

 

 

 

 

 

OTHER PRODUCTS IN THE SAME CATEGORY:
Loading...