CLP40K, 400 A, Charge line generator, POE

  • MIL-STD-188-125-2 Compliant – Designed for pulse current injection (PCI) testing of antenna POE protective devices.
  • Adjustable High-Voltage Pulses0.2 - 25 kV, 400A (CLP40K) for precise testing.
  • Broad Frequency Coverage – Supports testing from 30 MHz up to 477.5 MHz with variable charge line plugs.
  • Ultra-Fast Pulse Rise Time and for high-speed transient testing.
  • Direct Coaxial Coupling – No external coupling device required for efficient pulse injection.
  • Automated Operation & Remote ControlRS232 & USB interfaces for seamless integration and monitoring.
  • Complete Test Solution – Includes charge line plugs, current probes, fiber optic links, and optional Montena PULSELab software.

MARKETS:

TEST STANDARDS:

System Description PCI Tests

Data Sheet

SPECIFICATIONS

CLP40K, 400 A, Charge line generator for Point of Entry (PoE)

 

High-Voltage Pulse Testing for Antenna Point of Entry Protection

The PCI - Charge Line Pulse Generator is engineered to evaluate the performance of antenna point of entry (POE) protective devices in accordance with MIL-STD-188-125-2 and similar standards. This system ensures precise pulse current injection (PCI) testing, allowing for accurate assessment of EMC shielding and EMP protection.

Available in two models—the CLP40K and CLP5K—this charge line generator delivers adjustable high-voltage pulses with variable frequency selection, providing a versatile and user-friendly solution for aerospace, military, and telecommunications testing.

Typical Test Setup

The IPP3K-4MS delivers a high-current pulse either directly or through coupling devices to test the effectiveness of protective devices at electrical entry points. A residual pulse enters the protected facility, which is monitored using current probes connected via fiber optics to an oscilloscope inside a shielded enclosure.

 

Figure: typical verification test setup with the IPP3K-4MS generator

  


Key Features & Capabilities

  • MIL-STD-188-125-2 Compliant – Ensures accurate charge line pulse injection for protective device validation.
  • High-Voltage Capability – Adjustable 0.2 - 25 kV (CLP40K) and 0.05 - 5 kV (CLP5K) voltage ranges.
  • Broad Frequency Coverage – Supports testing from 30 MHz up to 477.5 MHz with variable charge line plugs.
  • Precision Pulse Generation – Delivers fast rise times ( with controlled energy output.
  • Multi-Frequency Testing – Includes 10 or 11 charge line plugs to generate predefined quarter-wavelength pulses.
  • Direct Coaxial Coupling – No additional coupling device needed; pulses are directly injected into the coaxial cable or POE protective device.
  • Automated & Remote Control – Fully programmable via RS232 & USB interfaces for seamless integration.

System Configurations & Technical Specifications

CLP40K - High Voltage Charge Line Generator

Designed for high-voltage pulse testing, covering 30 MHz to 250 MHz.

SpecificationCLP40K
Charging Voltage 0.2 - 25 kV (Positive Only)
Peak Short Circuit Current ≥ 400 A (30 MHz Charge Line Plug)
Source Impedance 50 Ohm
Pulse Rise Time < 5 ns
Charging Time < 30 sec
Charge Line Test Frequencies 30, 40, 50, 75, 100, 125, 150, 175, 220, ~250 MHz
Output Connectors 2 x HVM50K (Montena Proprietary)
Triggering Manual or Remote
Control Interface RS232 & USB
Power Rating 85 - 264 V / 50 - 60 Hz / 150 VA
Dimensions (Control Unit) 56 x 19 x 45 cm (L x H x W)
Weight (Control Unit) 15.1 kg
Dimensions (HV Module) 30 x 12 x 20 cm (L x H x W)
Weight (HV Module) 3.2 kg

Complete Test Setup & Accessories

  • Charge Line Pulse Test Setup – Used for coaxial protective device validation with pulse currents up to 400 A.
  • Charge Line PlugsPredefined quarter-wavelength connectors ensure precise pulse generation at specific frequencies.
  • Montena PULSELab Software – Automates control, data acquisition, and real-time waveform analysis.
  • Current Probes & Adapters – Optional accessories for advanced waveform monitoring and measurement.
  • Fiber Optic Links – Provides electrical isolation for remote control and safety.

 

Ordering Information

ModelDescription 
CLP40K Charge Line generator, 0.2 - 25 kV, 30 to 250 MHz, 10 test frequencies  
PULSELab PULSELab software: The system is delivered with PULSELab, montena pulse measurement software application.  

Optional Accessories

ModelDescription 
MOL2000T Optical transmitter & receiver module, 50Ω, 80 Hz – 3.5 GHz, remote gain.
FO2C50 Dual fiber optic cable, 50 m with cable reel.
SB3G Shielded enclosure (61 x 52 x 73 cm) for oscilloscope & accessories.
Shielded Tent  
Shielded Control Room  

 Why Choose the CLP40K & CLP5K for Charge Line Pulse Testing?

  • MIL-STD-188-125-2 Compliant – Industry-proven solution for POE protection device validation.
  • Fast & Reliable TestingHigh-voltage, high-frequency pulses with repeatable precision.
  • Wide Frequency RangeTwo models available, covering 30 MHz to 477.5 MHz.
  • Automated & Remote OperationRS232 & USB interfaces for full control and data acquisition.
  • Designed for Direct Coaxial Connection – Eliminates the need for additional coupling devices.

Order Now

Ensure your facility meets MIL-STD-188-125 compliance with the CLP40K and its full range of accessories. Contact Absolute EMC for a quote, lead times, and consultation.

OTHER PRODUCTS IN THE SAME CATEGORY:
Loading...