NFCN 9732-85, 80 - 90 kHz Compensation Network for HHS 5206-8

  • Compensation Network
  • For HHS 5206-8
  • up to 11 Arms
  • 80 - 90 kHz (85 kHz)

MARKETS:

TEST STANDARDS:

Data Sheet

SPECIFICATIONS

 

NFCN 9732-85, 80 - 90 kHz (85 kHz) Compensation Network for HHS 5206-8

The compensation network NFCN 9732 85 kHz consists of a high current/ high voltage variable capacitor.  The compensation capacitor reduces the total impedance of the series circuitry consisting of the Helmholtz coil HHS 5206-8 and the NFCN 9732 85 kHz at the operating frequency band of 80-90 kHz. It allows continuous currents of up to 15 Arms at generator voltages of less than 40 Vrms. You can choose from 11 different capacitance values with a rotary switch in 1 kHz steps from 80 kHz to 90 kHz. When using test frequencies that are between the given frequencies use a position that is closest to the needed frequency. A capacitance of 15.7 nF is hard wired to the 4 mm safety laboratory connectors. The variable capacitor part gets added to the total capacitance value by using relays

 

 Specifications:     

  Max continuous current:

 

  • 15 A Max (50% Duty Cycle) 
  • up to 11 Arms Continus

 

  Dimensions:  105 mm x 105 mm x 360 mm
  Capacitance range:  15.65 - 19.42 nF
  Frequency range:  80 - 90 kHz
     
  Weight:  2.1 kg

 

  

 

 

  

 

 

  