The EFTC-CK is a calibration kit for burst/EFT coupling clamps as specified in IEC 6100-4-4:2012. It has been designed for calibration of coupling clamps like EFTC2012. The set consists of a transducer plate and a termination bracket (connecting adapter).
PARTNER:
MARKETS:
TEST STANDARDS:
|
According to |
IEC 61000-4-4 : 2012 |
|
The EFTC-CK is a calibration kit for burst/EFT coupling clamps as specified in IEC 6100-4- 4:2012. It has been designed for calibration of coupling clamps like EFTC2012. The set consists of a transducer plate and a termination bracket (connecting adapter). The calibration kit EFTC-CK is to be used together with a 50W termination kit, which is included in the delivery of BCK400F, and an oscilloscope with a bandwidth >400MHz. |
|
The coupling clamp EFTC2012 is connected to the direct output of a burst generator. The transducer plate is inserted into the coupling clamp and a 50W terminator is connected to its output. A test voltage of 2000V is output at the burst generator and the following parameters must be detected on the connected oscilloscope: |
Rise time: |
5ns ± 1,5ns |
Pulse duration: |
50ns ± 15ns |
Peak voltage: |
1000V ± 200V |
TECHNICAL SPECIFICATIONS: |
EFTC-CK |
Material |
Aluminum, conductive |
Dimensions |
120mm x 1050mm |
Thickness |
0,5mm |
Isolation |
Dielectric foil with a thickness of 0,5mm, all around |
Isolation voltage |
Min. 2,5kV – on all sides |
Connection for 50 W |
Fischer HV-bush Other contacts (BNC/ SHV) on request |
Total length, set |
1085mm (with adapter) |
Weight |
720g |
Ambient temperature |
0 – 40 ° Celsius |
Relative humidity |
0 – 60 % |