The Vertical Coupling Plate (VCP) is used in conjunction with ESD generators to simulate indirect discharges on metallic objects that are near a test object. The bleeder resistors contained in the ground wire of the VCP serve to prevent the applied charge from vanishing immediately after the discharge of the ESD generator to the VCP, thereby increasing the effect of the ESD test.
PARTNER:
MARKETS:
TEST STANDARDS:
SESD 271
· Vertical Coupling Plate (VCP) for ESD immunity tests
The Vertical Coupling Plate (VCP) is used in conjunction with ESD generators to simulate indirect discharges on metallic objects that are near a test object. The bleeder resistors contained in the ground wire of the VCP serve to prevent the applied charge from vanishing immediately after the discharge of the ESD generator to the VCP, thereby increasing the effect of the ESD test.
Technical specifications |
|
VCP |
|
Dimensions: Material: |
50 x 50 cm aluminum, 1.5mm thickness |
Ground wire |
|
Color: Length: Connections: Bleeder resistors: Outer diameter: Voltage max: |
Black 2 m Cable connectors Ø 6.2 mm 2x 470 KΩ approx. 3.5mm for ESD pulses according to IEC / EN 61000-4-2 up to 30 kV |