BOLAB ISO 21498 HV Test System & Ripple Generator

BOLAB ISO 21498 HV Test System & Ripple Generator

FIS 100-200 Fast Interrupt Switch 100V/200Amps

FIS 100-200 Fast Interrupt Switch 100V/200Amps

400 - 6112, 2-Ch, 250kS/s, AnyWave Control Unit

400 - 6112, 2-Ch, 250kS/s, AnyWave Control Unit

ONYX 16, 16kV ESD Simulator

ONYX 16, 16kV ESD Simulator

400 - 6361, 2-Ch, 2.8MS/s, AnyWave Control Unit

400 - 6361, 2-Ch, 2.8MS/s, AnyWave Control Unit

BOLAB ISO 7637-4 HV Test System

BOLAB ISO 7637-4 HV Test System

BLS 100-TS, For Low Voltage ISO 7637-2 & 16750-2 Transient testing

BLS 100-TS, For Low Voltage ISO 7637-2 & 16750-2 Transient testing

BOLAB ISO 16750-2 Test System

BOLAB ISO 16750-2 Test System

ONYX 30, 30kV ESD Simulator

ONYX 30, 30kV ESD Simulator

100-TS, 4-Quadrant Voltage Amplifiers 400 W - 54,000 W

100-TS, 4-Quadrant Voltage Amplifiers 400 W - 54,000 W

BLS SU 600, Matrix Switching Unit

BLS SU 600, Matrix Switching Unit

100-TS, 4-Quadrant Current Amplifiers 400 W - 54,000 W

100-TS, 4-Quadrant Current Amplifiers 400 W - 54,000 W

Products

BOLAB ISO 21498 HV Test System & Ripple Generator

  • Advanced Ripple Testing: Meets ISO 21498, LV123, VW 80300, Nissan MES PW 67602, Mazda, and emerging standards.
  • Series Amplifier Integration: High accuracy ripple injection, minimal distortion, and enhanced safety.
  • Waveform Versatility: Sine, square, trapezoidal, pulses, and triangle waveform generation.
  • WaveMaster Software: Fast DUT impedance measurement, automated test sequences, and dynamic voltage/current control.
  • High Power Capability: Ripple Voltage up to 100 Vpp, currents from 100A to 2000A+, and frequency range 10 Hz–300+ kHz.
  • Future-Proof Design: Modular architecture for easy upgrades and adaptation to new standards.

FIS 100-200 Fast Interrupt Switch 100V/200Amps

  • High current power stage (uni-directional)
  • Up to 32 channels for switching low-current signals (bi-directional)
  • Switching of resistive, inductive, capacitive passive, and active loads/devices
  • Input voltage up to 100V
  • Output current up to 200A DC

400 - 6112, 2-Ch, 250kS/s, AnyWave Control Unit

WaveMaster + AnyWave

BOLAB WaveMaster software and the BOLAB AnyWave control unit allow the control of power supplies as well as 4 quadrant amplifiers via the analog interfaces.

The powerful and easy-to-use BOLAB WaveMaster software is unique in the world. Without any knowledge in software development, designing ordinary and complex waveforms is very easy. A graphic waveform editor allows the generation

of individual curves in no time. Also, with tabular input, all types of waveforms can be produced instantly.

ONYX 16, 16kV ESD Simulator

Onyx 16

  • +/- 16kV air and Contact Discharge
  • 150pF/330Ohm Standard, Other networks available
  • >16 hour Battery life, AC mains option
  • Optional Software

400 - 6361, 2-Ch, 2.8MS/s, AnyWave Control Unit

WaveMaster + AnyWave

BOLAB WaveMaster software and the BOLAB AnyWave control unit allow the control of power supplies as well as 4 quadrant amplifiers via the analog interfaces.

The powerful and easy-to-use BOLAB WaveMaster software is unique in the world. Without any knowledge in software development, designing ordinary and complex waveforms is very easy. A graphic waveform editor allows the generation

of individual curves in no time. Also, with tabular input, all types of waveforms can be produced instantly.

BOLAB ISO 7637-4 HV Test System

  • Full Compliance – Meets all ISO 7637-4 test requirements
  • Pulse A Testing – Simulates MOSFET/IGBT switching noise (100 kHz – 10 MHz)
  • Pulse B Testing – Low-frequency sinusoidal disturbances (3 kHz – 300 kHz)
  • High-Power RF Amplifier75W output (100 kHz – 400 MHz) for clean signal generation
  • Burst Generator – Supports configurable burst parameters (1–1000 cycles)
  • Power Meter & Directional Coupler – Accurate transient measurement (100 kHz – 10 MHz)
  • Integrated Transformer – Isolates high-voltage circuits & prevents transient damage
  • Scalable & Modular – Configurable for custom DUT testing needs
  • Turnkey Solution – Includes generator, amplifier, coupler, and switching solutions

BLS 100-TS, For Low Voltage ISO 7637-2 & 16750-2 Transient testing

  • Protocol reports
  • Generation of waveforms with synchronous data acquisition 
  • Modular Expandable
  • Individual Waveform Generation
  • Standard Libraries included
  • Unlimited Waveform size
  • 2 different Waveforms synchronously 
  • DLL's for LabView, Vector CANoe / CAPL, C#, C++, ANSI C, Python, etc.
  • Simulation of imported oscilloscope waveform

BOLAB ISO 16750-2 Test System

  • DUT Current Ratings: 40A, 76A, 114A, 152A, 190A, 228A
  • Voltage Ripple: Up to 200 kHz (500 kHz)
  • Amplifier: BOLAB 100-TS Series 4-quadrant system
  • Load Dump Generator: BOLAB 10/63-210 1C
  • Switching: FIS 100-xx & FIS SM 96-2 (expandable)
  • Power Supply: BOLAB or third-party compatible
  • High-Voltage & Insulation Testing: G1-1G-T & 90-4K
  • Modular & Scalable: Full ISO 16750-2:2023 compliance

ONYX 30, 30kV ESD Simulator

Onyx 30

  • +/- 30kV air and Contact Discharge
  • 150pF/330Ohm Standard, Other networks available
  • >16 hour Battery life, AC mains option
  • Optional Software

100-TS, 4-Quadrant Voltage Amplifiers 400 W - 54,000 W

  • DC - 200 kHz bandwidth DC 
  • MHz (small signal -3 dB)
  • Output voltage ±75 Vpk
  • Rise / fall time 100 V/µs
  • USB interface standard, LAN optional
  • Analog control input 0 ... ±10 V for control of voltage and current
  • Monitor outputs for measured voltage and current values (not all models)
  • Modularly extensible via master-slave mode
  • Parallel and Series Connections for two or more units

BLS SU 600, Matrix Switching Unit

  • Protocol reports
  • Generation of waveforms with synchronous data acquisition 
  • Modular Expandable
  • Individual Waveform Generation
  • Standard Libraries included
  • Unlimited Waveform size
  • 2 different Waveforms synchronously 
  • DLL's for LabView, Vector CANoe / CAPL, C#, C++, ANSI C, Python, etc.
  • Simulation of imported oscilloscope waveform

100-TS, 4-Quadrant Current Amplifiers 400 W - 54,000 W

  • DC - 200 kHz bandwidth DC 
  • MHz (small signal -3 dB)
  • Output voltage ±75 Vpk
  • Rise / fall time 100 V/µs
  • USB interface standard, LAN optional
  • Analog control input 0 ... ±10 V for control of voltage and current
  • Monitor outputs for measured voltage and current values (not all models)
  • Modularly extensible via master-slave mode
  • Parallel and Series Connections for two or more units

Loading...