The capacitive Coupling-/Decoupling Network CDN 2802 is used in combination with the Multi-CE5 & Multi-CE7 and allows superimposition of surge and burst test pulses to up to eight I/O signal lines.
PARTNER:
MARKETS:
TEST STANDARDS:
CDN 2802
Main |
8* 48 V= / 2 A= |
Surge |
2.0 kV, 1.2/50 µs |
Burst |
2.0 kV, 5/50 ns |
According to |
IEC 61000-4-4 |
IEC 61000-4-5 |
IEEE 587 |
The capacitive Coupling-/Decoupling Network CDN 2802 is used in combination with the Multi-CE and allows superimposition of surge and burst test pulses to up to eight I/O signal lines.
The test set-up is suitable for surge immunity testing of electronic systems and devices according to IEC 61000-4-4:2012, IEC 61000-4-5:2014 and IEEE 587.
The coupling-/decoupling impedance of CDN 2802 can be switched to:
· for surge impulse: 0.1µF / 0.5µF + 40 W / 500 W, decoupling inductance 20 mH. Optionally can be installed for 0.1 µF a Varistor 48V
· for burst impulse: 33 nF, decoupling inductance 100 µH.
Coupling mode can be selected from the front panel of the Multi-CE. Remote control commands are transmitted from the Multi-CE to the Coupling-/Decoupling Network by use of a data cable.
Technical specification: |
CDN 2802 |
Nominal voltage |
8 * 48 V= |
Nominal current AC/DC |
2 A= |
max. test voltage Surge, 1.2/50 µs: |
2.0 kV |
max. test voltage Burst, 5/50 ns: |
2.0 kV |
Coupling impedance for the surge generator |
0.1 µF / 0.5 µF + 40 W / 500 W |
Coupling impedance for the burst generator |
33 nF |
|
|
Coupling mode, selectable, for the surge generator |
line to line via 0.1/0.5 µF line to ground via 0.1/0.5 µF |
Coupling mode, selectable, for the burst generator |
line to ground via 33nF |
|
|
Burst Input |
Fischer |
Surge Input |
4 mm Bush |
|
|
Mains power |
90V - 264 V, 50/60 Hz |
Dimensions: desktop case W * H * D |
450*180*500 mm3 |
Weight |
20 kg |