CP 9610 - DC - 1 MHz Galvanically Isolated Current SensorThe current sensor CP 9610 can measure up to 40 A in a frequency range from DC – 1 MHz. It is galvanically isolated and can withstand a maximum voltage of 210 VPK / VDC. The internal resistance of the conductive path is less than 3 mOhm, providing low power loss. The hall transducer is temperature compensated and allows high accuracy over temperature. To adjust the output voltage to zero, ensure that the probe is disconnected from current-carrying conductors. The offset can be adjusted with the potentiometer “ZERO ADJUST” by using a suitable screwdriver. The nominal conversion factor is 50 mV / A. The range of measurement is ± 40 A. The output voltage is proportional to the current and is up to ± 2 V. Current probe to monitor the current through radiating loop or Helmholtz coils. It can be used to measure currents in case a shunt is not allowed (Ford EMC-CS- 2009), including 1m RG223/U BNC-BNC. Specifications:
Delivery accessories
|