5 µH 50 A Configurable LISN
TBL0550-1C Single-path network for conducted emissions and line termination in aviation and defense test setups. It uses an N-female measurement output and protected M8 power terminals.
| Characterized frequency range | 10 kHz–400 MHz |
|---|---|
| Continuous current | 50 A continuous |
| Operating voltage by supply frequency | 480 V AC at 50/60 Hz, 360 V AC at 400 Hz, 230 V AC at 800 Hz or 1,200 V DC |
| RF output | N-female RF output |
| Power terminals | M8 power terminals |
| Dimensions | 125 × 125 × 275 mm |
| Weight | 1.75 kg |
RTCA DO-160 and DEF-STAN-59 applications.
Use the frequency-specific voltage limit when selecting a model. A pair can be used with a LISN Mate for common-mode and differential-mode diagnosis.
TBL0550-1B Single-path network for conducted emissions and line termination. The factory 50 Ω ? (5 µH + 1 Ω) configuration can be changed to 50 Ω ? 5 µH using an internal jumper.