The safety test cabinets PA 50* are designed for high-voltage testing of components and PCB's etc.
PA 502/ 503/ 504/ 505/ 400
The safety test cabinets PA 50* are designed for high-voltage testing of components and PCB etc. The transparent cabinets prevent accidental contact with live parts of the test object yet allow observation of the test object during testing.
Upon lifting of the cover, the safety interlock loop of the high-voltage generator is interrupted and the generator is switched off, the test object and the generator's energy storage capacitor is discharged.
|
Options |
PA 50* |
|
|
Impulse voltage divider |
built-in |
Max. input voltage, 1.2/50 µs |
12/24 kV |
Ratio |
1000:1 ± 2 % |
|
|
High-voltage output connector system |
built-in |
HV-cable with plugs |
1.0 m long |
|
|
Electronic safety relay with contactless test cabinet switch. |
built-in |
Technical specifications |
PA 503 |
PA 505 |
PA 502 |
PA504 |
|
||||
Figure |
|
|
|
|
Max. input voltage |
12/24 kV |
12/24 kV |
12/24 kV |
12/24 kV |
High-voltage output connector |
4 mm Æ |
4 mm Æ |
4 mm Æ |
4 mm Æ |
HV-cable |
1.0 m lang |
1.0 m lang |
1.0 m lang |
1.0 m lang |
Protective ground terminal, screw |
M 6 |
M 6 |
M 6 |
M 6 |
Safety interlock connector |
Break contact, 24V-dc |
Break contact, 24V-dc |
Break contact, 24V-dc |
Break contact, 24V-dc |
Safety interlock interconnection cable |
1.0 m long |
1.0 m long |
1.0 m long |
1.0 m long |
Red and green warning lights acc. to VDE 0104 |
24 V=, 40 mA |
24 V=, 40 mA |
24 V=, 40 mA |
24 V=, 40 mA |
Interconnection cable |
1.0 m long |
1.0 m long |
1.0 m long |
1.0 m long |
Dimensions W * H * D |
470 * 220 * 490 mm³ |
470 * 320 * 490 mm³ |
490 * 260 * 480 mm³ |
555 * 480 * 600 mm³ |
Test space W * H * D |
400 * 140 * 300 mm³ |
400 * 250 * 400 mm³ |
440 * 180 * 300 mm³ |
460 * 300 * 550 mm³ |
Weight |
10 kg |
10 kg |
10 kg |
10 kg |
|
|