HFRA 5164, 10 kHz - 120 MHz Transmitting loop antenna

HFRA 5164, 10 kHz - 120 MHz Transmitting loop antenna

FESP 5139 - DISCONTINUED replaced by HFRA 5164

FESP 5139 - DISCONTINUED replaced by HFRA 5164

FESP 5133-9 - 10 kHz - 3 MHz Radiating Loop

FESP 5133-9 - 10 kHz - 3 MHz Radiating Loop

FESP 5132 - DC - 150 kHz Radiating Loop

FESP 5132 - DC - 150 kHz Radiating Loop

FESP 5133 - DC - 200 kHz Radiating Loop

FESP 5133 - DC - 200 kHz Radiating Loop

FESP 5133-1330 - DC - 50 kHz Radiating Loop

FESP 5133-1330 - DC - 50 kHz Radiating Loop

FESP 5135 - DC - 300 kHz Radiating Loop

FESP 5135 - DC - 300 kHz Radiating Loop

FESP 5133-360, 10 - 160 kHz Field Monitoring Coil

FESP 5133-360, 10 - 160 kHz Field Monitoring Coil

HFRA SF02G - 0.01 - 30 MHz Transmitting Tunable loop antenna

HFRA SF02G - 0.01 - 30 MHz Transmitting Tunable loop antenna

FESP 5133-7/41 - 10 - 250 kHz Circular Screened Coil

FESP 5133-7/41 - 10 - 250 kHz Circular Screened Coil

FESP 5134-40 - 5 -250 kHz Circular Screened Coil

FESP 5134-40 - 5 -250 kHz Circular Screened Coil

FESP 5134-1 - 10 - 400 MHz Circular Screened Coil

FESP 5134-1 - 10 - 400 MHz Circular Screened Coil

Products

HFRA 5164, 10 kHz - 120 MHz Transmitting loop antenna

  • The circular transmitting loop antenna
  • 0.01 - 120 MHz
  • diam. 100 mm
  • turns 3
  • BNC Connectors 

FESP 5139 - DISCONTINUED replaced by HFRA 5164

  • After further development of this antenna, it has been discovered a shielded antenna is needed to be useful above 5MHz
  • New HFRA 5164 is 100% compliant to IEC 61000-4-39

FESP 5133-9 - 10 kHz - 3 MHz Radiating Loop

  • Magnetic, handheld coil
  • 10 kHz - 3 MHz
  • diam. 133 mm
  • turns 9
  • Immunity testing to VG 95377 Part 13

FESP 5132 - DC - 150 kHz Radiating Loop

  • Magnetic, handheld coil
  • DC - 150 kHz
  • diam. 120 mm
  • turns 20
  • Immunity testing to: ISO 11452-8, MIL 461E RS101, EN 55103 5.18.3.2, IEC 61000-4-39

FESP 5133 - DC - 200 kHz Radiating Loop

  • Magnetic, handheld coil
  • DC - 200 kHz
  • diam. 133 mm
  • turns 36
  • Immunity testing to MIL 461, EN 55103 - 2 A.2.1 b), EN 55103 - 2 A.4.1

FESP 5133-1330 - DC - 50 kHz Radiating Loop

  • Magnetic, handheld coil
  • DC - 50 kHz
  • diam. 126 mm
  • turns 225
  • Immunity testing to Measuring Method SF 01 G acc. to VG 95377

FESP 5135 - DC - 300 kHz Radiating Loop

  • Magnetic, handheld coil
  • DC - 300 kHz
  • diam. 500 mm
  • turns 20
  • Immunity testing to EN 55103 - 2 A.3.1

FESP 5133-360, 10 - 160 kHz Field Monitoring Coil

  • Magnetic field monitoring loop 
  • 10 - 160 kHz
  • Diam. 133mm
  • turns 360
  • Emissions testing

HFRA SF02G - 0.01 - 30 MHz Transmitting Tunable loop antenna

  • 10 kHz to 30 MHz
  • acc. to VG95373-13:2008-11 and VG95373-23:2008-11. Including sensor loop HFRAE 5163 and control cable.
  • diam. 500 mm
  • 2 Turn
  • 16 Watts

FESP 5133-7/41 - 10 - 250 kHz Circular Screened Coil

  • Magnetic field monitoring loop 
  • 10 - 250 kHz
  • Diam. 133mm
  • turns 36
  • Emissions testing

FESP 5134-40 - 5 -250 kHz Circular Screened Coil

  • Magnetic field monitoring loop 
  • 5 - 250 kHz
  • Diam. 40mm
  • turns 51
  • The level setting for Immunity testing to MIL-STD-461
  • Meets requirements of Stellantis CS.00244 2023 ELECTRICAL AND EMC PERFORMANCE REQUIREMENTS FOR E/E COMPONENTS

FESP 5134-1 - 10 - 400 MHz Circular Screened Coil

  • Magnetic field monitoring loop 
  • 10 - 400 MHz
  • Diam. 40mm
  • turns 1
  • Level setting for Immunity testing to IEC 61000-4-39