FIS 100-200 Fast Interrupt Switch 100V/200Amps

FIS 100-200 Fast Interrupt Switch 100V/200Amps

400 - 6112, 2-Ch, 250kS/s, AnyWave Control Unit

400 - 6112, 2-Ch, 250kS/s, AnyWave Control Unit

400 - 6361, 2-Ch, 2.8MS/s, AnyWave Control Unit

400 - 6361, 2-Ch, 2.8MS/s, AnyWave Control Unit

100-TS, 4-Quadrant Voltage Amplifiers 400 W - 54,000 W

100-TS, 4-Quadrant Voltage Amplifiers 400 W - 54,000 W

100-TS, 4-Quadrant Current Amplifiers 400 W - 54,000 W

100-TS, 4-Quadrant Current Amplifiers 400 W - 54,000 W

100-TS, VW 80000 / LV 124 : Battery test systems Test systems for 12 V | 24 V | 48 V batteries

100-TS, VW 80000 / LV 124 : Battery test systems Test systems for 12 V | 24 V | 48 V batteries

100-TS, VW 80300 / LV 123 / LV 148 : HV Electric vehicle test systems

100-TS, VW 80300 / LV 123 / LV 148 : HV Electric vehicle test systems

ONYX 16, 16kV ESD Simulator

ONYX 16, 16kV ESD Simulator

ONYX 30, 30kV ESD Simulator

ONYX 30, 30kV ESD Simulator

Axos 5 - Compact 5kV EFT, Surge, Dips/Drops

Axos 5 - Compact 5kV EFT, Surge, Dips/Drops

Axos 8 - Compact 7kV Surge, Telecom, Ring Wave, 5kV EFT, Dips/Drops

Axos 8 - Compact 7kV Surge, Telecom, Ring Wave, 5kV EFT, Dips/Drops

MAG 1000, 120A/m CW, 1100Am Short Duration, Power Frequency Magnetic Field

MAG 1000, 120A/m CW, 1100Am Short Duration, Power Frequency Magnetic Field

Products

FIS 100-200 Fast Interrupt Switch 100V/200Amps

  • High current power stage (uni-directional)
  • Up to 32 channels for switching low-current signals (bi-directional)
  • Switching of resistive, inductive, capacitive passive, and active loads/devices
  • Input voltage up to 100V
  • Output current up to 200A DC

400 - 6112, 2-Ch, 250kS/s, AnyWave Control Unit

WaveMaster + AnyWave

BOLAB WaveMaster software and the BOLAB AnyWave control unit allow the control of power supplies as well as 4 quadrant amplifiers via the analog interfaces.

The powerful and easy-to-use BOLAB WaveMaster software is unique in the world. Without any knowledge in software development, designing ordinary and complex waveforms is very easy. A graphic waveform editor allows the generation

of individual curves in no time. Also, with tabular input, all types of waveforms can be produced instantly.

400 - 6361, 2-Ch, 2.8MS/s, AnyWave Control Unit

WaveMaster + AnyWave

BOLAB WaveMaster software and the BOLAB AnyWave control unit allow the control of power supplies as well as 4 quadrant amplifiers via the analog interfaces.

The powerful and easy-to-use BOLAB WaveMaster software is unique in the world. Without any knowledge in software development, designing ordinary and complex waveforms is very easy. A graphic waveform editor allows the generation

of individual curves in no time. Also, with tabular input, all types of waveforms can be produced instantly.

100-TS, 4-Quadrant Voltage Amplifiers 400 W - 54,000 W

  • DC - 200 kHz bandwidth DC 
  • MHz (small signal -3 dB)
  • Output voltage ±75 Vpk
  • Rise / fall time 100 V/µs
  • USB interface standard, LAN optional
  • Analog control input 0 ... ±10 V for control of voltage and current
  • Monitor outputs for measured voltage and current values (not all models)
  • Modularly extensible via master-slave mode
  • Parallel and Series Connections for two or more units

100-TS, 4-Quadrant Current Amplifiers 400 W - 54,000 W

  • DC - 200 kHz bandwidth DC 
  • MHz (small signal -3 dB)
  • Output voltage ±75 Vpk
  • Rise / fall time 100 V/µs
  • USB interface standard, LAN optional
  • Analog control input 0 ... ±10 V for control of voltage and current
  • Monitor outputs for measured voltage and current values (not all models)
  • Modularly extensible via master-slave mode
  • Parallel and Series Connections for two or more units

100-TS, VW 80000 / LV 124 : Battery test systems Test systems for 12 V | 24 V | 48 V batteries

  • Protocol reports
  • Generation of waveforms with synchronous data acquisition 
  • Modular Expandable
  • Individual Waveform Generation
  • Standard Libraries included
  • Unlimited Waveform size
  • 2 different Waveforms synchronously 
  • DLL's for LabView, Vector CANoe / CAPL, C#, C++, ANSI C, Python, etc.
  • Simulation of imported oscilloscope waveform

100-TS, VW 80300 / LV 123 / LV 148 : HV Electric vehicle test systems

BOLAB´s new and world´s unique solutions in testing High Voltage profiles for Electric Vehicles are very powerful, flexible, and modular.

Three different solutions for high-speed testing, a medium-range for covering most profiles, and a low budget. Powerful solutions for starting and gaining experience are available.

Modularity is one of the most important characteristics of BOLAB´s systems.

Start with a “small” system of 1 KW (1.000 V, 15 A) and expand module by module as applications require and budgets allow.

It was never this easy to get involved with high voltage tests for Electric Vehicles and to build up these tests to a most powerful solution.

ONYX 16, 16kV ESD Simulator

Onyx 16

  • +/- 16kV air and Contact Discharge
  • 150pF/330Ohm Standard, Other networks available
  • >16 hour Battery life, AC mains option
  • Optional Software

ONYX 30, 30kV ESD Simulator

Onyx 30

  • +/- 30kV air and Contact Discharge
  • 150pF/330Ohm Standard, Other networks available
  • >16 hour Battery life, AC mains option
  • Optional Software

Axos 5 - Compact 5kV EFT, Surge, Dips/Drops

Axos 5 - Compact

  • Multi Tester with 16AMP CDN
  • EFT/Burst 5kV IEC 61000-4-4
  • Surge, Combination Wave 5kV IEC 61000-4-5
  • Surge Magnetic field IEC 61000-4-9 (MSURGE-A loop antenna required)
  • AC Dips/Drops IEC 61000-4-11 (DIP 116 dips transformer required)
  • DC Dips/Drops IEC 61000-4-29 (2x DC supplies required)

Axos 8 - Compact 7kV Surge, Telecom, Ring Wave, 5kV EFT, Dips/Drops

Axos 8 - Compact

  • Multi Tester with 16AMP CDN
  • EFT/Burst 5kV IEC 61000-4-4
  • Surge, Combination Wave 7kV IEC 61000-4-5
  • Surge Magnetic field IEC 61000-4-9 (MSURGE-A loop antenna required)
  • Ring Wave, 7kV IEC 61000-4-12 & ANSI
  • Telicomm Wave, 7kV IEC 61000-4-5 & ITU
  • AC Dips/Drops IEC 61000-4-11 (DIP 116 dips transformer required)
  • DC Dips/Drops IEC 61000-4-29 (2x DC supplies required)

MAG 1000, 120A/m CW, 1100Am Short Duration, Power Frequency Magnetic Field

MAG 1000

  • 1-120A/m Contiunus testing
  • 100-1100A/m Short Duration 1-3sec
  • Test either 50Hz & 60Hz Selectable
  • 1m square Loop

Loading...