PPG-E1-1200, PCI Short pulse (E1) generator, 1.2kA

PPG-E1-1200 Portable Pulse Generator – Key Highlights

  • MIL-STD-188-125 Compliant – Designed for HEMP Pulse Current Injection (PCI) testing.
  • High-Current Pulse Generation – Delivers 50 A to 1.2 kA short-circuit current.
  • Battery-Powered for Field Testing – Operates >24 hours without external power.
  • Fast & Efficient Testing – Pulse rise time ≤ 20 ns, pulse duration 500-550 ns.
  • USB Fiber Optic Control – Remote operation with full galvanic isolation for safety.
  • Complete Test System Available – Includes couplers, current probes, decoupling networks.
  • Rugged Transport Case – Portable & easy to deploy for on-site testing.
  • Industry-Leading Accuracy – Precise data acquisition & error-free pulse measurement.

MARKETS:

TEST STANDARDS:

Data Sheet

System Description PCI Tests

SPECIFICATIONS

PPG-E1-1200 Portable Pulse Generator

MIL-STD-188-125 Short Pulse E1 Testing for HEMP Protection

Absolute EMC is the exclusive North American sales partner for Montena Technology’s PPG-E1-1200 Portable Pulse Generator, designed for testing protective devices against High-Altitude Electromagnetic Pulse (HEMP) at electrical entry points of fixed ground-based facilities and transportable systems. This generator meets the requirements of MIL-STD-188-125-1 and -2 (PCI: Pulse Current Injection), ensuring compliance and reliability in high-impact environments.

Typical Test Setup

The PPG-E1-1200 delivers a high-current pulse either directly or through coupling devices to test the effectiveness of protective devices at electrical entry points. A residual pulse enters the protected facility, which is monitored using current probes connected via fiber optics to an oscilloscope inside a shielded enclosure.


Key Features & Capabilities

MIL-STD-188-125 Compliance

  • Generates high-current short pulses for Pulse Current Injection (PCI) testing.
  • Supports direct or coupled pulse injection into protective devices.

High-Performance Pulse Generator

  • Peak Current: 50 A to 1.2 kA (short circuit).
  • Peak Voltage: 3 kV to 80 kV (open circuit).
  • Output Waveform: Double-exponential.
  • Pulse Rise Time: ≤ 20 ns.
  • Pulse Duration (FWHM): 500 – 550 ns.
  • Source Impedance: ≥ 60 Ω.

Portable & Battery-Powered for On-Site Testing

  • The self-contained system operates independently of external power sources.
  • Over 24 hours of battery life, ensuring extended field operation.
  • Ruggedized transport case on wheels for easy deployment.

Safe & Efficient Operation

  • USB-controlled over fiber optic for full galvanic isolation of the operator.

Comprehensive Testing Setup

  • Current probes, capacitive and inductive couplers, and decoupling networks are available.
  • Broadband fiber optic links for accurate pulse measurement.
  • Dedicated control software for precise system configuration and data recording.

Technical Specifications

ParameterSpecification
Standard Compliance MIL-STD-188-125-1 and -2 / Short Pulse (E1)
Peak Current (Short Circuit) 50 A – 1.2 kA
Peak Voltage (Open Circuit) 3 kV – 80 kV
Pulse Rise Time (Short Circuit) ≤ 20 ns
Pulse Length (FWHM, Short Circuit) 500 – 550 ns
Charging Time < 15 s
Output Interface 8m HV coaxial cable with termination resistor
Insulation Oil-insulated
Control Interface USB over fiber optic
Power Options 110-130V or 220-240V, 50/60 Hz
Battery Autonomy > 24 hours
Battery Charging Time 3 h (0-80%), 4h30 (0-100%)
Safety Compliance EN61010-1, interlock + safety switch
Operating Temperature 0 to +45°C
Storage Temperature -10 to +60°C
Generator Dimensions 55 x 50 x 25 cm
Transport Case Dimensions 85 x 72 x 45 cm
Weight (Generator + Cable) 37 kg
Total Weight (With Case & Accessories) 62 kg

Complete Testing System & Accessories

Ordering Information

ModelDescription 
PPG-E1-1200 Portable pulse generator for MIL-STD-188-125, pulse rise-time < 20 ns, 50 – 1200 A.  
PULSELab PULSELab software: The system is delivered with PULSELab, montena pulse measurement software application.  

Optional Accessories

ModelDescription 
CC-E1-1200-1 Single-output capacitive/varistor coupler for MIL-STD-188-125. (showing both single and 4 line)
CC-E1-1200-4 Four-output capacitive/varistor coupler for MIL-STD-188-125.
IC-E1-1200 Inductive coupler, 40 mm internal diameter, max 1200 A, 1:1 ratio.
IC-E1-2150 Special inductive coupler, 40 mm internal diameter, max 2150 A, 1:2 ratio.
DL3 2-line decoupling device, max 60A, screw connectors.
TLB4 Dummy load resistor box (0.2, 0.5, 2.0, 50 ohm), banana + screw connectors.
MOL2000T Optical transmitter & receiver module, 50Ω, 80 Hz – 3.5 GHz, remote gain.
FO2C50 Dual fiber optic cable, 50 m with cable reel.
SB3G Shielded enclosure (61 x 52 x 73 cm) for oscilloscope & accessories.
Shielded Tent  
Shielded Control Room  

 

Why Choose Absolute EMC for Your HEMP Testing Needs?

  • Exclusive North American Partner of Montena Technology.
  • Industry-leading HEMP & MIL-STD-188-125 compliance solutions.
  • Portable, battery-powered generator for field and on-site testing.
  • Complete test system available with accessories & fiber optic monitoring.
  • Expert consultation, support, and after-sales service.

Order Now

Ensure your facility meets MIL-STD-188-125 compliance with the PPG-E1-1200 and its full range of accessories. Contact Absolute EMC for a quote, lead times, and consultation.

OTHER PRODUCTS IN THE SAME CATEGORY:
Loading...