CCK20 Calibration kit for: PG 10-200, PG 12-360 and PG 20-100

The Capacitor Calibration Kit CCK has been designed to measure the pulse output voltage of surge generators PG10-200, PG12-360 and PG20-100.

PARTNER:

MARKETS:

TEST STANDARDS:

Data Sheet

SPECIFICATIONS

CAPACITOR CALIBRATION KIT 

 

CCK20

 

 

 

? Capacitor Calibration Kit
? Input voltage: 20kV
? 50nF, 50nF, 33nF, 23nF
 

 The Capacitor Calibration Kit CCK has been designed to measure the pulse output voltage of surge generators PG10-200, PG12-360 and PG20-100.

 

 Operation:


The network input is directly connected to the HV output of the surge generator.

 

The "GND" connection to the network is connected in this constellation on the HV connector and can additional be connected to the grounding screw on the generator.

 

To achieve the best results, the cable should be kept as short as possible.

 

 

The different capacities can be switched between 23nF and 156nF. Parallel connection of the individual capacitors by jumpers produced a total capacity value of 156nF. Other capacitance values (23, 33. 50, 73, 100, 156nF) from the four basic capacities are possible.

 

 

Technical specification

CCK 20

 

Input voltage, wave form 1,2/50 µs

20 kV max.

 

Input capacitance Line 1

50 nF

Input capacitance Line 2

50 nF

Input capacitance Line 3

33 nF

Input capacitance Line 4

23 nF

 

Tolerance

± 3%

 

 

 

 

 

 

 