AB-Precompliant Test Kits

AB-Precompliant Test Kits

EMScanner: 150 kHz- 8 GHz, 3.5mm Resolution,  EMC desktop scanner

EMScanner: 150 kHz- 8 GHz, 3.5mm Resolution, EMC desktop scanner

EMScannerR: 150 kHz- 8 GHz, 0.06mm resolution, EMC desktop scanner

EMScannerR: 150 kHz- 8 GHz, 0.06mm resolution, EMC desktop scanner

EMProbe: 9kHz- 18 GHz, 0.2mm resolution, EMC robotic scanner

EMProbe: 9kHz- 18 GHz, 0.2mm resolution, EMC robotic scanner

EM Near Field Probe Kit w/Camera & Software

EM Near Field Probe Kit w/Camera & Software

TBPS01 EMC NEAR-FIELD PROBES + TBWA2/40dB WIDEBAND AMPLIFIER

TBPS01 EMC NEAR-FIELD PROBES + TBWA2/40dB WIDEBAND AMPLIFIER

TBPS01 EMC NEAR-FIELD PROBES + TBWA2/20dB WIDEBAND AMPLIFIER

TBPS01 EMC NEAR-FIELD PROBES + TBWA2/20dB WIDEBAND AMPLIFIER

TBCAS1 Coaxial Adapter Set

TBCAS1 Coaxial Adapter Set

TBPS01 EMC NEAR-FIELD PROBES

TBPS01 EMC NEAR-FIELD PROBES

TBMR-110M DC - 110 MHz high speed EMI-Analyzer

TBMR-110M DC - 110 MHz high speed EMI-Analyzer

TBLC08 - 50uH Line Impedance Stabilization Network LISN CISPR 16

TBLC08 - 50uH Line Impedance Stabilization Network LISN CISPR 16

TBOH01 - 5µH Line Impedance Stabilization Network CISPR 25

TBOH01 - 5µH Line Impedance Stabilization Network CISPR 25

Products

AB-Precompliant Test Kits

Absolute EMC has designed low-cost pre-compliance systems to meet a wide range of RF emissions and immunity needs. Some form of pre-complaint testing is a must for any company that needs to demonstrate their product for EMC compliance.  This enables companies to be responsive when issues happen and to also be proactive before going to the lab to better your chances of passing the first time. 

EMScanner: 150 kHz- 8 GHz, 3.5mm Resolution, EMC desktop scanner

  • Capability:
    • Spectral scan, spatial scan, peak-hold, continuous scanning, spectral and spatial comparison, scripting, limit lines, and report generation.
  • Spatial scan time:
    • Continuous real-time or sub-second single scan for the entire scan area is dependent on spectrum analyzer performance.
  • Spectral scan time:
    • 45 seconds for L 10 cm x W 10 cm (L 4” x W 4”) PCB with a 100 MHz span and 100 kHz RBW. Scanning area, span, and RBW are user-selectable within spectrum analyzer specifications
  • EMViewer Software
    • We recommend you use the EMViewer software for best results.  A Yearly subscription or a once-off purchase is available. 
  • Supported operating systems: Windows 10®
  • Supported CAD overlays: Standard Gerber© RS274x format and HPGL format

EMScannerR: 150 kHz- 8 GHz, 0.06mm resolution, EMC desktop scanner

  • Capability:
    • Spectral scan, spatial scan, peak-hold, continuous scanning, spectral and spatial comparison, scripting, limit lines, report generation, and notes.
  • Spatial scan time:
    • Continuous real-time for the entire scan area (1,218 probes activated) when Level 1 is selected:  5 sec.
    • Selected area 2.25 cm x 2.25 cm, 9 probes activated.
    • Level 1: 
  • Spectral scan time:
    • 11 seconds for L 10 cm x W 10 cm (L 4” x W 4”, 178 probes activated) from 10 MHz span to 110 MHz and 122 kHz RBW. Scanning area, span, and RBW are user-selectable within spectrum analyzer specifications
  • Supported operating systems: Windows 10®
  • Supported overlays: Picture in JPEG format 
  • Standard Gerber© RS274x format and HPGL form

