Langer A200 Analog Optical Fiber Probes | DC to 500 kHz

Langer A200 Analog Optical Fiber Probes | DC to 500 kHz

Langer A300 Analog Optical Fiber Probes | DC to 5 MHz

Langer A300 Analog Optical Fiber Probes | DC to 5 MHz

Langer OSE Digital Optical Fiber Probes | 1, 2 and 4 Channels

Langer OSE Digital Optical Fiber Probes | 1, 2 and 4 Channels

Langer CAN 100 Set | Optical CAN Bus Transmission

Langer CAN 100 Set | Optical CAN Bus Transmission

Langer LIN 100 Set | Optical LIN Bus Transmission

Langer LIN 100 Set | Optical LIN Bus Transmission

Langer OB 100 Set | CAN and LIN Opto-Box

Langer OB 100 Set | CAN and LIN Opto-Box

Products

Langer A200 Analog Optical Fiber Probes | DC to 500 kHz

DC to 500 kHz | 1 or 2 analog channels | 3 Msps / 12 bit | 0 to 10 V / 0 to 50 V

Langer A200 optical fiber probe sets monitor DUT waveforms during EFT, ESD and RF immunity testing. The included sensor and receiver transmit signals over fiber for display on an oscilloscope. Choose one channel with 1.5 m fiber or two channels with two 6 m fibers. Supported fiber length is 1 to 20 m.

Langer A300 Analog Optical Fiber Probes | DC to 5 MHz

DC to 5 MHz | 1 or 2 analog channels | 12.5 Msps / 10 bit | +/-10 V

Langer A300 optical fiber probe sets monitor DUT waveforms during EFT, ESD and RF immunity testing. The included sensor and receiver transmit signals over fiber for display on an oscilloscope. Choose one channel with 1.5 m fiber or two channels with two 6 m fibers. Supported fiber length is 1 to 20 m.

Langer OSE Digital Optical Fiber Probes | 1, 2 and 4 Channels

DC to 50 Mbps | 1, 2 or 4 digital channels | S25 sensors | 5 V HCMOS BNC outputs

Compare OSE 150-1, OSE 150-2 and OSE 450 optical transmission sets for observing logic signals during EMC immunity testing. S25 sensor supply is 3 to 5 V at 30 mA. OSE 150 sets use individual OE 150 receivers; OSE 450 uses a single four-channel OE 450 receiver.

Langer CAN 100 Set | Optical CAN Bus Transmission

CAN | Bidirectional optical transmission | 5 V supply

CAN 100 Set supports isolated bus connections for EMC testing. 10 m maximum; 6 m at 1 Mbit/s fiber limit. Includes Double 10 m optical fiber. See the specifications for the individual module supply and operating conditions.

Langer LIN 100 Set | Optical LIN Bus Transmission

LIN | Bidirectional optical transmission | 8 to 15 V master; 8 to 30 V slave

LIN 100 Set supports isolated bus connections for EMC testing. Up to 20 m fiber limit. Includes Double 10 m optical fiber. See the specifications for the individual module supply and operating conditions.

Langer OB 100 Set | CAN and LIN Opto-Box

CAN / LIN | Bidirectional optical transmission | 12 V supply; max. 25 V

OB 100 Set supports isolated bus connections for EMC testing. 20 m; 6 m at 1 Mbit/s CAN fiber limit. Includes Double 10 m optical fiber. See the specifications for the individual module supply and operating conditions.


Loading...