MDS 21 C, 30 - 1000 MHz, EMI Absorbing Clamp

MDS 21 C, 30 - 1000 MHz, EMI Absorbing Clamp

CMAD 1614, 10 - 1000 MHz, Common Mode Absorption Device

CMAD 1614, 10 - 1000 MHz, Common Mode Absorption Device

EMCL 6146, 10 - 1000 MHz, EM Coupling Clamp and CAL EMCL Cal Fixture

EMCL 6146, 10 - 1000 MHz, EM Coupling Clamp and CAL EMCL Cal Fixture

FTC 101 C Decoupling Clamp

FTC 101 C Decoupling Clamp

CAL CMAD 1614, Calibration fixture for CMAD 1614

CAL CMAD 1614, Calibration fixture for CMAD 1614

CVP 9222 C, 9 kHz - 100 MHz, High Impedance Capacitive Voltage Probe

CVP 9222 C, 9 kHz - 100 MHz, High Impedance Capacitive Voltage Probe

SW 9602, 10 kHz - 200 MHz  Current Transformer

SW 9602, 10 kHz - 200 MHz Current Transformer

SW 9603, 9 kHz - 150 MHz  Current Transformer

SW 9603, 9 kHz - 150 MHz Current Transformer

SW 9605, 9 kHz - 80 MHz  Current Clamp

SW 9605, 9 kHz - 80 MHz Current Clamp

SW 9606, 9 kHz - 200 MHz  Current Clamp

SW 9606, 9 kHz - 200 MHz Current Clamp

CA 9608, DC - 500 MHz  Universal Calibration Jig for Current Clamps

CA 9608, DC - 500 MHz Universal Calibration Jig for Current Clamps

CF 9651 Current Clamp Calibration Fixture

CF 9651 Current Clamp Calibration Fixture

Products

MDS 21 C, 30 - 1000 MHz, EMI Absorbing Clamp

  • EMI Absorbing Clamp
  • 30 - 1000 MHz
  • acc. CISPR 16 for interference power with silicon-coated rolls
  • Also for shielding measurements on coax. cables

CMAD 1614, 10 - 1000 MHz, Common Mode Absorption Device

  • Common-Mode Absorbing Clamp
  • (10) 30 - 200 (1000)MHz
  • Suppress unwanted common mode currents
  • Cable bundles maximum diameter of 26 mm
  • acc. CISPR 16-1-4

EMCL 6146, 10 - 1000 MHz, EM Coupling Clamp and CAL EMCL Cal Fixture

  • Common-Mode Absorbing Clamp
  • Usable frequency range: 10kHz - 1000MHz
  • Meets EN / IEC 61000-4-6
  • Cable bundles maximum diameter of 25 mm
  • Optional Cal Fixture: CAL EMCL

FTC 101 C Decoupling Clamp

Decoupling Clamp

Improve decoupling between the injection clamp and auxiliary equipment.

The FTC 101 C is a ferrite decoupling clamp for conducted immunity setups using the EMCL 6146 RF-injection clamp. It increases isolation toward auxiliary equipment (AE) in IEC/EN 61000-4-6 testing while accommodating cables up to 25 mm in diameter.

CAL CMAD 1614, Calibration fixture for CMAD 1614

  • Calibration fixture for Common-Mode Absorbing Clamp
  • (10) 30 - 200 (1000)MHz

CVP 9222 C, 9 kHz - 100 MHz, High Impedance Capacitive Voltage Probe

  • Calibration fixture for Common-Mode Absorbing Clamp
  • (10) 30 - 200 (1000)MHz

SW 9602, 10 kHz - 200 MHz Current Transformer

  • Current Transformer
  • Shielded
  • 0.01 - 200 MHz
  • Transfer Impedance: 1 Ohm for wires up to 6.5 mm

SW 9603, 9 kHz - 150 MHz Current Transformer

  • Current Transformer
  • Shielded
  • 0.09 - 150 MHz
  • Transfer Impedance: 1 Ohm for wires up to 14 mm

SW 9605, 9 kHz - 80 MHz Current Clamp

  • Clamp-on Current Clamp
  • 0.09 - 80 MHz
  • Transfer Impedance: 1 Ohm for wires up to 23 mm

SW 9606, 9 kHz - 200 MHz Current Clamp

  • Clamp-on Current Clamp
  • 0.09 - 200 MHz
  • Transfer Impedance: 8 Ohm for wires up to 23 mm

CA 9608, DC - 500 MHz Universal Calibration Jig for Current Clamps

  • Clamp-on Current Clamp
  • 0.09 - 200 MHz
  • Transfer Impedance: 8 Ohm for wires up to 23 mm

CF 9651 Current Clamp Calibration Fixture

Current Clamp Calibration Fixture

A defined fixture for repeatable current-clamp measurements.

The CF 9651 supports transfer-impedance and insertion-impedance measurements of SW 9600 Bx and SW 9601 Ax current clamps, plus other probes with comparable dimensions. Its aluminum enclosure and centered conductor provide a repeatable mechanical arrangement.