CDG 7000-200 Conducted Immunity, 4 kHz - 400MHz, 200Watts

CDG 7000-200 Conducted Immunity, 4 kHz - 400MHz, 200Watts

CDG 7000 Conducted Immunity, (4)10 kHz - 400MHz

CDG 7000 Conducted Immunity, (4)10 kHz - 400MHz

CDG 7000-E Conducted Immunity Generator, (4)9 kHz - 1 GHz , No internal Amplifier

CDG 7000-E Conducted Immunity Generator, (4)9 kHz - 1 GHz , No internal Amplifier

CDG 7000-75-10 Magnetic Immunity, 10 kHz - 400MHz, IEC 61000-4-39

CDG 7000-75-10 Magnetic Immunity, 10 kHz - 400MHz, IEC 61000-4-39

CDG CDN Coupling / Decoupling Networks

CDG CDN Coupling / Decoupling Networks

CDG EMCL- NW 10 / MN-1 EM Clamp Matching Network

CDG EMCL- NW 10 / MN-1 EM Clamp Matching Network

CDG CDN EMCL-20 / CDG CDN EMCL-35 EM Clamp

CDG CDN EMCL-20 / CDG CDN EMCL-35 EM Clamp

CDG CDN ABCL-20 Decoupling Clamp

CDG CDN ABCL-20 Decoupling Clamp

CDG CDN ABCL-35 Decoupling Clamp

CDG CDN ABCL-35 Decoupling Clamp

CDG CDN BCI-P1 Bulk Current Injection Probe 1 MHz – 400 MHz

CDG CDN BCI-P1 Bulk Current Injection Probe 1 MHz – 400 MHz

CDG CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz

CDG CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz

CDG CMP-45 Current Monitoring Probe, Foldable, with Calibration Set

CDG CMP-45 Current Monitoring Probe, Foldable, with Calibration Set

Products

CDG 7000-200 Conducted Immunity, 4 kHz - 400MHz, 200Watts

  • Generator frequency range CDG 7000-200 covers 100 kHz – 400 MHz, 
  • CDG 7000-200 supports BCI testing up to 500 mA closed loop with the appropriate accessories
  • Optional CDG 7000-200-4 amplifier extends the CDG 7000-200 system downward to 4 kHz – 1 MHz
  • EUT monitoring, SCPI control of other equipment

CDG 7000 Conducted Immunity, (4)10 kHz - 400MHz

  • Integrated RF signal generator, RF power amplifier, 3-channel RF voltmeter, and directional coupler
  • Generator frequency range from 9 kHz to 1.2 GHz, usable from 4 kHz
  • RF amplifier configurations available from 25 W to 200 W
  • Frequency coverage options from 10 kHz to 400 MHz, depending on model
  • HELIA 7-Basic software included for test control, reporting, and EUT monitoring
  • External amplifier expansion through the second generator output
  • SCPI command set for integration into automated EMC software systems

CDG 7000-E Conducted Immunity Generator, (4)9 kHz - 1 GHz , No internal Amplifier

The CDG 7000-E is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields - including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. Use an external Amplifier you already have or one that matches your application. 

  • The compact device comprises an RF signal generator, a 3-channel RF voltmeter, and a directional coupler.
  • Frequency range of the generator/power meter (4 kHz): 9 kHz – 1200 MHz
  • The frequency range of the directional coupler: 10 kHz – 1000 MHz, 200 W 
  • Depending on ext. amplifier:  IEC/EN 61000-4-6, IEC 60601-1-2 Ed. 4.1,  IEC 61000-4-39, MIL 461 CS 114, ISO 11452-4, ...

CDG 7000-75-10 Magnetic Immunity, 10 kHz - 400MHz, IEC 61000-4-39

The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields - including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. IEC 60601-1-2 calling out IEC 61000-4-39 magnetic immunity for close proximity testing requirements can also now be met with the 10 kHz unit. 

CDG CDN Coupling / Decoupling Networks

The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields - including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price.

CDG EMCL- NW 10 / MN-1 EM Clamp Matching Network

EMCL- NW 10 / MN-1 Matching Network • For use with the EMCL-20 in the frequency range 10 kHz – 150 kHz • For use with the CDN BCI-P1 in the frequency range 10 kHz – 150 kHz

CDG CDN EMCL-20 / CDG CDN EMCL-35 EM Clamp

EM Clamp for immunity tests IEC / EN 61000-4-6 Ed. 4.0 • EM Clamp for immunity testing of cables with up to 20 (35) mm diameter • High coupling factor: less than 15 watts amplifier output power is required to obtain a test level of 10 V • Calibration unit and calibration data are supplied with each unit.

CDG CDN ABCL-20 Decoupling Clamp

CDN ABCL-20 Decoupling Clamp for immunity according to IEC / EN 61000-4-6 Ed. 4.0 100 kHz – 1000 MHz Features: For additional decoupling at immunity testing according to IEC / EN 61000-4-6 Suitable for cables up to 20mm diameter

CDG CDN ABCL-35 Decoupling Clamp

CDN ABCL-35 Decoupling Clamp for immunity according to IEC / EN 61000-4-6 Ed. 4.0 100 kHz – 1000 MHz Features: For additional decoupling at immunity testing according to IEC / EN 61000-4-6 Suitable for cables up to 20mm diameter

CDG CDN BCI-P1 Bulk Current Injection Probe 1 MHz – 400 MHz

BCI-P1 Bulk Current Injection Probe 10 kHz – 400 MHz - Meets specifications of ISO 11452-4:2005 and IEC 61000-4-6 - Frequency range from 1 MHz up to 400 MHz - Designed for automotive BCI testing - Low insertion loss (1MHz - 400MHz) to test bellow 1MHz (IEC/DO/MIL) see CDN BCI-P1_MT-1

CDG CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz

CDG CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz - Meets specifications of ISO 11452-4:2005, MIL-STD-461, DO-160 and IEC 61000-4-6 - Frequency range from 4 kHz up to 400 MHz - Designed for BCI testing 

CDG CMP-45 Current Monitoring Probe, Foldable, with Calibration Set

CDG CMP-45 Current monitoring probe • Cable diameters up to 45 mm • Frequency range 10 kHz to 400 MHz • Foldable, easy positioning on the conductor / cable • For BCI testing acc. to ISO 11452-4 and others • Insertion impedance < 2,5 ?