The EFTC-CK is a calibration kit for burst/EFT coupling clamps as specified in IEC 6100-4-4:2012. It has been designed for calibration of coupling clamps like EFTC2012. The set consists of a transducer plate and a termination bracket (connecting adapter).

Data Sheet

SPECIFICATIONS

EFTC-CK

Calibration kit for burst coupling clamps (EFTC2012) Transducer plate with connecting adapter

 

 

 

 

According to

IEC 61000-4-4 : 2012

 

 

 

The EFTC-CK is a calibration kit for burst/EFT coupling clamps as specified in IEC 6100-4- 4:2012. It has been designed for calibration of coupling clamps like EFTC2012.

The set consists of a transducer plate and a termination bracket (connecting adapter).

The calibration kit EFTC-CK is to be used together with a 50W termination kit, which is included in the delivery of BCK400F, and an oscilloscope with a bandwidth >400MHz.

 

 

 

Usage:

 

The coupling clamp EFTC2012 is connected to the direct output of a burst generator. The transducer plate is inserted into the coupling clamp and a 50W terminator is connected to its output. A test voltage of 2000V is output at the burst generator and the following parameters must be detected on the connected oscilloscope:

 

Rise time:

5ns ± 1,5ns

Pulse duration:

50ns ± 15ns

Peak voltage:

1000V ± 200V

 

  

 

 

TECHNICAL SPECIFICATIONS:

EFTC-CK

Material

Aluminum, conductive

Dimensions

120mm x 1050mm

Thickness

0,5mm

Isolation

Dielectric foil with a thickness of 0,5mm, all around

Isolation voltage

Min. 2,5kV – on all sides

Connection for 50 W

Fischer HV-bush

Other contacts (BNC/ SHV) on request

Total length, set

1085mm (with adapter)

Weight

720g

Ambient temperature

0 – 40 ° Celsius

Relative humidity

0 – 60 %