The high-voltage impulse generator PG 12-1440 standard impulse voltages with waveforms 1.2/50 µs or 10/700 µs. The output voltage is adjustable between 0.5 kV and 12 kV. The polarity of the output voltage is selectable. Positive, negative or alternating polarity of the output voltage can be preselected.
PARTNER:
MARKETS:
TEST STANDARDS:
PG 12 - 1440
High voltage pulse generator
|
According to |
CCITT-K17/K20/K22 |
ITU-T/K44 |
IEC 61000-4-5 |
VDE 0847 |
The high-voltage impulse generator PG 12-1440 standard impulse voltages with waveforms 1.2/50 µs or 10/700 µs. The output voltage is adjustable between 0.5 kV and 12 kV. The polarity of the output voltage is selectable. Positive, negative or alternating polarity of the output voltage can be preselected.
It is designed for dielectric testing of components and systems acc. to CCITT-K17/K20-K22, ITU-T/K44, IEC 61000-4-5, VDE 0847. The pulse forming network is referred to as ground. The high-voltage output is available at a coaxial connector.
A built-in voltage divider 1000:1 allows monitoring of the impulse output waveform during testing.
PG 12-1440 features a microprocessor-controlled user interface and a 5” touch screen unit for ease of use. The microprocessor allows the user to execute either standard test routines or a “user-defined ” test sequence. A standard USB port provides the ability to print a summary of the test parameters to a USB stick.
External coupling units with 4*25W designed for testing telecom equipment at reduced output voltage are available. They are controlled from the generator via optical-link.
The software program HILO-REMOTE allows full remote control of the test generator via Ethernet light guide as well as documentation and evaluation of test results, accordingly to the IEC 17025. To record definite impulses, it is equipped with an Impulse Recording Function (IRF) Moreover, all generator functions may be computer-controlled via the isolated optical interface.
TECHNICAL SPECIFICATIONS |
PG 12-1440 |
|
|
Mainframe: |
|
Microprocessor controlled touch panel |
5”, 800X480, 24 bit |
Optical Ethernet Interface for remote control of the generator |
optional |
Interface for saving reports |
USB |
External Trigger input |
switch |
External Trigger output |
10 V at 1 kW |
Connector for external safety interlock loop |
24 V = |
External red and green warning lamps |
230 V, 60W |
Mains power |
230 V, 50/60 Hz |
Dimensions of desk top case W * H * D |
555*604*600 mm3 |
Weight |
65 kg |
|
|
High-voltage pulse generator |
|
Impulse output voltage, adjustable |
0.2-12.0 kV ± 5% |
Polarity of output voltage/current, selectable |
pos/neg/alt |
Charging time |
< 25 sec |
|
|
Pulse forming networks: |
selectable |
|
|
a)Impulse voltage 1.2/50µs acc. to CCITT / ITU-T K22 |
PFN 1.2/50 |
Energy storage capacitor |
1.0 µF / 12 kV |
Discharging resistor |
76 W |
Series resistor |
13 W |
Load capacitor |
33 nF |
Wave form: front time/tail time |
1.2 / 50 µs ± 30%/±20% |
|
|
b)Impulse voltage 10/700µs acc. to CCITT / ITU-T K17/K20, IEC 1000-4-5 |
PFN 10/700 |
Energy storage capacitor |
20 µF / 14.6 kV |
Discharging resistor / Series resistor |
50 W / 15 W |
Load capacitance |
0.2 µF |
Wave form: front time/tail time |
10 / 700 µs ± 20% |
|
|
Direct pulse voltage output on the rear panel |
HV-Out coaxial |
Coupling impedance output A and B |
2 x 25 W |
for connection of external coupling devices Monitor output for pulse output voltage |
ratio = 1000 : 1 ± 5% |
|
|
Option : |
|
Software HILO-REMOTE, for remote control |
|
With Impulse Recording Function (IRF) |
|
( XP, WIN7, WIN8, WIN10 ) incl. 5m long light guide and PC Ethernet interface |
|
Option : |
|
Description of Remote control commands |
|
Incl. Ethernet PC-interface and 5m long light-guide |
|
Option : |
|
Different test cabinets |
|
|