CLP40K, 400 A, Charge line generator for Point of Entry (PoE)
High-Voltage Pulse Testing for Antenna Point of Entry Protection
The PCI - Charge Line Pulse Generator is engineered to evaluate the performance of antenna point of entry (POE) protective devices in accordance with MIL-STD-188-125-2 and similar standards. This system ensures precise pulse current injection (PCI) testing, allowing for accurate assessment of EMC shielding and EMP protection.
Available in two models—the CLP40K and CLP5K—this charge line generator delivers adjustable high-voltage pulses with variable frequency selection, providing a versatile and user-friendly solution for aerospace, military, and telecommunications testing.
Typical Test Setup
The IPP3K-4MS delivers a high-current pulse either directly or through coupling devices to test the effectiveness of protective devices at electrical entry points. A residual pulse enters the protected facility, which is monitored using current probes connected via fiber optics to an oscilloscope inside a shielded enclosure.
Figure: typical verification test setup with the IPP3K-4MS generator
Key Features & Capabilities
MIL-STD-188-125-2 Compliant – Ensures accurate charge line pulse injection for protective device validation.
High-Voltage Capability – Adjustable 0.2 - 25 kV (CLP40K) and 0.05 - 5 kV (CLP5K) voltage ranges.
Broad Frequency Coverage – Supports testing from 30 MHz up to 477.5 MHz with variable charge line plugs.
Precision Pulse Generation – Delivers fast rise times ( with controlled energy output.
Multi-Frequency Testing – Includes 10 or 11 charge line plugs to generate predefined quarter-wavelength pulses.
Direct Coaxial Coupling – No additional coupling device needed; pulses are directly injected into the coaxial cable or POE protective device.
Automated & Remote Control – Fully programmable via RS232 & USB interfaces for seamless integration.
System Configurations & Technical Specifications
CLP40K - High Voltage Charge Line Generator
Designed for high-voltage pulse testing, covering 30 MHz to 250 MHz.
Specification
CLP40K
Charging Voltage
0.2 - 25 kV (Positive Only)
Peak Short Circuit Current
≥ 400 A (30 MHz Charge Line Plug)
Source Impedance
50 Ohm
Pulse Rise Time
< 5 ns
Charging Time
< 30 sec
Charge Line Test Frequencies
30, 40, 50, 75, 100, 125, 150, 175, 220, ~250 MHz
Output Connectors
2 x HVM50K (Montena Proprietary)
Triggering
Manual or Remote
Control Interface
RS232 & USB
Power Rating
85 - 264 V / 50 - 60 Hz / 150 VA
Dimensions (Control Unit)
56 x 19 x 45 cm (L x H x W)
Weight (Control Unit)
15.1 kg
Dimensions (HV Module)
30 x 12 x 20 cm (L x H x W)
Weight (HV Module)
3.2 kg
Complete Test Setup & Accessories
Charge Line Pulse Test Setup – Used for coaxial protective device validation with pulse currents up to 400 A.
Charge Line Plugs – Predefined quarter-wavelength connectors ensure precise pulse generation at specific frequencies.
Montena PULSELab Software – Automates control, data acquisition, and real-time waveform analysis.
Current Probes & Adapters – Optional accessories for advanced waveform monitoring and measurement.
Fiber Optic Links – Provides electrical isolation for remote control and safety.
Ordering Information
Model
Description
CLP40K
Charge Line generator, 0.2 - 25 kV, 30 to 250 MHz, 10 test frequencies
PULSELab
PULSELab software: The system is delivered with PULSELab, montena pulse measurement software application.
Shielded enclosure (61 x 52 x 73 cm) for oscilloscope & accessories.
Shielded Tent
Shielded Control Room
Why Choose the CLP40K & CLP5K for Charge Line Pulse Testing?
MIL-STD-188-125-2 Compliant – Industry-proven solution for POE protection device validation.
Fast & Reliable Testing – High-voltage, high-frequency pulses with repeatable precision.
Wide Frequency Range – Two models available, covering 30 MHz to 477.5 MHz.
Automated & Remote Operation – RS232 & USB interfaces for full control and data acquisition.
Designed for Direct Coaxial Connection – Eliminates the need for additional coupling devices.
Order Now
Ensure your facility meets MIL-STD-188-125 compliance with the CLP40K and its full range of accessories. Contact Absolute EMC for a quote, lead times, and consultation.
OTHER PRODUCTS IN THE SAME CATEGORY:
TS-CS114-CS115-CS116 TurnKey Test System for MIL-STD-461 CS114, CS115, CS116
PG1275F - MIL-STD-1275F Surge/Spike Test Generator
POG-CS116 - CS116 Test Generator, Dampened Wave
PGESD 300K DP - Helicopter 300kV ESD Test System
ONYX 16, 16kV ESD Simulator
ONYX 30, 30kV ESD Simulator
PG-CS115 - CS115 Test Generator, 1kV into 50 Ohms
NEMP-WM - Chamber Wall Mount RS105 Test System >50kV/m
NEMP050 - Mobile RS105 Test System < 50kV/m, 50 cm Height
NEMP140 - Mobile RS105 Test System < 50kV/m, 140 cm Height
NEMPxxxx-O - Outdoor Permanent RS105 Test Systems < 50kV/m, Different standard sizes
NEMP360 - Mobile RS105 Test System >50kV/m, 360 cm Height
NEMP500 - Mobile RS105 Test System >50kV/m, 500 cm Height
NEMP730 - Mobile RS105 Test System >50kV/m, 7.3 m Height
PG1275E - MIL-STD-1275E Surge/Spike Test Generator
NEMP110-G - GTEM RS105 Test System >50kV/m
HPD1000- Outdoor horizontally polarized NEMP simulator 10 m Height
PGR-10KV-50R, 10kV, 5ns rise/fall, Repetitive high voltage pulser