CG01-10, 10 MHz - 1 GHz, 10 MHz Steps, Comb Generator

  • Frequency Range: 10 MHz - 1 GHz
  • Frequency step: 10 MHz switchable
  • Includes: Generator, antenna, charger, wood case

Data Sheet

SPECIFICATIONS

CG01-10, 10 MHz - 1 GHz, 10 MHz Steps, Comb Generator

Check out our Comb Generator Selection Guide.

Features Description

The CG01 series Comb Generator is radiated reference signal source. As a conducted signal source, the output is available directly from the connector. An antenna is supplied with the CombGenerator for generating radiated reference signals. It is a self-contained source of signals consisting of frequency harmonics at 10 MHz intervals and is usable from 10MHz up to at least 1GHz.

The Comb Generator is powered by a rechargeable internal battery and external power cable connection. When fully charged, the battery allows continuous operation of up to 16 hours. The Comb Generator is included with a battery charger, USB cable, antennas, and accessories are shipped in a wooden storage box.

Application

The main application of Comb Generator is to quickly verify radiated emissions test setups. And the most important application is troubleshooting Open Area Test Sites(OATS) /chamber. An OATS must be completely calibrated before it is put into service.

With the Comb Generator, the test engineer will be able to perform quickly a verification of the conducted test setup more frequently to assure accurate test results. For example, any problem or change with the antenna, attenuator, or receiver will be reflected in the Comb Generator data with the same setup. The same method can be utilized when EMC emissions measurements for a product vary with sites. The Comb Generator can be used to determine if the test sites are causing the variation.

Other uses of the Comb Generator include evaluating shielding effectiveness or resonance performance of enclosures for electronic equipment.

Spesifications  
Frequency Range 10 MHz - 1 GHz
Frequency Step 10 MHz
Power Requirements USB mini,+5Vdc
Output connectors 50-ohm SMA Female
Charging time 8~10 Hours
Usage time 16 Hours
Size 120mm(W)*82mm(D)*85mm(H)
Net Weight  960g

 

Field Source Applications

  • normalized site attenuation measurements in fully anechoic rooms (FAR)
  • system checks for test labs (radiated emission)
  • shielding measurements
  • investigation of table and mast influence
  • laboratory inter-comparison measurements
  • test site correlation measurements (same type)
  • correlation of alternative test methods

Comb Generator Applications

  • system checks for test labs (radiated emission)
  • system checks for test labs (conducted emission)
  • “pseudo” EUTs
  • cable loss calibrations
  • normalized site attenuation measurements (SAC)
  • normalized site attenuation measurements (FAR)
  • laboratory inter-comparison measurements
  • test site correlation measurements (same type)
  • correlation of alternative test methods
  • chamber factor measurements
  • investigation of table and mast influence

 

 


 
OTHER PRODUCTS IN THE SAME CATEGORY:
Loading...