CG 50/500LLA, 50 kHz - 30 MHz, 50 and 500 kHz Steps, Conducted Comb Generator

  • Frequency Range: 50 kHz - 30 MHz
  • Frequency step: 50 kHz or 500 kHz switchable
  • Usage time: up to 16 hrs.
  • Includes: Generator, loop antenna, charger, wood case

Data Sheet

SPECIFICATIONS

CG 50/500LLA, 50 kHz - 30 MHz, 50 and 500 kHz Steps, Conducted Comb Generator

Check out our Comb Generator Selection Guide.

Description

CG50/500LLA Comb Generator serves as reference signal source designed for testing Line Impedance Stabilization Networks (LISN). It generates harmonics aligned with the fundamental frequency within a frequency band ranging from 50kHz to 30MHz, with a switchable step size of 50kHz or 500kHz. This flexibility enables thorough checks and investigations on conducted measurement systems, facilitating usage with LISN and standard connectors for both conducted and radiated emission measurements in EMI Chambers. The battery, when fully charged, ensures continuous operation for up to 16 hours. Included with the Comb Generator are a battery charger, loop antenna, USB cable, and accessories packaged in a storage box.

Application

The main purpose of a Comb Generator is to efficiently validate setups for conducted & radiated emissions testing. Its primary application lies in troubleshooting conducted measurements using a LISN and EMI Radiation emission chamber.

With the Comb Generator, the test engineer can conduct frequent and rapid verifications of the conducted test setup, ensuring the reliability of test results.

Additional potential applications of the CG50/500LLA Conducted Comb Generator may involve the production evaluation of components, such as cable shields and filters.

Spesifications  
Frequency Range 50 kHz - 30 MHz
Frequency Step 50 & 500 kHz
Power Requirements USB mini,+5Vdc
Output connectors 50ohm N Female
Charging time 8~10 Hours
Usage time 16 Hours
Size 119mm(W)*81.5mm(D)*85.5mm(H)
Net Weight  1.0g

 

Field Source Applications

  • normalized site attenuation measurements in fully anechoic rooms (FAR)
  • system checks for test labs (radiated emission)
  • shielding measurements
  • investigation of table and mast influence
  • laboratory inter-comparison measurements
  • test site correlation measurements (same type)
  • correlation of alternative test methods

Comb Generator Applications

  • system checks for test labs (radiated emission)
  • system checks for test labs (conducted emission)
  • “pseudo” EUTs
  • cable loss calibrations
  • normalized site attenuation measurements (SAC)
  • normalized site attenuation measurements (FAR)
  • laboratory inter-comparison measurements
  • test site correlation measurements (same type)
  • correlation of alternative test methods
  • chamber factor measurements
  • investigation of table and mast influence

 

 


 
OTHER PRODUCTS IN THE SAME CATEGORY: