HI 200, 1m x 1m Magnetic Immunity Coil for use with HILO/TEST

Power frequency magnetic fields acc. to IEC 61000-4-8 Test levels continuous 3 / 10 / 30 / 100 / 300 A/m. Test level 1000 A/m short, with a special transformer. Pulsed magnetic fields acc. to IEC 61000-4-9 Test levels 100 / 300 / 1000 A/m

Data Sheet

SPECIFICATIONS

 HI 200

 

Helmholtz Coil

 

   

 

 

According to

IEC 61000-4-8

IEC 61000-4-9

 

 

 

 

You can position the Hi 200 coil in vertical in a horizontal position to your test object and fix it with lamps or brace supports.

 

 

 

Air coil designed for Generation of:

 

·      Power frequency magnetic fields acc. to IEC 61000-4-8 Test levels continuous 3 / 10 / 30 / 100 / 300 A/m

 

  •  Test level 1000 A/m short, with special transformer

 

 

·      Pulsed magnetic fields acc. to IEC 61000-4-9 Test levels 100 / 300 / 1000 A/m           

 

  •  Wave shape 8/20µs

 

  

 

Technical Specification

HI 200

Dimensions

1000*1000 mm

Type of Coil

Standard Coil

Coil factor

H/I » 0.9 /m

max. 50/60 Hz magnetic field strength acc. to IEC 61000-4-8

300 A/m

max. pulsed magnetic field strength acc. to IEC 61000-4-9

1000 A/m

Transformer Output

Floating, not connected to PE

Special Transformer

HI 200 - 1000

Dimensions

300*300

Short time use

1-3s

max. 50/60 Hz magnetic field strength acc. to IEC 61000-4-8

1000 A/m

 

 

OTHER PRODUCTS IN THE SAME CATEGORY: