High-current source for power-frequency magnetic field immunity testing according to IEC 61000-4-8, -4-9, and -4-10.
The MFPO 9760 is a high-power current transformer designed to drive the FESP 5410-1 1 m square induction coil at the typical mains frequencies of 50/60 Hz. Together, they form a robust solution for generating strong, well-defined magnetic fields for EMC immunity testing in accordance with industrial power-frequency and surge/impulse magnetic field standards.
When used with the FESP 5410-1, the MFPO 9760 can produce short-term fields above 1000 A/m and continuous fields up to 360 A/m at the coil center, making it suitable for demanding qualification of power electronics, industrial controllers, traction/rail systems, and other sensitive equipment.
High-current magnetic field source
Drives the FESP 5410-1 coil with currents up to 1200 A (≤ 5 s), 600 A (≤ 5 min) and 400 A continuous, enabling test levels required by IEC 61000-4-8/-4-9/-4-10.
Power-frequency and pulsed operation
Optimized for 50/60 Hz operation; the low-inductance, single-turn coil allows fast transitions and pulsed or oscillatory magnetic field waveforms for surge/impulse testing.
Integrated pulse generator
Built-in timing electronics provide adjustable ON intervals from approximately 0.5 s to 5 s.
Longer or custom intervals can be set manually by holding the start button or via a remote control input.
High field strength capability
With FESP 5410-1, achieves > 1000 A/m (short-time) and 360 A/m continuous at the coil center, covering and exceeding typical industrial test levels.
Optimized for IEC magnetic field immunity standards
Designed specifically for tests according to IEC 61000-4-8, IEC 61000-4-9, and IEC 61000-4-10 (and aligned national standards such as GB/T 17626.8).
Robust, lab-grade construction
Heavy-duty cabinet with high-current buswork and proper thermal design for continuous operation at rated levels.
Designed for long-term use in EMC test labs and certification environments.
Power-frequency magnetic field immunity testing per IEC 61000-4-8
Pulsed or transient magnetic field immunity per IEC 61000-4-9
Oscillatory magnetic field tests per IEC 61000-4-10
Evaluation of industrial control systems, power converters, UPS systems, and switchgear
Testing of sensitive instrumentation, protection relays, and safety systems exposed to strong mains-related magnetic fields
A typical MFPO 9760 system includes:
MFPO 9760 Current Transformer and Pulse Generator
FESP 5410-1 1 m Square Induction Coil for generating the magnetic field at the EUT
Appropriate high-current cabling and mounting hardware (coil on non-conductive mast or support structure)
Two FESP 5410-1 coils can be combined as a Helmholtz pair to increase field strength and improve field uniformity over a larger test volume, particularly for bulky EUTs or multi-cabinet systems.
| Parameter | Value | Notes |
|---|---|---|
| Power requirement | 230 V AC, 50/60 Hz, 16 A | Single-phase mains supply |
| Max. continuous current into coil | 400 A | Continuous operation |
| Max. current (5 min) | 600 A | Limited-time operation (thermal constraint) |
| Max. current (≤ 5 s) | 1200 A | Short-time pulses/surge tests |
| Max. field strength (coil center, ≤ 5 s) | > 1000 A/m | With FESP 5410-1, at coil center |
| Max. continuous field strength | 360 A/m | At coil center with 400 A continuous |
| Compatible coil | FESP 5410-1, 1 m square coil | 1-turn, low-inductance magnetic field coil |
| Coil characteristics (FESP 5410-1) | 0.9 A/m per 1 A coil current; 1 m side; 1 turn | DC…10 MHz frequency range |
| ON-time setting (internal pulse generator) | ~0.5 s to 5 s | Adjustable via front panel; longer via manual or remote control |
| Dimensions (W × D × H) | approx. 650 × 800 × 490 mm | Cabinet only |
| Weight | approx. 60 kg | |
| Output connector to coil | M16 male threads | Compatible with FESP 5410-1 |
| Applicable standards | IEC 61000-4-8, IEC 61000-4-9, IEC 61000-4-10 | Industrial frequency & surge magnetic immunity |