EMProbe: 9kHz- 18 GHz, 0.2mm resolution, EMC robotic scanner

  • Capability:
    • Spectral scan, spatial scan, peak-hold, continuous scanning, spectral and spatial comparison, scripting, limit lines, report generation, and notes.
    • Customization of the robot arm size, any size, is possible. 
  • Spatial scan time:
    • The scan time depends on size and area
  • Ideal for large component boards
    • The robotic arm allows for advanced scans on complex items
  • Supported operating systems: Windows 10®
  • Supported overlays: Picture in JPEG format 
  • Standard Gerber© RS274x format and HPGL form

EM Near Field Probe Kit w/Camera & Software

" A Probe Kit on Steroids"

  • Fully integrated with Y.I.C. Technologies EMViewer software and EMProbe
  • Normalization and correction when using the EMViewer software
  • Flat response within the range of operation
  • Slim Design and Protective Coating
  • 18GHz Measured Cable included

TBPS01 EMC NEAR-FIELD PROBES + TBWA2/40dB WIDEBAND AMPLIFIER

The H20, H10, H5, and E5 are magnetic field (H) and electric field (E) probes for radiated emissions EMC pre-compliance measurements. The probes are used in the near field of sources of electromagnetic radiation. They serve to locate and identify potential sources of interference within the building blocks of electronic assemblies. The probes act similar to wide bandwidth antennas, picking up radiated emissions from components, PCB traces, housing openings or gaps and from any other parts that could be emitting RF. The probes are usually connected to a spectrum analyzer. Scanning the probe over the surface of a PCB assembly or housing quickly identifies locations which emit electromagnetic radiation. By changing to a probe with a smaller size, the origination of the emissions can be further narrowed down. With TBWA2 WIDEBAND AMPLIFIER/40DB

TBPS01 EMC NEAR-FIELD PROBES + TBWA2/20dB WIDEBAND AMPLIFIER

The H20, H10, H5, and E5 are magnetic field (H) and electric field (E) probes for radiated emissions EMC pre-compliance measurements. The probes are used in the near field of sources of electromagnetic radiation. They serve to locate and identify potential sources of interference within the building blocks of electronic assemblies. The probes act similar to wide bandwidth antennas, picking up radiated emissions from components, PCB traces, housing openings or gaps and from any other parts that could be emitting RF. The probes are usually connected to a spectrum analyzer. Scanning the probe over the surface of a PCB assembly or housing quickly identifies locations which emit electromagnetic radiation. By changing to a probe with a smaller size, the origination of the emissions can be further narrowed down. With TBWA2 WIDEBAND AMPLIFIER/20DB

TBCAS1 Coaxial Adapter Set

The TBCAS1 coaxial adapter set contains 44 pieces of the most common 50 Ohm coaxial adapters in a beechwood box

TBPS01 EMC NEAR-FIELD PROBES

The H20, H10, H5, and E5 are magnetic field (H) and electric field (E) probes for radiated emissions EMC pre-compliance measurements. The probes are used in the near field of sources of electromagnetic radiation. They serve to locate and identify potential sources of interference within the building blocks of electronic assemblies. The probes act similar to wide bandwidth antennas, picking up radiated emissions from components, PCB traces, housing openings or gaps, and from any other parts that could be emitting RF. The probes are usually connected to a spectrum analyzer. Scanning the probe over the surface of a PCB assembly or housing quickly identifies locations that emit electromagnetic radiation. By changing to a probe with a smaller size, the origination of the emissions can be further narrowed down. 

TBMR-110M DC - 110 MHz high speed EMI-Analyzer

The TBMR-110M EMI Analyzer is designed to carry out conducted emission measurements. Its affordability and versatility make it a perfect tool for engineers doing pre-compliance measurements during the development process.
  • True DC – 110 MHz measurement range
  • CISPR-16, ANSI and MIL-STD compliant detectors
  • Peak, Quasi-Peak, Average, CISPR Average, RMS and CISPR RMS dectectors working in parallel
  • Zero Span operation with time domain triggering
  • Linear, log amplitude and frequency display

TBLC08 - 50uH Line Impedance Stabilization Network LISN CISPR 16

The TBLC08 is a Line Impedance Stabilization Network for the measurement of line-conducted interference within the range of 9kHz to 30MHz, according to the CISPR16 standard. The device is designed for testing single phase, AC-powered equipment with supply voltages up to maximum 240V.

TBOH01 - 5µH Line Impedance Stabilization Network CISPR 25

The TBOH01 5µH LISN is a device required to setup conducted noise measurements of DC-powered devices. It is designed to be used for EMC pre-testing in the frequency range of 150kHz to 110 MHz.

Loading...