CG 50LR10100R, 50kHz/500kHz - 108MHz for LISN & 10MHz ~6GHz for RE, Comb Generator

  • Frequency Range
  • Conducted Emissions: 50kHz/500kHz ~ 108MHz for DC LISN
  • Radiated Emissions:
  •    50kHz/500kHz ~30MHz for RE with Monopole Antenna
  •    10MHz/100MHz ~1G for RE
  •    100MHz ~6G for RE
  • Frequency steps: 
  • 50kHz/500kHz step switchable for CE & RE with Monopole Antenna
  • 10MHz/100MHz step switchable for RE
  • Includes: Generator, antenna, charger, USB cable, wooden storage box

Data Sheet

SPECIFICATIONS

CG 50LR10100R, 50kHz/500kHz - 108MHz for LISN & 10MHz ~6GHz for RE, Comb Generator

Check out our Comb Generator Selection Guide.

Description

The CG 50LR10100R Comb Generators are reference signal sources for testing Line Impedance Stabilization Networks (LISN) and 30MHz-6GHz radiated emission measurements in EMI Chamber.  The CG50LR10100R output has the harmonics of the fundamental frequency specified by the step size. There are two bands included: from 50kHz ~ 108MHz with step sizes of 50kHz / 500kHz switchable, and 30MHz ~ 6GHz with step sizes of 10 MHz and 100MHz switchable.  This allows checks and investigations on conducted measurement systems to be made using a LISN, and RE measurements to be made in a EMI Chamber.

When fully charged, the battery allows continuous operation of up to 16 hours. The Comb Generator includes a battery charger, USB cable, and accessories. They are shipped in a wooden storage box.

Application

The main application of Comb Generator is to quickly verify conducted & radiated emissions test setups. The most important application is troubleshooting conducted measurements using a LISN and EMI radiated emissions in a chamber.

With the Comb Generator, the test engineer will be able to quickly perform a verification of the Conducted & Radiated test setup more frequently to assure accurate test results.

Other possible applications of the CG50LR10100R Comb Generator could include production evaluation of components such as cable shields and filters & Chamber validation according to CISPR16 & CISPR25 automotive standards.

 

Spesifications  
Frequency Range 500 kHz - 6 GHz
Frequency Step 50/500 kHz & 10/100MHz
Power Requirements USB mini,+5Vdc
Output connectors BNC
Charging time 8~10 Hours
Usage time 16 Hours
Size 120mm(W)*82mm(D)*85mm(H)
Net Weight  1.1Kg

 

Field Source Applications

  • normalized site attenuation measurements in fully anechoic rooms (FAR)
  • system checks for test labs (radiated emission)
  • shielding measurements
  • investigation of table and mast influence
  • laboratory inter-comparison measurements
  • test site correlation measurements (same type)
  • correlation of alternative test methods

Comb Generator Applications

  • system checks for test labs (radiated emission)
  • system checks for test labs (conducted emission)
  • “pseudo” EUTs
  • cable loss calibrations
  • normalized site attenuation measurements (SAC)
  • normalized site attenuation measurements (FAR)
  • laboratory inter-comparison measurements
  • test site correlation measurements (same type)
  • correlation of alternative test methods
  • chamber factor measurements
  • investigation of table and mast influence

 

 


 
OTHER PRODUCTS IN THE SAME CATEGORY: